Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Search results

From Bioblast
Results 1 – 52 of 52
Advanced search

Search in namespaces:

  
  
  
  
  
  
  
  
  
  
  
  
  
  • === Part 1.1: OroboPOS service and O2k instrumental set up === ...s://www.youtube.com/watch?v=wMDcSypG3O4&feature=youtu.be O2k-Videosupport: OroboPOS]
    2 KB (316 words) - 10:04, 29 March 2024
  • ...rer-Bar\white PVDF\15x6 mm|PVDF Stirrer-Bars]], 2 [[PEEK]] O2k-Stoppers, [[OroboPOS-Connector]]s for O2k-series A-I and NextGen-O2k series XA (attached to the
    692 bytes (97 words) - 15:47, 9 August 2023
  • ...ight|180px]]'''OroboPOS-Connector''' (blue POM), with male connection to [[OroboPOS]] head (POS) and with cable and male plug fitting into [[O2k-Main Unit]]. |info=[https://www.oroboros.at/index.php/product/orobopos-connector/ '''Product details and purchase information''']
    4 KB (681 words) - 11:14, 10 November 2023
  • ...on]], [[OroboPOS-Connector_MitoPedia#Cleaning_the_electrical_connections | OroboPOS-Connector]] ::::# Unplug the [[POS-Connector]] from the O2k-main unit and unscrew the [[OroboPOS]] from the [[POS-Connector]]. Screw the POS to the blue part of the perspex
    5 KB (764 words) - 10:47, 5 April 2024
  • ...####''' '''[[Oroboros O2k]]''' / '''[[O2k-Catalogue: OroboPOS components|OroboPOS]]'''
    1 KB (150 words) - 14:14, 21 July 2020
  • ...b>2</sub>S<sub>2</sub>O<sub>4</sub>), for zero-oxygen calibration of the [[OroboPOS]].
    700 bytes (88 words) - 15:51, 18 January 2022
  • *Copper-Block with windows to 2 O2k-Chambers *2 Amperometric OroboPOS Plugs
    821 bytes (121 words) - 12:07, 14 April 2021
  • ...the [[OroboPOS|POS]] to the 2-mL [[O2k-chamber]], and keeping the SmartPOS/OroboPOS-Connector in a fixed position for sealing the O2k-chamber with the [[POS-Se |info=[https://www.oroboros.at/index.php/product/orobopos-holder/ '''Product details and purchase information''']
    2 KB (351 words) - 11:13, 27 July 2023
  • |abbr=H<sub>2</sub>O ...iH<sub>2</sub>O) with various combination purification methods. When H<sub>2</sub>O is mentioned without further specification in published protocols, i
    1 KB (167 words) - 10:40, 18 February 2016
  • |description=The 2-chamber design of the O2k helps to '''search for defective O2k components'' ::#[https://www.youtube.com/watch?v=ju-qZ2sz5ro how to disassemble the OroboPos ]
    538 bytes (79 words) - 09:57, 5 March 2021
  • ...omponent of [[MitoPedia: Oroboros QM |Oroboros Quality Management]]. The [[OroboPOS]] test is described in detail in [[MiPNet06.03 POS-calibration-SOP]], is pe ::::The O2 sensor test does not only serve to evaluate the function of the OroboPOS, but many other components of the O2k have to function according to specifi
    10 KB (1,476 words) - 09:52, 5 April 2024
  • ...tube.com/watch?v=9TYfEAz96Lc&list=PLT4umseflf-m6O1sApyn9doi8vHNAKaIs&index=2&t=0s O2k ready to use] ...Gzb0KfYwTQ&list=PLT4umseflf-m6O1sApyn9doi8vHNAKaIs&index=4 '''A3''' Insert OroboPOS]
    9 KB (1,435 words) - 12:42, 14 November 2023
  • === Part 1.1: OroboPOS service and O2k instrumental === ...s://youtu.be/wMDcSypG3O4]] [https://youtu.be/wMDcSypG3O4 O2k-Videosupport: OroboPOS from Perspex housing]
    5 KB (754 words) - 12:50, 7 November 2023
  • ...ressure and electric current [Amp] (amperometric mode of operation). The [[OroboPOS]] is the POS applied in the [[Oroboros O2k]]. |info=[[OroboPOS]]
    6 KB (814 words) - 14:34, 8 August 2023
