Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "MiPNet15.03 O2k-MultiSensor-ISE"

From Bioblast
Line 1: Line 1:
{{Publication
{{Publication
|title=Fasching M, Gnaiger E (2010) O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr Physiol Network 15.03.
|title=Fasching M, Gnaiger E (2010) O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr Physiol Network 15.03.
|info='''Open Access - [[File:MiPNet15.03_MultiSensor-ISE.pdf]]'''
|info=[[Media:MiPNet15.03_MultiSensor-ISE.pdf|'''Open Access-MiPNet15.03.pdf''']]; [http://www.bioblast.at/index.php/File:MiPNet15.03_MultiSensor-ISE.pdf Versions]ย  [[Image:O2k-Manual.jpg|right|150px|link=http://www.oroboros.at/?o2k-manual|O2k-Manual contents]]
|authors=OROBOROS
|authors=OROBOROS
|year=2010
|year=2010
|journal=Mitochondr Physiol Network
|journal=Mitochondr Physiol Network
|abstract=The O2k-MultiSensor extension of the OROBOROS Oxygraph-2k yields a record of a potentiometric (voltage) signal simultaneously to the oxygen signal in both chambers of the O2k. A new ion selective electrode (ISE) system is described here, consisting of separate reference and measuring electrodes. Typical examples are electrodes selective for hydrophobic cations (TPP+, TPMP+), Ca2+, Mg2+, etc. This manual describes the handling and application of this ISE system.
|abstract='''O2k-Manual Chapter H'''
ย 
The O2k-MultiSensor extension of the OROBOROS Oxygraph-2k yields a record of a potentiometric (voltage) signal simultaneously to the oxygen signal in both chambers of the O2k. A new ion selective electrode (ISE) system is described here, consisting of separate reference and measuring electrodes. Typical examples are electrodes selective for hydrophobic cations (TPP+, TPMP+), Ca2+, Mg2+, etc. This manual describes the handling and application of this ISE system.
:>> O2k-Manual: [http://www.oroboros.at/?o2k-manualย  Overall contents]
:>> Product: [http://www.oroboros.at/?oxygraph OROBOROS Oxygraph-2k], [[O2k-Catalogue_OROBOROS| O2k-Catalogue]]
ย 
|keywords=HRR, MultiSensor
|keywords=HRR, MultiSensor
|mipnetlab=AT_Innsbruck_OROBOROS
|mipnetlab=AT_Innsbruck_OROBOROS
|articletype=Protocol; Manual, MiPNet-online Publication
}}
}}
{{Labeling
{{Labeling
|area=Instruments;methods
|area=Instruments;methods
|instruments=Oxygraph-2k, TIP2k, TPP, O2k-Manual, Protocol
|instruments=Oxygraph-2k, TIP2k, TPP, O2k-Manual, Protocol
|additional=O2k-SOP, DatLab
|additional=O2k-SOP, DatLab
|articletype=Protocol; Manual, MiPNet-online Publication
}}
}}
* Version 4: 2012-09-07
* Version 4: 2012-09-07
* Version 1: 2010
* Version 1: 2010

Revision as of 10:44, 17 October 2013

Publications in the MiPMap
Fasching M, Gnaiger E (2010) O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr Physiol Network 15.03.

ยป Open Access-MiPNet15.03.pdf; Versions

O2k-Manual contents

OROBOROS (2010) Mitochondr Physiol Network

Abstract: O2k-Manual Chapter H

The O2k-MultiSensor extension of the OROBOROS Oxygraph-2k yields a record of a potentiometric (voltage) signal simultaneously to the oxygen signal in both chambers of the O2k. A new ion selective electrode (ISE) system is described here, consisting of separate reference and measuring electrodes. Typical examples are electrodes selective for hydrophobic cations (TPP+, TPMP+), Ca2+, Mg2+, etc. This manual describes the handling and application of this ISE system.

>> O2k-Manual: Overall contents
>> Product: OROBOROS Oxygraph-2k, O2k-Catalogue

โ€ข Keywords: HRR, MultiSensor

โ€ข O2k-Network Lab: AT_Innsbruck_OROBOROS


Labels: MiParea: Instruments;methods 





HRR: Oxygraph-2k, TIP2k, TPP, O2k-Manual, Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property. 

O2k-SOP, DatLab 


  • Version 4: 2012-09-07
  • Version 1: 2010