Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Template:Next oroboros ecosystem agenda"

From Bioblast
Line 41: Line 41:
In experiments with pfi, high oxygen concentrations are needed to avoid oxygen limitation . However, the high oxygen pressures used may artificially increase ROS, including H<sub>2</sub>O<sub>2</sub> production, making pfi a less optimal model for ROS production studies. <br>
In experiments with pfi, high oxygen concentrations are needed to avoid oxygen limitation . However, the high oxygen pressures used may artificially increase ROS, including H<sub>2</sub>O<sub>2</sub> production, making pfi a less optimal model for ROS production studies. <br>
- »'''[[Permeabilized_muscle_fibers#Oxygen_dependence_of_ROS_production_-_are_permeabilized_fibers_a_valid_model.3F|Oxygen dependence of ROS production in pfi]]'''«
- »'''[[Permeabilized_muscle_fibers#Oxygen_dependence_of_ROS_production_-_are_permeabilized_fibers_a_valid_model.3F|Oxygen dependence of ROS production in pfi]]'''«
- communicated by »[[Komlodi Timea]]« and »[[Cardoso Luiza]]«
|}
|}
- communicated by »[[Komlodi Timea]]« and »[[Cardoso Luiza]]«
 
----
----
* '''Sep-15 Tu'''
* '''Sep-15 Tu'''

Revision as of 16:20, 3 September 2020

2020 Week 37
  • Sep-07 Mo
O2k-Open Support Take care Why it is necessary to perform multiple H2O2 calibrations when using the Amplex UltraRed (AmR) assay?

The sensitivity to H2O2 of the Amplex UltraRed assay changes during the experiment, thus requires multiple calibrations. These sensitivity changes may be the function of: 1) experimental time, 2) changes in the optical properties of the respiration medium due to sample/chemical titration, 3) the radical scavenging capacity of the sample, and 4) the concentration of accumulating resorufin (UltroxRed in the case of Amplex UltraRed). Therefore, it is recommended to perform H2O2 calibration before sample addition, after sample addition and multiple times during the experiment.
- »Komlodi 2018 Methods Mol Biol« 

The DLPs for AmR SUIT protocols already come with multiple steps of H2O2 calibrations implemented.
- » SUITbrowser« 
- communicated by »Komlodi Timea« and »Cardoso Luiza«


  • Sep-08 Tu

  • Sep-09 We

  • Sep-10 Th
MitoPedia
What is the limitation of State 3 respiration compared to OXPHOS capacity?

OXPHOS capacity is defined as the maximal respiratory capacity in the OXPHOS state in the presence of kinetically-saturating concentration of ADP, Pi, fuel substrates and O2. However, State 3 as defined by Chance and Williams (1955) can lead to underestimation of OXPHOS capacity and overestimation of excess E-P capacity due to kinetic limitations of the phosphorylation system.
- »BEC: Mitochondrial physiology« - Table 3 and several figures.
- communicated by » Cecatto Cristiane « and » Komlodi Timea «



  • Sep-11 Fr


2020 Week 38
  • Sep-14 Mo
MitoPedia
Why are permeabilized muscle fibers (pfi) a poor sample type for studying reactive oxygen species (ROS) production?

In experiments with pfi, high oxygen concentrations are needed to avoid oxygen limitation . However, the high oxygen pressures used may artificially increase ROS, including H2O2 production, making pfi a less optimal model for ROS production studies.
- »Oxygen dependence of ROS production in pfi« - communicated by »Komlodi Timea« and »Cardoso Luiza«


  • Sep-15 Tu

  • Sep-16 We

  • Sep-17 Th
MitoPedia: SUIT Did you know that you can measure the respiratory activity available for phosphorylation of ADP to ATP in living cells?

SUIT protocols from the SUIT-003 family will guide you through the titrations needed to analyse free ROUTINE activity.
- »SUIT-003 O2 ce D009« and »SUIT-003 O2 ce-pce D020« 
- communicated by »Cardoso Luiza« and »Komlodi Timea«


  • Sep-18 Fr

  • Sep-19 Sa

  • Sep-20 So

2020 Week 39
  • Sep-21 Mo
ÖGMBT Graz AT 12th ÖGMBT Annual Meeting 2020 Graz AT Sep 21-23
MitoPedia: SUIT Did you know the reverse electron flow from Complex II to Complex I can be investigated in mitochondrial preparations by measuring hydrogen peroxide production using Amplex UltraRed assay?

