MiPNet15.03 O2k-MultiSensor-ISE: Difference between revisions

From Bioblast
No edit summary
No edit summary
Line 6: Line 6:
|year=2018-01-25
|year=2018-01-25
|journal=Mitochondr Physiol Network
|journal=Mitochondr Physiol Network
|abstract='''Fasching M, Gnaiger E (2018) O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr Physiol Network 15.03(08):1-26.''' - ย 
|abstract=Fasching M, Gnaiger E (2018) O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr Physiol Network 15.03(08):1-26. -
ย 
{{MiPNet pdf page linking to MitoPedia}}
'''O2k-Manual''': The ion selective electrode (ISE) is a modular O2k-MultiSensor extension of the Oroboros O2k. ISE yield a potentiometric (voltage) signal simultaneously with the oxygen signal in both chambers of the O2k. The ISE system consists of separate reference and measuring electrodes selective for hydrophobic cations (TPP<sup>+</sup>, TPMP<sup>+</sup>), Ca<sup>2+</sup>, Mg<sup>2+</sup>, etc. This O2k-Manual describes the handling and application of the ISE system.
:ยป Product: [[O2k-TPP+ ISE-Module]], [[Oroboros O2k-Catalogue]]
:ยป Product: [[O2k-TPP+ ISE-Module]], [[Oroboros O2k-Catalogue]]
|keywords=[[HRR]], [[O2k-MultiSensor]]
|mipnetlab=AT_Innsbruck_Oroboros
|mipnetlab=AT_Innsbruck_Oroboros
}}
}}
{{MitoPedia without banner
|abbr=
|description='''Ion selective electrodes (ISE)''' are components of O2k-MultiSensor-ISE Modules for measurement of mt-membrane potential (TPP<sup>+</sup>; [[safranin]]), [[calcium]], or [[pH]] simulaneously with O<sub>2</sub> concentration and respiration.
|info=
}}
__TOC__
{{Technical support integrated}}
::::ยป [[Tetraphenylphosphonium#O2k-technical_support |TPP: O2k-technical_support mt-membrane potential]]
::::ยป [[Calcium#O2k-technical_support |Calcium: O2k-technical_support]]
::::ยป Other ions beside TPP<sup>+</sup>, TPMP<sup>+</sup>, and Ca<sup>2+</sup>: There are ion selective membranes available, ''e.g.'', from Sigma Aldrich, for a wide variety of ionic species. If cut to a circle with a diameter of 4 mm these membranes can be used in the ISE system. Many ions may also be detected by fluorimetric based methods.
== Keywords: Force and membrane potential ==
{{Keywords Force and membrane potential}}


{{Labeling
{{Labeling

Revision as of 11:01, 14 November 2019

                



MiPNet15.03 O2k-MultiSensor-ISE

Publications in the MiPMap
O2k-Manual
O2k-MultiSensor system with ion selective electrodes (ISE).

ยป Bioblast pdf ยปVersions

Oroboros (2018-01-25) Mitochondr Physiol Network

Abstract: Fasching M, Gnaiger E (2018) O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr Physiol Network 15.03(08):1-26. -

O2k-technical support and open innovation
Open the pdf document above.
ยป Current O2k-series: NextGen-O2k Series XB and O2k Series J
ยป Current software versions DatLab 8.0: MitoPedia: DatLab
ยป Product: O2k-TPP+ ISE-Module, Oroboros O2k-Catalogue


โ€ข O2k-Network Lab: AT_Innsbruck_Oroboros


Labels: MiParea: Instruments;methods 





HRR: Oxygraph-2k, TPP, O2k-Manual 

O2k-MultiSensor, DatLab, DL6, DL6a7 

Cookies help us deliver our services. By using our services, you agree to our use of cookies.