Difference between revisions of "MiPNet14.06 Instrumental O2 background"

From Bioblast
(Undo revision 187763 by Antunes Diana (talk))
Line 6: Line 6:
|year=2018-08-07
|year=2018-08-07
|journal=Mitochondr Physiol Network
|journal=Mitochondr Physiol Network
|abstract='''Fasching M, Gnaiger E (2018) O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux. Mitochondr Physiol Network 14.6(07):1-14.'''
|abstract=Fasching M, Gnaiger E (2018) O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux. Mitochondr Physiol Network 14.6(07):1-14.
{{MiPNet pdf page linking to MitoPedia}}


:Β» Product: [[O2k-FluoRespirometer]], [[Oroboros O2k-Catalogue |O2k-Catalogue]]
:Β» Product: [[O2k-FluoRespirometer]], [[Oroboros O2k-Catalogue |O2k-Catalogue]]
:Β» MitoPedia: [[Instrumental_background_oxygen_flux| Instrumental background oxygen flux]]
:Β» MitoPedia: [[Instrumental_background_oxygen_flux| Instrumental background oxygen flux]]
|keywords=Instrumental O2 background
|keywords=Instrumental O2 background
Line 14: Line 16:
}}
}}
{{MitoPedia without banner
{{MitoPedia without banner
|abbr=BG
|description=The '''instrumental O<sub>2</sub> background test''' is part 2 of O2k Quality Control, performed after [[MiPNet06.03 POS-calibration-SOP |air calibration of the oxygen sensor]] when starting an experimental series, and performed at intervals of several weeks, depending on the rogorosity of quality control required in an experimental programme.
|info=
}}
__TOC__
{{Technical support integrated}}
::: '''O2k-Protocols SOP'''
:::: Correction for instrumental background oxygen flux is a standard in high-resolution respirometry, automatically performed by DatLab. Background measurements provide a test of instrument function. In the Oroboros O2k, background corrections are usually within a few % of experimental flux over the entire experimental oxygen range. At minimum activities, however, even the small background effects become highly significant and require compliance to standard operating procedures described in this chapter as part of the [[MitoFit Quality Control System]]. This is part 2 of O2k Quality Control.
:Β» O2k Quality Control 1 Β»[[MiPNet06.03 POS-calibration-SOP]]Β«


{{Labeling
{{Labeling

Revision as of 11:31, 13 November 2019

                



MiPNet14.06 Instrumental O2 background

Publications in the MiPMap
O2k-Protocols
O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux.

Β» Bioblast pdf Β» Versions

Oroboros (2018-08-07) Mitochondr Physiol Network

Abstract: Fasching M, Gnaiger E (2018) O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux. Mitochondr Physiol Network 14.6(07):1-14.

O2k-technical support and open innovation
Open the pdf document above.
Β» Current O2k-series: NextGen-O2k Series XB and O2k Series J
Β» Current software versions DatLab 8.0: MitoPedia: DatLab
Β» Product: O2k-FluoRespirometer, O2k-Catalogue
Β» MitoPedia: Instrumental background oxygen flux

β€’ Keywords: Instrumental O2 background

β€’ O2k-Network Lab: AT_Innsbruck_Oroboros

{{MitoPedia without banner


Labels: MiParea: Respiration, Instruments;methods 





HRR: Oxygraph-2k, O2k-Manual 

DatLab, O2k-SOP