Difference between revisions of "MiPNet15.03 O2k-MultiSensor-ISE"
m (moved H MiPNet15.03 MultiSensor-ISE to MiPNet15.03 MultiSensor-ISE) |
|||
Line 1: | Line 1: | ||
{{Publication | {{Publication | ||
|title=Fasching M, Gnaiger E ( | |title=Fasching M, Gnaiger E (2014) O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr Physiol Network 15.03(05): 1-20. | ||
|info=[[Media:MiPNet15.03_MultiSensor-ISE.pdf|'''Open Access-MiPNet15.03.pdf''']]; [http://www.bioblast.at/index.php/File:MiPNet15.03_MultiSensor-ISE.pdf Versions]ย [[Image:O2k-Manual.jpg|right|150px|link=http://www.oroboros.at/?o2k-manual|O2k-Manual contents]] | |info=[[Media:MiPNet15.03_MultiSensor-ISE.pdf|'''Open Access-MiPNet15.03.pdf''']]; [http://www.bioblast.at/index.php/File:MiPNet15.03_MultiSensor-ISE.pdf Versions]ย [[Image:O2k-Manual.jpg|right|150px|link=http://www.oroboros.at/?o2k-manual|O2k-Manual contents]] | ||
|authors=OROBOROS | |authors=OROBOROS | ||
|year= | |year=2014 | ||
|journal=Mitochondr Physiol Network | |journal=Mitochondr Physiol Network | ||
|abstract='''O2k-Manual Chapter H''' | |abstract='''O2k-Manual Chapter H''' | ||
Line 10: | Line 10: | ||
:>> O2k-Manual: [http://www.oroboros.at/?o2k-manualย Overall contents] | :>> O2k-Manual: [http://www.oroboros.at/?o2k-manualย Overall contents] | ||
:>> Product: [http://www.oroboros.at/?oxygraph OROBOROS Oxygraph-2k], [[O2k-Catalogue_OROBOROS| O2k-Catalogue]] | :>> Product: [http://www.oroboros.at/?oxygraph OROBOROS Oxygraph-2k], [[O2k-Catalogue_OROBOROS| O2k-Catalogue]] | ||
|keywords=HRR, MultiSensor | |keywords=HRR, MultiSensor | ||
|mipnetlab=AT_Innsbruck_OROBOROS | |mipnetlab=AT_Innsbruck_OROBOROS | ||
}} | }} | ||
{{Labeling | {{Labeling | ||
|area=Instruments;methods | |area=Instruments;methods | ||
Line 20: | Line 18: | ||
|additional=O2k-SOP, DatLab | |additional=O2k-SOP, DatLab | ||
}} | }} | ||
Revision as of 21:50, 16 February 2014
Fasching M, Gnaiger E (2014) O2k-MultiSensor system with ion selective electrodes (ISE). Mitochondr Physiol Network 15.03(05): 1-20. |
ยป Open Access-MiPNet15.03.pdf; Versions
OROBOROS (2014) Mitochondr Physiol Network
Abstract: O2k-Manual Chapter H
The O2k-MultiSensor extension of the OROBOROS Oxygraph-2k yields a record of a potentiometric (voltage) signal simultaneously to the oxygen signal in both chambers of the O2k. A new ion selective electrode (ISE) system is described here, consisting of separate reference and measuring electrodes. Typical examples are electrodes selective for hydrophobic cations (TPP+, TPMP+), Ca2+, Mg2+, etc. This manual describes the handling and application of this ISE system.
- >> O2k-Manual: Overall contents
- >> Product: OROBOROS Oxygraph-2k, O2k-Catalogue
โข Keywords: HRR, MultiSensor
โข O2k-Network Lab: AT_Innsbruck_OROBOROS
Labels: MiParea: Instruments;methods
HRR: Oxygraph-2k, TIP2k, TPP, O2k-Manual, Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property.
O2k-SOP, DatLab