Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "MiPNet19.01D O2k-Calibration"

From Bioblast
Line 1: Line 1:
{{OROBOROS navigation line page name}}
{{Publication
{{Publication
|title=[[Image:O2k-Manual.jpg|right|70px|link=http://wiki.oroboros.at/index.php/O2k-Manual|O2k-Manual]] Oxygen calibration by DatLab.
|title=[[Image:O2k-Manual.jpg|right|70px|link=O2k-Manual|O2k-Manual]] Oxygen calibration by DatLab.
|info=[[Media:MiPNet19.01D O2k-Calibration.pdf|'''Open Access-MiPNet19.01D.pdf''']], [http://www.bioblast.at/index.php/File:MiPNet19.01D_O2k-Calibration.pdf Versions]
|info=[[Media:MiPNet19.01D O2k-Calibration.pdf|Bioblast Access-MiPNet19.01D.pdf]], [http://www.bioblast.at/index.php/File:MiPNet19.01D_O2k-Calibration.pdf Versions]
|authors=OROBOROS
|authors=OROBOROS
|year=2014-03
|year=2014-03
|journal=Mitochondr Physiol Network
|journal=Mitochondr Physiol Network
|abstract='''Gnaiger E (2014) Oxygen calibration by DatLab. Mitochondr Physiol Network 19.01(D01): 41-48.'''
|abstract=Gnaiger E (2014) Oxygen calibration by DatLab. Mitochondr Physiol Network 19.01(D01):41-8.
: ''Updated version:'' '''Β»[[MiPNet19.18D O2k-Calibration]]Β«'''


Β 
|keywords=
[[Accuracy|Accurate]] calibration of the oxygen sensor depends on (1) calibration solutions prepared at known oxygen partial pressures, as achieved in the [[Oxygraph-2k]] (O2k) at defined temperature, continuously recorded total gas pressure (barometric pressure), and thermodynamic equilibrium between the gas and aqueous phase; (2) high stability of the signal of the [[polarographic oxygen sensor]] (POS), tested for sufficiently long periods of time; (3) linearity of signal output with oxygen pressure, achieved with the POS in the range between oxygen saturation and zero oxygen pressure; and (4) application of accurate [[oxygen solubility]] for aqueous solutions for the conversion of partial [[oxygen pressure]] into [[oxygen concentration]] ([[MiPNet06.03]]). The standard oxygen calibration procedure is described for O2k high-resolution respirometry with the automatic calibration routine of DatLab.
Β 
:>> Product: [http://www.oroboros.at/?oxygraph OROBOROS Oxygraph-2k], [[O2k-Catalogue_OROBOROS| O2k-Catalogue]]
|keywords=HRR, DatLab
|mipnetlab=AT_Innsbruck_OROBOROS
|mipnetlab=AT_Innsbruck_OROBOROS
}}
}}
== Related O2k-SOP ==
:: >> [[MiPNet06.03 POS-Calibration-SOP]]
:: >> [[MiPNet14.06 InstrumentalBackground]]


[[Category:OroboPedia]]
[[Category:OroboPedia]]

Revision as of 09:05, 10 May 2015

Publications in the MiPMap
O2k-Manual
Oxygen calibration by DatLab.

Β» Bioblast Access-MiPNet19.01D.pdf, Versions

OROBOROS (2014-03) Mitochondr Physiol Network

Abstract: Gnaiger E (2014) Oxygen calibration by DatLab. Mitochondr Physiol Network 19.01(D01):41-8.

Updated version: Β»MiPNet19.18D O2k-CalibrationΒ«


β€’ O2k-Network Lab: AT_Innsbruck_OROBOROS