Difference between revisions of "O2k-Fluo LED2-Module"
From Bioblast
Line 5: | Line 5: | ||
The MultiSensor electronic upgrade of the O2k-System is required for the simultaneous use of the O2k-Fluorescence Module in two chambers. Β | The MultiSensor electronic upgrade of the O2k-System is required for the simultaneous use of the O2k-Fluorescence Module in two chambers. Β | ||
Basic O2k- | The Basic O2k-System without the MultiSensor upgrade can be used with the [[Preamplifier]] #30430-24, restricting the O2k-Fluorescence Module to one chamber. | ||
|product id=34000-01 | |product id=34000-01 | ||
|product type=MultiSensor, Accessory, DatLab, Stopper, Workshop | |product type=MultiSensor, Accessory, DatLab, Stopper, Workshop | ||
Line 17: | Line 17: | ||
*[[Sumbalova 2011 Abstract Kagoshima|Sumbalova Z, Harrison DK, Gradl P, Fasching M, Gnaiger E (2011) Mitochondrial membrane potential, coupling control, H<sub>2</sub>O<sub>2</sub> production, and the upper limit of mitochondrial performance. Abstract Kagoshima]]. | *[[Sumbalova 2011 Abstract Kagoshima|Sumbalova Z, Harrison DK, Gradl P, Fasching M, Gnaiger E (2011) Mitochondrial membrane potential, coupling control, H<sub>2</sub>O<sub>2</sub> production, and the upper limit of mitochondrial performance. Abstract Kagoshima]]. | ||
==News== | == News == | ||
The first series of the O2k-Fluorescence Module will be completed by beginning of April 2012, and will be delivered in '''April 2012''', for orders received by end of January 2012. | The first series of the O2k-Fluorescence Module will be completed by beginning of April 2012, and will be delivered in '''April 2012''', for orders received by end of January 2012. | ||
==O2k-Fluorimetry Workshop== | Β | ||
== O2k-Fluorimetry Workshop == | |||
*'''[http://www.oroboros.at/index.php?ioc66 O2k-Fluorimetry Workshop from 15 to 16 March 2012]''', Innsbruck, Austria. | *'''[http://www.oroboros.at/index.php?ioc66 O2k-Fluorimetry Workshop from 15 to 16 March 2012]''', Innsbruck, Austria. |
Revision as of 00:20, 18 November 2011
O2k-Fluo LED2-Module
Description | The O2k-Fluorescence Module is a modular extension of the Oxygraph-2k (O2k-MultiSensor System), adding a new dimension to HRR. Optical probes are inserted through the front window of the O2k-glass chamber, for measurement of hydrogen peroxide production (Amplex red), ATP production (Mg green), mt-membrane potential (Safranin), Ca2+ (Ca green), and numerous other applications open for O2k-user innovation. The O2k-Fluorescence Module consists of four optical probes (green or blue excitation), optical filters, front fixation of the optical probes to the glass windows of the O2k-chamber, two black PEEK stoppers (with single central titration port), electronic control of light intensity, data input into the O2k-MultiSensor system, and the new DatLab 5 software.
The Basic O2k-System without the MultiSensor upgrade can be used with the Preamplifier #30430-24, restricting the O2k-Fluorescence Module to one chamber. |
---|---|
Product ID | 34000-01 |
Type | MultiSensor, Accessory"Accessory" is not in the list (O2k, O2k-Module, O2k-Core, O2k-Fluorometer, O2k-Main Unit, O2k-Assembly Kit, OroboPOS, OroboPOS-Service Kit, ISS, TIP2k, ...) of allowed values for the "Product type" property., DatLab"DatLab" is not in the list (O2k, O2k-Module, O2k-Core, O2k-Fluorometer, O2k-Main Unit, O2k-Assembly Kit, OroboPOS, OroboPOS-Service Kit, ISS, TIP2k, ...) of allowed values for the "Product type" property., Stopper, Workshop"Workshop" is not in the list (O2k, O2k-Module, O2k-Core, O2k-Fluorometer, O2k-Main Unit, O2k-Assembly Kit, OroboPOS, OroboPOS-Service Kit, ISS, TIP2k, ...) of allowed values for the "Product type" property. |
Link | http://www.oroboros.at/index.php?o2k-fluorescence |
Image |
References
- Hickey AJ, Renshaw GM, Speers-Roesch B, Richards JG, Wang Y, Farrell AP, Brauner CJ (2011) A radical approach to beating hypoxia: depressed free radical release from heart fibres of the hypoxia-tolerant epaulette shark (Hemiscyllum ocellatum). J. Comp. Physiol. B.[Epub ahead of print].
- Fasching M, Harrison DK, Tretter L, Gnaiger E (2011) Combination of high-resolution respirometry and fluorimetry for continuous monitoring of hydrogen peroxide production by mitochondria with resolution in the nanomolar range. Abstract Berlin.
- Sumbalova Z, Harrison DK, Gradl P, Fasching M, Gnaiger E (2011) Mitochondrial membrane potential, coupling control, H2O2 production, and the upper limit of mitochondrial performance. Abstract Kagoshima.
News
The first series of the O2k-Fluorescence Module will be completed by beginning of April 2012, and will be delivered in April 2012, for orders received by end of January 2012.
O2k-Fluorimetry Workshop
- O2k-Fluorimetry Workshop from 15 to 16 March 2012, Innsbruck, Austria.