Difference between revisions of "MiPNet15.03 O2k-MultiSensor-ISE"
Line 1: | Line 1: | ||
{{Publication | {{Publication | ||
|title=Fasching M, Gnaiger E. O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr. Physiol. Network 15.03. | |title=Fasching M, Gnaiger E. O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr. Physiol. Network 15.03. | ||
|info=[http://www.oroboros.at/index.php?id=o2k-multisensor MiPNet15.03] | |||
|authors=Fasching M, Gnaiger E | |authors=Fasching M, Gnaiger E | ||
|year=* | |year=* | ||
|journal=Mitochondr. Physiol. Network | |journal=Mitochondr. Physiol. Network | ||
|abstract=The O2k-MultiSensor extension of the OROBOROS Oxygraph-2k yields a record of a potentiometric (voltage) signal simultaneously to the oxygen signal in both chambers of the O2k. A new ion selective electrode (ISE) system is described here, consisting of separate reference and measuring electrodes. Typical examples are electrodes selective for hydrophobic cations (TPP+, TPMP+), Ca2+, Mg2+, etc. This manual describes the handling and application of this ISE system. | |abstract=The O2k-MultiSensor extension of the OROBOROS Oxygraph-2k yields a record of a potentiometric (voltage) signal simultaneously to the oxygen signal in both chambers of the O2k. A new ion selective electrode (ISE) system is described here, consisting of separate reference and measuring electrodes. Typical examples are electrodes selective for hydrophobic cations (TPP+, TPMP+), Ca2+, Mg2+, etc. This manual describes the handling and application of this ISE system. | ||
|keywords=HRR-MultiS | |keywords=HRR-MultiS | ||
| | |mipnetlab=AT_Innsbruck_OROBOROS | ||
|articletype=Protocol; Manual, MiPNet-online Publication | |||
}} | }} | ||
{{Labeling | {{Labeling | ||
|instruments=Oxygraph-2k, TIP2k, | |instruments=Oxygraph-2k, TIP2k, O2k-Manual, MiPNet-Publication | ||
|articletype=Protocol; Manual, MiPNet-online Publication | |articletype=Protocol; Manual, MiPNet-online Publication | ||
}} | }} | ||
Revision as of 17:36, 13 May 2011
Fasching M, Gnaiger E. O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr. Physiol. Network 15.03. |
Β» MiPNet15.03
) Mitochondr. Physiol. Network
Abstract: The O2k-MultiSensor extension of the OROBOROS Oxygraph-2k yields a record of a potentiometric (voltage) signal simultaneously to the oxygen signal in both chambers of the O2k. A new ion selective electrode (ISE) system is described here, consisting of separate reference and measuring electrodes. Typical examples are electrodes selective for hydrophobic cations (TPP+, TPMP+), Ca2+, Mg2+, etc. This manual describes the handling and application of this ISE system. β’ Keywords: HRR-MultiS
β’ O2k-Network Lab: AT_Innsbruck_OROBOROS
Labels:
HRR: Oxygraph-2k, TIP2k, O2k-Manual, MiPNet-Publication"MiPNet-Publication" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property.