|description=The '''O2k-Fluorescence LED2-Module''' is an amperometric add-on module to the [[O2k-Core]], adding a new dimension to [[HRR]]. Optical probes are inserted through the front window of the O2k-glass chambers, for measurement of '''hydrogen peroxide production''' ([[Amplex red]]), '''ATP production''' ([[Mg green]]), '''mt-membrane potential''' ([[Safranin]]), '''Ca<sup>2+</sup>''' ([[Ca green]]), and numerous other applications open for O2k-user innovation. Β 
|description=The '''O2k-Fluorescence LED2-Module''' is an amperometric add-on module to the [[O2k-Core]], adding a new dimension to [[HRR]]. Optical probes are inserted through the front window of the O2k-glass chambers, for measurement of '''hydrogen peroxide production''' ([[Amplex red]]), '''ATP production''' ([[Mg green]]), '''mt-membrane potential''' ([[Safranin]]), '''Ca<sup>2+</sup>''' ([[Ca green]]), and numerous other applications open for O2k-user innovation. Β 
The O2k-Fluorescence LED2-Module consists of optical probes for both [[O2k-Chamber]]s (LEDs for green and blue excitation), optical filters, [[Fluorescence-Control Unit]] for regulation of light intensity, data input into the [[O2k-Main Unit]], and the updated '''DatLab''' software.
The O2k-Fluorescence LED2-Module consists of optical probes for both [[O2k-Chamber]]s (LEDs for green and blue excitation), optical filters, [[Fluorescence-Control Unit]] for regulation of light intensity, data input into the [[O2k-Main Unit]], and the updated '''DatLab''' software.
|product id=12100-01
|product id=12100-01
|product type=O2k, O2k-Module, MultiSensor, Catalogue
|product type=O2k, O2k-Module, MultiSensor, Catalogue
|info=[http://www.oroboros.at/?O2k-Fluorescence O2k-Fluorescence@OROBOROS], [[Oxygraph-2k]]
|info=[http://www.oroboros.at/?O2k-Fluorescence O2k-Fluorescence@OROBOROS], [[Oxygraph-2k]]
|product image=[[File:O2k-Fluorescence LED2-Module Prototype 2844.JPG|200px|right|link=]]
}}
}}
{{OroboroPedia}}
{{MitoPedia methods
{{MitoPedia methods
|mitopedia method=Fluorometry
|mitopedia method=Fluorometry

Revision as of 09:53, 9 March 2012

                



O2k-Fluo LED2-Module

O2k-Catalogue

Description The O2k-Fluorescence LED2-Module is an amperometric add-on module to the O2k-Core, adding a new dimension to HRR. Optical probes are inserted through the front window of the O2k-glass chambers, for measurement of hydrogen peroxide production (Amplex red), ATP production (Mg green), mt-membrane potential (Safranin), Ca2+ (Ca green), and numerous other applications open for O2k-user innovation.

The O2k-Fluorescence LED2-Module consists of optical probes for both O2k-Chambers (LEDs for green and blue excitation), optical filters, Fluorescence-Control Unit for regulation of light intensity, data input into the O2k-Main Unit, and the updated DatLab software.

Product ID 12100-01
Type O2k, O2k-Module, MultiSensor, Catalogue
Link O2k-Fluorescence@OROBOROS, Oxygraph-2k
Image

Template:OroboroPedia


MitoPedia methods: Fluorometry 



The O2k-Fluorescence LED2-Module consists of

The query description has an empty condition.

References


News

The first series of the O2k-Fluorescence LED2-Module will be completed by April 2012, and can be delivered in April/May 2012.