Description
The netROUTINE control ratio (βR/E control ratio), βR/E = (R-L)/E, expresses phosphorylation-related respiration (corrected for LEAK respiration) as a fraction of ET-capacity. βR/E remains constant, if dyscoupling is fully compensated by an increase of ROUTINE respiration and free ROUTINE activity (βR = R-L) is maintained constant.
Abbreviation: βR/E
Reference: Gnaiger 2014 MitoPathways, Huetter 2004 Biochem J
MitoPedia concepts:
Respiratory control ratio,
Ergodynamics
Compare
- ROUTINE coupling efficiency
- More details: Β»Biochemical coupling efficiency