The reverse electron flow, also called reverse electron transfer (RET), happens when electrons are transferred from Complex II to the Q-junction and then back to Complex I at high mt-membrane potential. This phenomenon results in high hydrogen peroxide production in some mitochondrial preparations. The SUIT-026 protocol was designed to investigate this effect.
- »SUIT-026« 
- communicated by »Komlodi Timea« and »Cardoso Luiza« 




  • Sep-24 Th

  • Sep-25 Fr
2020 Week 40
  • Sep-28 Mo

  • Sep-29 Tu

  • Sep-30 We

  • Oct-01 Th

  • Oct-02 Fr

  • Oct-03 Sa
2020 Week 41
  • Oct-05 Mo

  • Oct-06 Tu

  • Oct-07 We
O2k-Workshops Pre-Conference O2k-Workshop »MiPNet25.11 IOC148 Riga LV «
EU-CARDIOPROTECTION »6th EU-Cardioprotection Meeting 2020 Riga LV« (Oct 7-9)


»Long Night of Research 2020 Innsbruck AT«
2020 Week 42
  • Oct-12 Mo
FAT4BRAIN »FAT4BRAIN School IOC147 Riga LV« (Oct 7-9)

  • Oct-13 Tu
FAT4BRAIN School IOC147 Riga LV

  • Oct-14 We

  • Oct-15 Th

  • Oct-16 Fr

  • Oct-18 Su
»ISCaM 2020 London UK«
2020 Week 43


  • Oct-21 We

  • Oct-22 Th

  • Oct-23 Fr
2020 Week 44
  • Oct-26 Mo

  • Oct-27 Tu

  • Oct-28 We

  • Oct-29 Th

  • Oct-30 Fr
2020 Week 45
  • Nov-02 Mo

  • Nov-03 Tu

  • Nov-04 We
COST Action MitoEAGLE MitoEAGLE Summit Obergurgl 2020


2020 Week 46
  • Nov-09 Mo
COST Action MitoEAGLE MiPschool Obergurgl 2020 including TRANSMIT School 2020



  • Nov-12 Th

  • Nov-13 Fr
2020 Week 47
  • Nov-16 Mo

  • Nov-17 Tu

  • Nov-18 We
link=https://wiki.oroboros.at/index.php/Asia_Society_for_Mitochondrial_Research_and_Medicine ASMRMASMRM 2020 Singapore SG

  • Nov-19 Th
link=https://wiki.oroboros.at/index.php/Asia_Society_for_Mitochondrial_Research_and_Medicine ASMRMASMRM 2020 Singapore SG

  • Nov-20 Fr
link=https://wiki.oroboros.at/index.php/Asia_Society_for_Mitochondrial_Research_and_Medicine ASMRMASMRM 2020 Singapore SG
2020 Week 48
  • Nov-23 Mo

  • Nov-24 Tu

  • Nov-25 We
» 2020Spring PaduaMuscleDays Padova IT / O2k-Workshops IOC Padua IT - separate registration

  • Nov-26 Th
2020Spring PaduaMuscleDays Padova IT

  • Nov-27 Fr
2020Spring PaduaMuscleDays Padova IT

  • Nov-28 Sa
2020Spring PaduaMuscleDays Padova IT
2020 Week 49
  • Nov-30 Mo

  • Dec-01 Tu
AlgaeEurope AlgaEurope 2020 Rome IT

  • Dec-02 We

  • Dec-03 Th

  • Dec-04 Fr

  • Dec-05 Sa

  • Dec-06 So

2020 Week 50
  • Dec-07 Mo

  • Dec-08 Tu

  • Dec-09 We
ESSR2020 ESSR 2020 Innsbruck AT (Dec 9-11)

  • Dec-10 Th

  • Dec-11 Fr
2020 Week 51
  • Dec-14 Mo

  • Dec-15 Tu

  • Dec-16 We

  • Dec-17 Th

  • Dec-18 Fr
2020 Week 52
  • Dec-21 Mo

  • Dec-22 Tu

  • Dec-23 We

  • Dec-24 Th

  • Dec-25 Fr
2020 Week 53
  • Dec-28 Mo

  • Dec-29 Tu

  • Dec-30 We

  • Dec-31 Th

  • Jan-01 Fr