Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Fluorescence-Sensor"

From Bioblast
m
(Redirected page to O2k-Fluo Smart-Module)
ย 
(11 intermediate revisions by 4 users not shown)
Line 1: Line 1:
{{Product
#REDIRECT [[O2k-Fluo Smart-Module]]
|description='''Fluorescence-Sensor''': LED with specified wavelength, photodiode, [[Filter-Cap]] attached with specific optical filter for the LED and/or photodiode. See [[Fluorescence-Sensor Green]] and [[Fluorescence-Sensor Blue]].
|product id=442##
|product type=O2k, MultiSensor, O2k-Fluorescence LED2-Module
|info='''''>> More details? Consult [[O2k-Fluorescence LED2-Module]]'''''
|product image=[[image:Fluorescence-Sensor.jpg|180px|right]]
}}
__TOC__
== O2k-Guide ==
=== Select the Fluorescence-Sensors ===
Switching between different excitation wavelengths and filters is achieved by simply exchanging the fluorescence sensors. Two types of optical sensors are supplied with different LEDs for fluorescence excitation, and the effective spectra of the LEDs are modified by filters.
Please select the necessary fluorescence sensor and filter set form the table ofย  [[MiPNet17.05_O2k-Fluorescence_LED2-Module#Fluorophores|application specific settings]]. Each fluorescence sensor is delivered with a filter set already in place:
# [[Fluorescence-Sensor Green]]: 525 nm. The installed Filter-Cap is ready for H2O2 measurement with [[Amplex red|Amplexยฎ UltraRed]].
# [[Fluorescence-Sensor Blue]]: 465 nm. The installed Filter-Cap is ready for measurements of mt-membrane potential with [[safranin]]. A different filter is used for measurement with [[Magnesium green| Magnesium greenยฎ]] or Calcium greenยฎย  .
ย 
'''O2k-Guide: Setup - next step [[Filter-Cap#Mounting_a_Filter-Cap|Mounting a Filter-Cap]]'''
ย 
[[File:Fluorescence-Control Unit lettered.jpg|400px|right|link=]]
ย 
=== Connect Fluorescence-Sensor to O2k ===
For recording of fluorescence signals, insert the black sensor into the window of the O2k chamber as far as possible, aligning the Sensor-Guide Sector with the Sensor-Guide of the O2k-Front Fixation. Then connect the cable of the Fluorescence-Sensor to the Fluorescence-Sensor Plug of the Fluorescence-Control Unit.
Removing a Fluorescence-Sensor from the O2k chamber: Remove the Sensor-Guide to allow rotation of the sensor. Pull out the Fluorescence-Sensor while rotating it. Do not pull on the cable. Replace the Sensor-Guide.
ย 
=== Stoppers ===
Use only [[Stopper\black PEEK\conical Shaft\central Port|black PEEK stoppers]] in conjunction with fluorometric measurements. If necessary, replace the previous white PVDF stoppers. The black stoppers can be used for all HRR applications in general. See [[MiPNet19.18A_O2k-Start]] for calibration of the O2k-chamber volume, which is identical for PEEK and PVDF stoppers.
ย 
'''O2k-Guide: [[Fluorescence-Control_Unit#O2k-Guide|Electronic settings]]'''
ย 
ย 
[[Category:Technical service]]

Latest revision as of 20:25, 6 November 2019