  • ...brane application. Since the O2k-Series G-0075 membrane ring holder have a 2 mm extended ridge for a better grip. |info=[https://www.oroboros.at/index.php/product/orobopos-mounting-tool/ '''Product details and purchase information''']
    874 bytes (115 words) - 11:36, 25 July 2023
  • :::: The '''O<sub>2</sub> sensor and O2k chamber tests''' are important to eliminate instrument === 1. O<sub>2</sub> sensor test ===
    4 KB (599 words) - 16:43, 9 August 2022
  • ...k]] is transmitted from the electrochemical polarographic oxygen sensor ([[OroboPOS]]) for each of the two O2k-chambers to [[DatLab]]. The primary signal is a ...[µM], but the numbers shown as a default are different from the real O<sub>2</sub> concentration. The non-calibrated default values are calculated on th
    9 KB (1,446 words) - 11:18, 9 April 2024
  • ::::* When a new [[OroboPOS-Connector]] is used. ...as % of the raw signal at air saturation. New POS have a zero signal below 2 % of the signal at air saturation. For accurate calibration, the zero signa
    3 KB (502 words) - 10:20, 5 April 2024
  • ...roboPOS]]. Two [[O2k-Chamber Holder]]s, two [[OroboPOS-Holder]]s and two [[OroboPOS-Connector]]s are attached to the O2k-Main Unit for transport. ...PNet22.11_O2k-FluoRespirometer_manual]]) and store the O2k-Chambers in the OroboPOS-Service Kit box.
    7 KB (1,045 words) - 13:07, 9 November 2023
  • ...us medium and ensure a stable signal of the polarographic oxygen sensor ([[OroboPOS]]) placed in a position of maximum current of the medium.
    1 KB (170 words) - 17:59, 15 March 2023
  • ...right|180px]]'''Volume-Calibration Ring''' (A or B) PVDF for O2k-Stoppers (2-mL [[O2k-chamber]]), white; attached to the [[Stopper\black PEEK\conical Sh ::::* Loosen the stopper fixation rings (A) and (B) with the Allen key (OroboPOS-Service Kit).
    1 KB (171 words) - 11:53, 11 November 2020
  • ...(O2k Quality Control)]] for the [[O2k-Open_Support#1._O2_sensor_test|O<sub>2</sub> sensor test]], the stirrer test is performed in the 'open' chamber in
    1 KB (227 words) - 11:42, 6 May 2024
  • |description=What are potential causes for '''different O<sub>2</sub> fluxes in the left and right chamber'''? ...ocedure described in the section '''Calibration and quality control of the OroboPOS (O2k-SOP)''' in [[O2_calibration_-_DatLab#Calibration_and_quality_control|
    2 KB (341 words) - 18:56, 6 November 2019
  • ...mber''': Duran® glass polished, with standard operation volumes (''V'') of 2.0 mL or 0.5 mL (small chamber volume in the [[O2k-sV-Module]], 12 mm inner ...''' - [https://www.oroboros.at/index.php/product/o2k-chamber/ O2k-Chamber (2.0 mL)], [https://www.oroboros.at/index.php/product/o2k-chamber-sv/ O2k-Cham
    12 KB (1,709 words) - 13:03, 5 February 2024
  • ...esolution respirometry with the Oroboros O2k. Hands-on sessions range from OroboPOS technical service to respirometry experiments with substrate-uncoupler-inhi |OroboPOS service and O2k instrumental setup - overview with videoclips
    8 KB (952 words) - 15:45, 8 June 2020
  • ...tatus line|status line]], besides the DatLab version number (bottom), and (2) in windows [[O2k control]] [F7] and [[O2k configuration]]. ::::* Type of [[OroboPOS-Connector]]
    2 KB (373 words) - 08:50, 11 November 2019
  • ::::::::''16:30 - 17:15'' O2k setup (team 1 and 2); OroboPOS service (team 3 and 4) ...17:15 - 18:00'' O2k setup (team 3 and 4); OroboPOS service (team 1 and 2)
