Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

P-L net OXPHOS capacity

From Bioblast


high-resolution terminology - matching measurements at high-resolution


P-L net OXPHOS capacity

Description

Free OXPHOS capacity The free OXPHOS capacity, โ‰ˆP, is the OXPHOS capacity corrected for LEAK respiration, โ‰ˆP = P-L. โ‰ˆP is the scope for ADP stimulation, the respiratory capacity potentially available for phosphorylation of ADP to ATP. Oxygen consumption in the OXPHOS state, therefore, is partitioned into the free OXPHOS capacity, โ‰ˆP, strictly coupled to phosphorylation, ~P, and nonphosphorylating LEAK respiration, LP, compensating for proton leaks, slip and cation cycling: P = โ‰ˆP+LP. It is frequently assumed that LEAK respiration, L, as measured in the LEAK state, overestimates the LEAK component of respiration, LP, as measured in the OXPHOS state, particularly if the protonmotive force is not adjusted to equivalent levels in L and LP. However, if the LEAK component increases with enzyme turnover during P, the low enzyme turnover during L may counteract the effect of the higher ฮ”pmt.

Abbreviation: โ‰ˆP

Reference: Gnaiger 2020 MitoPathways


MitoPedia concepts: Respiratory state, Recommended 





MitoPedia topics: EAGLE 

Communicated by Gnaiger E 2014-08-09, edited 2015-01-19.

Coupling control states for โ‰ˆP

ยป Respiratory state


Flux control factor

ยป Flux control factor, FCF


Compare

Free ET capacity Free ET capacity, โ‰ˆE = E-L
netOXPHOS control ratio netOXPHOS control ratio, โ‰ˆP/E control ratio: โ‰ˆP/E = (P-L)/E
ET-coupling efficiency ET-coupling efficiency, E-L control factor: jโ‰ˆE = โ‰ˆE/E = (E-L)/E = 1-L/E