  • ...nsor is not included.|info= [https://www.oroboros.at/index.php/product/o2k-no-amp-module/ '''Product details and purchase information'''] :::: ยป[[MiPNet15.05 NO-manual]]
    6 KB (883 words) - 11:50, 17 August 2022
  • The '''O2k-Fluo Smart-Module''' is an amperometric add-on module to the [[Startup_O2k-Respirometer| O2k-Respirometer]], adding ...ly inserted into the window frame and rotated into final position, leaving no gap between window frame and sensor body.
    6 KB (824 words) - 07:14, 29 March 2024
  • :::::* O2 & Amp: Oxygen and amperometric channel. ::::# The next step is to observe equilibration of the oxygen signal with a defined gas phase above the stirred aqueous phase ('open') chamber;
    11 KB (1,780 words) - 13:28, 21 March 2022
  • ...f O<sub>2</sub> flux is as low as 0.5 pmol.s<sup>-1</sup>.mL<sup>-1</sup>. Signal noise at zero oxygen concentration is <0.05 ฮผM O<sub>2</sub>. Oxygen backd :::::: - Pressure transducer, for absolute barometric pressure signal, resolution 0.1 kPa.
    6 KB (872 words) - 12:49, 31 August 2023
  • ...as the primary signal, which is converted to a voltage (volt [V]) the raw signal. The [[O2k-FluoRespirometer]] supports not only the O<sub>2</sub> channel ( ...the primary signal, which is converted to a voltage (volt [V]) as the raw signal. Therefore, the [[O2k-Fluo LED2-Module]] is connected to the Amp plug (up t
    6 KB (873 words) - 07:12, 29 March 2024
  • == Signal and output == ...to DL8, the primary signal is converted to a voltage (volt [V]) as the raw signal.
    13 KB (1,842 words) - 17:09, 17 January 2024
  • ...ar calibration between oxygen partial pressure and electric current [Amp] (amperometric mode of operation). The [[OroboPOS]] is the POS applied in the [[Oroboros O ...control parameters] are within the recommended range, the [[OroboPOS]] has no limited period of usage.
    6 KB (814 words) - 14:34, 8 August 2023
  • ::::* Re-attach the Sensor-Guide to the O2k-Front-Fixation. (There is no need to use the fixation screw supplied with early models). ...to the side of the Fluorescence-Control Unit to the โ€˜Ampโ€™ plugs (labeled "NO" in Series D-E) on the O2k-Main Unit.
    14 KB (1,881 words) - 10:49, 4 August 2021
  • == Signal and output == ...Amp)-Channel of the O2k, with electric current (ampere [A]) as the primary signal.
    17 KB (2,405 words) - 07:29, 5 April 2024
  • == O2k signal and output == ...nnel of the O2k, with electric potential (volt [V]) as the primary and raw signal
    37 KB (5,713 words) - 12:13, 28 February 2023
  • ::::* EIC-SMEInst-2018-2020 โ€” SME instrument phase 2, Grant Agreement No. 859770, Oroboros Instruments ::::* Amperometric measurement of nitric oxide: the [[O2k-NO Amp-Module]]
    14 KB (1,813 words) - 08:18, 2 April 2024