{{Product
{{Product
|description='''DatLab & Remote Support''': DatLab is the O2k-Software for Data Acquisition & Analysi. The newest DatLab version is included in the O2k-FluoRespirometer and is also available to be purchased as a single package, combined with various services offered the specialists of the Oroboros Instruments.
|description='''Volume calibration ring PVDF M2.5''' (A or B) PVDF for O2k-Stopper sV, white; attached to the [[Stopper sV\black PEEK\conical Shaft\central Port |stoppers]] REPLACE THE LIBK.
|product id=7'''####'''
|product id=2432A-01 or 2432B-01 (PRODUCT ID FOR A AND B?)
|product type=O2k
|product type=O2k, Stopper (TYPE STOPPER?)
|info=[[Oroboros_Events#Next_O2k-Workshops |Next Oroboros O2k-Workshops]]
|info=[[MiPNet22.11 O2k-FluoRespirometer manual]]
|product image=[[Image:O2k-Workshops.png|right|180px]]
|product image=TO REPACE [[Image:Volume calibration ring A+B PVDF for Stopper.jpg|right|180px]]
}}
}}
__TOC__


== DatLab ==
CHECK THE TEXT BELOW


'''[[DatLab]]''' is the O2k-Software for Data Acquisition & Analysis, specifically developed for [[High-Resolution_FluoRespirometry| High-Resolution FluoRespirometry]] with the [[O2k-FluoRespirometer]].
== Technical support ==
The newest DatLab version is included in the [[O2k-FluoRespirometer]], and updates of DatLab are free of charge during the warranty period of the O2k.
::: '''Volume calibration of the [[O2k-sV-Chamber]]'''
::::* Loosen the stopper fixation rings (A) and (B) with the L-shaped Allen key (OroboPOS-Service Kit).
::::* Follow the instructions in the O2k-Manual: [[MiPNet22.11 O2k-FluoRespirometer manual]]
::::* Tighten the screws of the fixation rings (A) and (B) gently with the Allen key to ensure that the calibration ring cannot be displaced. Tightening the screw with too much force may damage the thread of the calibration ring. Check for a sufficient fixation by trying to rotate the calibration ring.


The minimum computer requirements are Intel-Core-2 or equivalent CPU, 2GB RAM and Windows XP. However, we recommend Intel i5 or equivalent CPU, 4GB RAM, Windows 10 and SSD.
[[Image:Volume calibration ring A+B aluminum for Stopper.jpg|right|400px]]
Β 
== Innovation ==
== O2k-Workshops ==
:::: Replacing the (white) PVDF Volume-Calibration Ring with the (black) aluminum Volume-Calibration Ring allows for more force applied to tighten the ring, thus reducing the risk of a loose fit and the associated danger of altering the calibrated position.
Β 
'''[[Oroboros O2k-Workshops]]''' are organized as international oxygraph courses (IOC) on [[High-Resolution FluoRespirometry]] since 1991. These range from four full-day training courses to conference lunch presentations of the [[Oroboros O2k]] and particularly the [[O2k-FluoRespirometer]]'''.
Β 
== O2k Startup Service ==
Β 
'''[[O2k start-up service]]''', O2k training course (1 - 3 days). In most cases, the O2k-Manual provides sufficient detail for setting up the O2k and starting measurements, particularly in conjunction with participation in an introductory [[O2k-Workshop\4 Days\Standard|O2k-Workshop]]. For specific requirements, however, a start-up visit by a scientific application specialist supports a highly efficient start of a project.
|product id=72003-01
Β 
== MitoFit Proficiency Test ==
Β 
The '''[[MitoFit Proficiency Test]] for High-Resolution FluoRespirometry''' includes the user-friendly software [[DatLab |DatLab 7.3]] and the Oroboros Premium Customer Support. Upon successful completion of the test, a MitoFit Proficiency Certificate will be conferred from Oroboros Instruments acknowledging your personal proficiency in your laboratory environment. The standard package includes the MiR05-Kit and cryopreserved HEK 293T cells for the Proficiency Test '''for up to three participants from the same research group.'''

Latest revision as of 11:19, 6 November 2019

                



User talk:Zhang Feiyuan/My sandbox 7

O2k-Catalogue

Description Volume calibration ring PVDF M2.5 (A or B) PVDF for O2k-Stopper sV, white; attached to the stoppers REPLACE THE LIBK.
Product ID 2432A-01 or 2432B-01 (PRODUCT ID FOR A AND B?)
Type O2k, Stopper (TYPE STOPPER?)
Link MiPNet22.11 O2k-FluoRespirometer manual
Image TO REPACE
Volume calibration ring A+B PVDF for Stopper.jpg


CHECK THE TEXT BELOW

Technical support

Volume calibration of the O2k-sV-Chamber
  • Loosen the stopper fixation rings (A) and (B) with the L-shaped Allen key (OroboPOS-Service Kit).
  • Follow the instructions in the O2k-Manual: MiPNet22.11 O2k-FluoRespirometer manual
  • Tighten the screws of the fixation rings (A) and (B) gently with the Allen key to ensure that the calibration ring cannot be displaced. Tightening the screw with too much force may damage the thread of the calibration ring. Check for a sufficient fixation by trying to rotate the calibration ring.
Volume calibration ring A+B aluminum for Stopper.jpg

Innovation

Replacing the (white) PVDF Volume-Calibration Ring with the (black) aluminum Volume-Calibration Ring allows for more force applied to tighten the ring, thus reducing the risk of a loose fit and the associated danger of altering the calibrated position.