    7 KB (787 words) - 10:32, 11 April 2022
  • == Electrochemical NO and H<sub>2</sub>O<sub>2</sub> sensors == ...sensors. All amperometric sensors (NO, H<sub>2</sub>S, H<sub>2</sub>O<sub>2</sub>) that have the same connection can be used with the O2k.
    6 KB (883 words) - 11:50, 17 August 2022
  • ...k-Fluorometry for measurement of hydrogen peroxide, ATP production, Ca<sup>2+</sup> uptake capacity, mitochondrial membrane potential with fluorometric ...ality controls 1 ([[MiPNet06.03 POS-calibration-SOP |O2 sensor test]]) and 2 ([[MiPNet14.06 Instrumental O2 background |O2k-chamber test]]), which are e
    5 KB (667 words) - 14:56, 11 July 2022
  • ...you know that you can set a warning alarm for the lower limit of the O<sub>2</sub> concentration in DatLab 7? '''<br> - »[[Run_DL-Protocol/Set_O2_limit#Protocol_menu | '''Set O<sub>2</sub> limit in DatLab''']]« <br>
    27 KB (4,026 words) - 11:53, 29 March 2021
  • |Introduction - OroboPOS service and O2k instrumental setup - overview with videoclips |Hands-on: OroboPOS service and O2k instrumental setup
    6 KB (698 words) - 15:40, 8 June 2020
  • |OroboPOS service and O2k instrumental setup - overview with videoclips |'''Hands-on''': OroboPOS service and O2k instrumental setup
    6 KB (750 words) - 10:56, 31 March 2021
  • ...esolution respirometry with the Oroboros O2k. Hands-on sessions range from OroboPOS technical service to respirometry experiments with substrate-uncoupler-inhi |2.77
    11 KB (1,464 words) - 15:47, 8 June 2020
  • [[File:Distributor training 2.jpeg|500px|right|Distributor training]] :::: 16:00 - 17:00 General questions (OroboPOS-Connector, quality control…)
    3 KB (374 words) - 06:27, 13 May 2023
  • ...-wide distibution of the O2k. With completion of the development of DatLab 2 in cooperation with Dr. Michael Reck, the term "high-resolution respirometr ::::In '''[[Oroboros 1997| 1997]]''' Oroboros released DatLab 2, setting a new standard in software-supported high-resolution respirometry.
    8 KB (1,102 words) - 16:18, 22 February 2024
  • ...tration]]s in [[MiPNet14.06 Instrumental O2 background |instrumental O<sub>2</sub> background tests]]. It is not recommended to use dithionite in experi |chem formula=Na<sub>2</sub>S<sub>2</sub>O<sub>4</sub>
    9 KB (1,336 words) - 07:33, 13 October 2023
  • :::: Minimum duration: 2 days ...from instrumental setup and service of the polarographic oxygen sensor ([[OroboPOS]]) for instrumental quality control system, which is an essential component
    4 KB (577 words) - 15:03, 14 September 2021
  • |abbr=''J''°<sub>O<sub>2</sub></sub> ...e range of experimental oxygen levels by a standardized instrumental O<sub>2</sub> background test. The oxygen regime from air saturation towards zero o
    22 KB (3,238 words) - 15:29, 2 May 2024
  • ...oxygen partial pressure at the temperature defined by the experimenter; (''2'') zero oxygen calibration; (''3'') high stability of the POS signal tested ...ring an instrumental calibration run. '''Step <span style="background:red">2</span>''': Click on <span style="background:lightgrey">Calibrate and copy t
    26 KB (3,995 words) - 10:15, 7 October 2021
  • ''' [[OroboPOS| Polarographic oxygen sensor (POS)]] and O2k service''' ...potential ([[Safranin]]), ATP production ([[Magnesium green]]), and Ca<sup>2+</sup> ([[Calcium green]]). Further O2k-MultiSensor applications are covere
