Lyon 2006 Anal Chem: Difference between revisions

From Bioblast
(Created page with "{{Publication |title=Lyon J L, Stevenson K J (2006) Picomolar peroxide detection using a chemically activated redox mediator and square wave voltammetry. Anal Chem 78: 8518-8525....")
ย 
No edit summary
ย 
Line 1: Line 1:
{{Publication
{{Publication
|title=Lyon J L, Stevenson K J (2006) Picomolar peroxide detection using a chemically activated redox mediator and square wave voltammetry. Anal Chem 78: 8518-8525. ย 
|title=Lyon J L, Stevenson K J (2006) Picomolar peroxide detection using a chemically activated redox mediator and square wave voltammetry. Anal Chem 78:8518-25.
|info=[http://www.ncbi.nlm.nih.gov/pubmed/17165848 PMID: 17165848]
|info=[http://www.ncbi.nlm.nih.gov/pubmed/17165848 PMID: 17165848]
|authors=Lyon J L, Stevenson K J
|authors=Lyon J L, Stevenson K J
Line 10: Line 10:
{{Labeling
{{Labeling
|area=Instruments;methods
|area=Instruments;methods
|injuries=RONS; Oxidative Stress
|injuries=Oxidative stress;RONS
}}
}}

Latest revision as of 16:38, 23 February 2015

Publications in the MiPMap
Lyon J L, Stevenson K J (2006) Picomolar peroxide detection using a chemically activated redox mediator and square wave voltammetry. Anal Chem 78:8518-25.

ยป PMID: 17165848

Lyon J L, Stevenson K J (2006) Anal Chem

Abstract: A method for low-level, low-potential electrochemical detection of hydrogen peroxide using a chemically activated redox mediator is presented. This method is unique in that it utilizes a mediator, Amplex Red, which is only redox-active when chemically oxidized by H2O2 in the presence of the enzyme horseradish peroxidase (HRP). When employed in concert with microelectrode square wave voltammetry to optimize sensing at ultralow concentrations (<1 microM), this method exhibits marked improvements in analytical sensitivity and detection limits (limit of detection as low as 8 pM) over existing protocols. Sensing schemes incorporating both freely diffusing and immobilized HRP are evaluated, and the resulting analytical sensitivities are 1.22 +/- 0.04 and (2.1 +/- 0.6) x 10(-1) microA/(microM mm2), respectively, for peroxide concentrations in the high picomolar to low micromolar range. A second linear region exists for lower peroxide concentrations. Furthermore, quantitative enzyme kinetics analysis using Michaelis-Menten parameters is possible through interpretation of data collected in this scheme. Km values for soluble and immobilized HRP were 84 +/- 13 and 504 +/- 19 microM, respectively. This method is amenable to any biological detection scheme that generates hydrogen peroxide as a reactive product. โ€ข Keywords: Amplex Red


Labels: MiParea: Instruments;methods 

Stress:Oxidative stress;RONS 






Cookies help us deliver our services. By using our services, you agree to our use of cookies.