MiPNet17.02 PBI-Shredder manual: Difference between revisions
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{Publication | {{Publication | ||
|title=[[Image:O2k-Manual.jpg|right|70px|link=http://wiki.oroboros.at/index.php/O2k-Manual|O2k-Manual]] PBI-Shredder HRR-Set: preparation of tissue homogenates for diagnosis of mitochondrial respiratory function. | |title=[[Image:O2k-Manual.jpg|right|70px|link=http://wiki.oroboros.at/index.php/O2k-Manual|O2k-Manual]] PBI-Shredder HRR-Set: preparation of tissue homogenates for diagnosis of mitochondrial respiratory function. | ||
Line 8: | Line 7: | ||
|abstract=[[Image:PBI-Shredder HRR-Set.JPG|180px|right|link=http://www.bioblast.at/index.php/PBI-Shredder_HRR-Set]] | |abstract=[[Image:PBI-Shredder HRR-Set.JPG|180px|right|link=http://www.bioblast.at/index.php/PBI-Shredder_HRR-Set]] | ||
}} | }} | ||
{{Labeling | |||
|area=Instruments;methods | |||
|preparations=Homogenate | |||
|instruments=O2k-Manual, Protocol | |||
|additional=Auxiliary, Mt-Preparation, PBI-Shredder | |||
}} | |||
{{Mainpage OROBOROS}} | |||
'''Draxl A, Eigentler A, Gnaiger E (2013) PBI-Shredder HRR-Set: preparation of tissue homogenates for diagnosis of mitochondrial respiratory function. Mitochondr Physiol Network 17.02(03): 1-9.''' | '''Draxl A, Eigentler A, Gnaiger E (2013) PBI-Shredder HRR-Set: preparation of tissue homogenates for diagnosis of mitochondrial respiratory function. Mitochondr Physiol Network 17.02(03): 1-9.''' | ||
Line 16: | Line 23: | ||
|mipnetlab=AT_Innsbruck_OROBOROS, AT_Innsbruck_Gnaiger E, AT Innsbruck MitoCom | |mipnetlab=AT_Innsbruck_OROBOROS, AT_Innsbruck_Gnaiger E, AT Innsbruck MitoCom | ||
}} | }} | ||
ย | |||
== Further information == | == Further information == | ||
:>> [[PBI-Shredder HRR-Set]] | :>> [[PBI-Shredder HRR-Set]] |
Revision as of 15:34, 28 July 2014
PBI-Shredder HRR-Set: preparation of tissue homogenates for diagnosis of mitochondrial respiratory function. |
ยป Open Access-MiPNet17.02; Versions
OROBOROS (2013-11) Mitochondr Physiol Network
Abstract:
Labels: MiParea: Instruments;methods
Preparation: Homogenate
HRR: O2k-Manual, Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property.
Auxiliary, Mt-Preparation, PBI-Shredder
Draxl A, Eigentler A, Gnaiger E (2013) PBI-Shredder HRR-Set: preparation of tissue homogenates for diagnosis of mitochondrial respiratory function. Mitochondr Physiol Network 17.02(03): 1-9.
The PBI-Shredder HRR-Set is an auxiliary HRR-Tool providing a standardized approach to prepare homogenates of various tissues with high reproducibility of mitochondrial yield and mitochondrial function. In this manual for applications with high-resolution respirometry (HRR), we refer to the PBI User Manual with safety information, product use limitations and warranty information, and the Product Specification Sheet by Pressure BioSciences Inc. (PBI).
- >> Product: OROBOROS Oxygraph-2k, O2k-Catalogue
|keywords=Tissue homogenate, shredder |mipnetlab=AT_Innsbruck_OROBOROS, AT_Innsbruck_Gnaiger E, AT Innsbruck MitoCom }}