Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "P-L control efficiency"

From Bioblast
(Created page with "{{MitoPedia |abbr=''CCC<sub>P-L</sub>'' , Ξ”''j<sub>P-L</sub>'' |description=The '''''P-L'' coupling control capacity''', Ξ”''j<sub>P-L</sub>'', is related to the '''respiratory...")
Β 
Line 2: Line 2:
|abbr=''CCC<sub>P-L</sub>'' , Ξ”''j<sub>P-L</sub>''
|abbr=''CCC<sub>P-L</sub>'' , Ξ”''j<sub>P-L</sub>''
|description=The '''''P-L'' coupling control capacity''',Β  Ξ”''j<sub>P-L</sub>'', is related to the '''respiratory control ratio''', RCR, if [[State 3]] is equivalent to the [[OXPHOS]] state, measured at saturating [ADP]; Ξ”''j<sub>P-L</sub>'' is 1.0 for a fully coupled System (when RCR approaches infinity), and is 0.0 for a system with zero [[DT-phosphorylation capacity]] (when ''L''<''E'') or a fully uncoupled system (when ''L''=''P''=''E''; and RCR=1).
|description=The '''''P-L'' coupling control capacity''',Β  Ξ”''j<sub>P-L</sub>'', is related to the '''respiratory control ratio''', RCR, if [[State 3]] is equivalent to the [[OXPHOS]] state, measured at saturating [ADP]; Ξ”''j<sub>P-L</sub>'' is 1.0 for a fully coupled System (when RCR approaches infinity), and is 0.0 for a system with zero [[DT-phosphorylation capacity]] (when ''L''<''E'') or a fully uncoupled system (when ''L''=''P''=''E''; and RCR=1).
|info=[[Gnaiger 2013 Abstract MiP2013]]
|info=[[Flux control capacity]]
}}
}}
{{MitoPedia methods
{{MitoPedia methods

Revision as of 07:13, 5 August 2013


high-resolution terminology - matching measurements at high-resolution


P-L control efficiency

Description

The P-L coupling control capacity, Ξ”jP-L, is related to the respiratory control ratio, RCR, if State 3 is equivalent to the OXPHOS state, measured at saturating [ADP]; Ξ”jP-L is 1.0 for a fully coupled System (when RCR approaches infinity), and is 0.0 for a system with zero DT-phosphorylation capacity (when L<E) or a fully uncoupled system (when L=P=E; and RCR=1).

Abbreviation: CCCP-L , Ξ”jP-L

Reference: Flux control capacity


MitoPedia methods: Respirometry 


MitoPedia topics: "Respiratory control ratio" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property. Respiratory control ratio"Respiratory control ratio" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property. 

Compare