{{Publication | {{Publication | ||
|title=Fasching M, Gnaiger E. O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr | |title=Fasching M, Gnaiger E. O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr Physiol Network 15.03. | ||
|info=[http://www.oroboros.at/index.php?id=o2k-multisensor-manual MipNet15.03] | |info=[http://www.oroboros.at/index.php?id=o2k-multisensor-manual MipNet15.03] | ||
|authors=Fasching M, Gnaiger E | |authors=Fasching M, Gnaiger E | ||
|year=* | |year=* | ||
|journal=Mitochondr | |journal=Mitochondr Physiol Network | ||
|abstract=The O2k-MultiSensor extension of the OROBOROS Oxygraph-2k yields a record of a potentiometric (voltage) signal simultaneously to the oxygen signal in both chambers of the O2k. A new ion selective electrode (ISE) system is described here, consisting of separate reference and measuring electrodes. Typical examples are electrodes selective for hydrophobic cations (TPP+, TPMP+), Ca2+, Mg2+, etc. This manual describes the handling and application of this ISE system. | |abstract=The O2k-MultiSensor extension of the OROBOROS Oxygraph-2k yields a record of a potentiometric (voltage) signal simultaneously to the oxygen signal in both chambers of the O2k. A new ion selective electrode (ISE) system is described here, consisting of separate reference and measuring electrodes. Typical examples are electrodes selective for hydrophobic cations (TPP+, TPMP+), Ca2+, Mg2+, etc. This manual describes the handling and application of this ISE system. | ||
|keywords=HRR, MultiSensor | |keywords=HRR, MultiSensor |
Revision as of 11:39, 22 June 2012
Fasching M, Gnaiger E. O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr Physiol Network 15.03. |
Β» MipNet15.03
Abstract: The O2k-MultiSensor extension of the OROBOROS Oxygraph-2k yields a record of a potentiometric (voltage) signal simultaneously to the oxygen signal in both chambers of the O2k. A new ion selective electrode (ISE) system is described here, consisting of separate reference and measuring electrodes. Typical examples are electrodes selective for hydrophobic cations (TPP+, TPMP+), Ca2+, Mg2+, etc. This manual describes the handling and application of this ISE system. β’ Keywords: HRR, MultiSensor
β’ O2k-Network Lab: AT_Innsbruck_OROBOROS
Labels:
HRR: Oxygraph-2k, TIP2k, TPP, O2k-Manual, Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property., MiPNet-Publication"MiPNet-Publication" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property.
O2k-SOP