(Created page with "High-resolution respirometry is extended by O2k-MultiSensor modules allowing the simultaneous measurement of oxygen consumption and one additional parameter. Fluorometric...")
 
 
Line 8: Line 8:
# Oxygen dependence of parameters can be studied.
# Oxygen dependence of parameters can be studied.
In the publication by [[Krumschnabel_2015_Methods_Mol_Biol|Krumschnabel et al. 2015]] we introduce the O2k-Fluo LED2-Module, describe one selected stage in its development, and show its application for the simultaneous measurement of respiration and H<sub>2</sub>O<sub>2</sub> production of mouse brain mitochondria. The paper by [[Makrecka-Kuka_2015_Biomolecules|Makrecka-Kuka et al. 2015]] focuses on the application of the Amplex red assay for determining H<sub>2</sub>O<sub>2</sub> production in three different models of mitochondrial preparations.
In the publication by [[Krumschnabel_2015_Methods_Mol_Biol|Krumschnabel et al. 2015]] we introduce the O2k-Fluo LED2-Module, describe one selected stage in its development, and show its application for the simultaneous measurement of respiration and H<sub>2</sub>O<sub>2</sub> production of mouse brain mitochondria. The paper by [[Makrecka-Kuka_2015_Biomolecules|Makrecka-Kuka et al. 2015]] focuses on the application of the Amplex red assay for determining H<sub>2</sub>O<sub>2</sub> production in three different models of mitochondrial preparations.
'''O2k-Publication''':
[[Image:O2k-Publications.jpg|50px|link=O2k-Publications:_Topics|O2k-Publications in the MiPMap]]
Krumschnabel G, Fontana-Ayoub M, Sumbalova Z, Heidler J, Gauper K, Fasching M, Gnaiger E (2015) Simultaneous high-resolution measurement of mitochondrial respiration and hydrogen peroxide production. Methods Mol Biol 1264:245-61. [[Krumschnabel 2015 Methods Mol Biol |»Bioblast link«]]
[[Image:O2k-Publications.jpg|50px|left|link=O2k-Publications:_Topics|O2k-Publications in the MiPMap]]
Makrecka-Kuka M, Krumschnabel G, Gnaiger E (2015) High-resolution respirometry for simultaneous measurement of oxygen and hydrogen peroxide fluxes in permeabilized cells, tissue homogenate and isolated mitochondria. Biomolecules 5:1319-38. [[Makrecka-Kuka 2015 Biomolecules| »Bioblast link«]]
|mipnetlab=AT_Innsbruck_Oroboros
}}

Latest revision as of 15:59, 15 November 2019

High-resolution respirometry is extended by O2k-MultiSensor modules allowing the simultaneous measurement of oxygen consumption and one additional parameter. Fluorometric methods are available for a wide range of analytical parameters of major interest in mitochochondrial physiology: H2O2 production, mitochondrial membrane potential, intracellular pH, Ca2+, Mg2+, and NADH levels.

Advantages of the simultaneous measurement of additional parameters in a single respirometric chamber:

  1. Quality control of preparations by respirometric performance.
  2. Objective exclusion criteria for protocol related problems, e.g. overtitration of uncouplers, side effects of TPP+ or fluorophores.
  3. Elimination of artifacts of normalization for a mitochondrial marker when combining two methods in a single chamber.
  4. Additional information is acquired for a limited amount of sample.
  5. Oxygen dependence of parameters can be studied.

In the publication by Krumschnabel et al. 2015 we introduce the O2k-Fluo LED2-Module, describe one selected stage in its development, and show its application for the simultaneous measurement of respiration and H2O2 production of mouse brain mitochondria. The paper by Makrecka-Kuka et al. 2015 focuses on the application of the Amplex red assay for determining H2O2 production in three different models of mitochondrial preparations.