Difference between revisions of "Filter-Cap"
From Bioblast
Line 1: | Line 1: | ||
{{Product | {{Product | ||
|description='''Filter-Cap''': | |description='''Filter-Cap''': O2k-Fluo LED2-Module (O2k-Series D to G) sensors ([[Fluorescence-Sensor Green]] and [[Fluorescence-Sensor Blue]]) and O2k-FluoRespirometer (O2k-Series H) sensors ([[Smart Fluo-Sensor Green]] and [[Smart Fluo-Sensor Blue]]) are equipped with a removable Filter-Cap for exchange of optical filters for the optical pathways from the LED to the sample and from the sample to the photodiode. | ||
|product id=44310-01 | |product id=44310-01 | ||
|product type=O2k, MultiSensor | |product type=O2k, MultiSensor, O2k-FluoRespirometer | ||
|info='''''>> More details? Consult'' [[O2k-Fluorescence LED2-Module]]''' | |info='''''>> More details? Consult'' [[O2k-Fluorescence LED2-Module]]''', '''[[Smart Fluo-Sensor]] | ||
|product image=[[Image:Filter-Cap.JPG|180px|right]] | |product image=[[Image:Filter-Cap.JPG|180px|right]] | ||
}} | }} | ||
Line 15: | Line 15: | ||
=== Mounting a Filter-Cap === | === Mounting a Filter-Cap === | ||
* '''Applies to''': O2k-Fluo LED2-Module (O2k-Series D to G) Fluorescence Sensor; O2k-FluoRespirometer (O2k-Series H) with Smart Fluo-Sensors | |||
* Dismounting: Pull the Filter-Cap straight from the sensor. The Filter-Cap Guide prevents rotational movements. Β | * Dismounting: Pull the Filter-Cap straight from the sensor. The Filter-Cap Guide prevents rotational movements. Β | ||
* Remove all filters and store them in the filter box labeled for this Filter Set. Β | * Remove all filters and store them in the filter box labeled for this Filter Set. Β |
Revision as of 12:27, 25 July 2017
Filter-Cap
Description | Filter-Cap: O2k-Fluo LED2-Module (O2k-Series D to G) sensors (Fluorescence-Sensor Green and Fluorescence-Sensor Blue) and O2k-FluoRespirometer (O2k-Series H) sensors (Smart Fluo-Sensor Green and Smart Fluo-Sensor Blue) are equipped with a removable Filter-Cap for exchange of optical filters for the optical pathways from the LED to the sample and from the sample to the photodiode. |
---|---|
Product ID | 44310-01 |
Type | O2k, MultiSensor, O2k-FluoRespirometer |
Link | >> More details? Consult O2k-Fluorescence LED2-Module, Smart Fluo-Sensor |
Image |
O2k-Guide
Selecting a Filter Set
The Filter-Cap of each sensor can be removed for application of various filter combinations on the same optical sensor.
- Selection of a Filter Set: >> Application specific settings.
Mounting a Filter-Cap
- Applies to: O2k-Fluo LED2-Module (O2k-Series D to G) Fluorescence Sensor; O2k-FluoRespirometer (O2k-Series H) with Smart Fluo-Sensors
- Dismounting: Pull the Filter-Cap straight from the sensor. The Filter-Cap Guide prevents rotational movements.
- Remove all filters and store them in the filter box labeled for this Filter Set.
- Insert the filters form the selected Filter Set: The round filters of each Filter Set fit to the round window of the Filter-Cap and cover the LED, the rectangular filters fit into the rectangular window of the Filter-Cap and cover the photodiode.
- Mounting: Hold sensor and filter cap in a vertical position above you. Align the Filter-Cap with the Filter-Cap Guide (small steel rod) protruding from the sensor. Press the Filter-Cap onto the sensor without rotational movements.
O2k-Guide: Setup - next step Connect Fluorescence-Sensor to O2k