Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "MiPNet15.03 O2k-MultiSensor-ISE"

From Bioblast
Line 14: Line 14:
}}
}}
{{Technical support integrated}}
{{Technical support integrated}}
::::» ::::» [[Tetraphenylphosphonium#O2k-technical_support |TPP: O2k-technical_support mt-membrane potential]]
::::» [[Tetraphenylphosphonium#O2k-technical_support |TPP: O2k-technical_support mt-membrane potential]]
::::» [[Calcium#O2k-technical_support |Calcium: O2k-technical_support]]
::::» [[Calcium#O2k-technical_support |Calcium: O2k-technical_support]]
::::» Other ions beside TPP+ TPMP+, and Ca2+: There are ion selective membranes available, e.g. from Sigma Aldrich, for a wide variety of species. If cut to a circle with a diameter of 4 mm these membranes can be used in the ISE system. Many ions may also be detected by fluorimetric based methods.
::::» Other ions beside TPP+ TPMP+, and Ca2+: There are ion selective membranes available, e.g. from Sigma Aldrich, for a wide variety of species. If cut to a circle with a diameter of 4 mm these membranes can be used in the ISE system. Many ions may also be detected by fluorimetric based methods.

Revision as of 18:09, 8 September 2018

                



MiPNet15.03 O2k-MultiSensor-ISE

Publications in the MiPMap
O2k-Manual
O2k-MultiSensor system with ion selective electrodes (ISE).

» Bioblast pdf »Versions

Oroboros (2014-03-06) Mitochondr Physiol Network

Abstract: Fasching M, Gnaiger E (2014) O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr Physiol Network 15.03(05):1-20. -

O2k-Manual: The ion selective electrode (ISE) is a modular O2k-MultiSensor extension of the Oroboros O2k. ISE yield a potentiometric (voltage) signal simultaneously with the oxygen signal in both chambers of the O2k. The ISE system consists of separate reference and measuring electrodes selective for hydrophobic cations (TPP+, TPMP+), Ca2+, Mg2+, etc. This O2k-Manual describes the handling and application of the ISE system.

» Product: O2k-TPP+ ISE-Module, Oroboros O2k-Catalogue

Keywords: HRR, O2k-MultiSensor

O2k-Network Lab: AT_Innsbruck_Oroboros


Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



» TPP: O2k-technical_support mt-membrane potential
» Calcium: O2k-technical_support
» Other ions beside TPP+ TPMP+, and Ca2+: There are ion selective membranes available, e.g. from Sigma Aldrich, for a wide variety of species. If cut to a circle with a diameter of 4 mm these membranes can be used in the ISE system. Many ions may also be detected by fluorimetric based methods.


Labels: MiParea: Instruments;methods 





HRR: Oxygraph-2k, TPP, O2k-Manual, O2k-Protocol 

O2k-MultiSensor, DatLab, DL6, DL7, DL6a7