|description=[[Image:SmartFluo.png|200px|right]]'''Smart Fluo-Sensor Green''': Excitation LED 525 nm (dominant wavelength) with short pass filter, emission (red) with long pass filter, individual sensors are calibrated with sensor-specific memory and direct input into DatLab 7 to obtain reproducible light intensities with different sensors, including photodiode, [[Filter-Cap]] equipped with [[Filter Set AmR]] for [[Amplex® UltraRed|Amplex UltraRed]] and [[TMRM]] measurements when delivered. | |description=[[Image:SmartFluo.png|200px|right]]'''Smart Fluo-Sensor Green''': Excitation LED 525 nm (dominant wavelength) with short pass filter, emission (red) with long pass filter, individual sensors are calibrated with sensor-specific memory and direct input into DatLab 7 to obtain reproducible light intensities with different sensors, including photodiode, [[Filter-Cap]] equipped with [[Filter Set AmR]] for [[Amplex® UltraRed|Amplex UltraRed]] and [[TMRM]] measurements when delivered. | ||
|info=[ | |info=[https://www.oroboros.at/index.php/product/smart-fluo-sensor-green/ '''Product details and purchase information'''] | ||
}} | }} | ||
== Additional resources == | |||
:::*[[O2k-Fluo Smart-Module]] | |||
{{MitoPedia O2k and high-resolution respirometry | {{MitoPedia O2k and high-resolution respirometry | ||
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry | |mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry | ||
}} | }} |
Revision as of 10:13, 11 November 2020
Smart Fluo-Sensor Green |
MitoPedia O2k and high-resolution respirometry:
O2k-Open Support
Description
Smart Fluo-Sensor Green: Excitation LED 525 nm (dominant wavelength) with short pass filter, emission (red) with long pass filter, individual sensors are calibrated with sensor-specific memory and direct input into DatLab 7 to obtain reproducible light intensities with different sensors, including photodiode, Filter-Cap equipped with Filter Set AmR for Amplex UltraRed and TMRM measurements when delivered.
Reference: Product details and purchase information
Additional resources