    8 KB (1,139 words) - 09:41, 1 June 2023
  • ...s of the Titration-Injection microPump TIP2k. Hands-on sessions range from OroboPOS technical service (instrumental quality control system which is an essentia ...ys prior. Booking requires a credit card for guarantee. Payment on site. A 2 € City tax to be charged additionally.
    7 KB (955 words) - 10:50, 22 November 2021
  • ::::* Instrumental setup, chamber assembly, OroboPOS – sensor service, quality control (group Carmen Sandi). :::: Design of experimental protocol - day 2.
    7 KB (850 words) - 15:13, 8 June 2020
  • ...oduction of the Oroboros O2k was preceeded by instrumental developments [1,2] including the Twin-Flow Microrespirometer [3] for simultaneous application ...solution respirometry [9-12]. With completion of the development of DatLab 2 Dr. Michael Reck), the term "high-resolution respirometry" [HRR] was coined
    7 KB (1,003 words) - 05:51, 5 July 2022
  • ...n of respiratory rate by cell count yields oxygen [[flow]] ''I''<sub>O<sub>2</sub></sub> expressed in units [amol·s<sup>-1</sup>·x<sup>-1</sup>] (=10< ...ibrated experimental volume of ''V''=0.5 mL or 2.0 mL using the 0.5-mL and 2.0-mL chamber, respectively. The corresponding corrections, however, depend
    35 KB (5,607 words) - 16:01, 21 February 2024
  • |''' Why is it important to check the H<sub>2</sub>O<sub>2</sub> sensitivity when conducting an Amplex UltraRed (AmR) assay? ...osition, added chemicals and sample, requiring multiple H<sub>2</sub>O<sub>2</sub> calibrations throughout the measurement. After the initial AmR calibr
    27 KB (4,003 words) - 08:47, 6 May 2024
  • Day 2: SUIT protocol for comparative mitochondrial physiology - a pilot experimen ...ive to the Amazon, and is among the largest freshwater fish in the world (>2.5 m). As an adaptation to the seasonal hypoxic conditions, Arapaima has dev
    13 KB (1,875 words) - 00:16, 12 January 2022
  • File:IOC115 (2).jpg|Full in action: Participants practising O2k applications File:IOC115 (4).jpg|Participants practising the OroboPOS sensor service
    10 KB (1,418 words) - 15:21, 8 June 2020
  • ...nditioning solution 1''' (dissolved in 100 mM KCl solution) for use in '''2-mL O2k-chamber''': ...nditioning solution 2''' (dissolved in 100 mM KCl solution) for use in '''2-mL O2k-chamber''':
    37 KB (5,710 words) - 15:30, 16 May 2023
  • ...cle/view/gnaiger_2020_mitopathways Gnaiger 2020 BEC MitoPathways - Chapter 2.4]« <br> ...ndaries. Therefore, a short-chain, membrane-permeable CoQ mimetic, CoQ<sub>2</sub> is used as a probe which reacts with the mitochondrial respiratory Co
    85 KB (11,819 words) - 14:18, 10 January 2022
  • ...you know that you can set a warning alarm for the lower limit of the O<sub>2</sub> concentration in DatLab 7? '''<br> - » [[Run_DL-Protocol/Set_O2_limit#Protocol_menu | Set O<sub>2</sub> limit]] in DatLab « <br>
    126 KB (17,785 words) - 08:55, 13 August 2021
  • |'''Mountain slopes can be difficult, but O<sub>2</sub> slopes can be smooth with DatLab'''<br> ...ints, corresponding to an interval of 80 s at a data recording interval of 2 s. DatLab 7 expresses it in data points and DatLab 8 in seconds.
    80 KB (11,165 words) - 09:37, 8 January 2024
  • Prepare your TIP2k for Instrumental O<sub>2</sub> background: <br> ...v=VV9pRcK076k O2k-Videosupport: Working with the TIP2k (instrumental O<sub>2</sub> background)]'''«<br>
    87 KB (11,941 words) - 15:14, 16 November 2023