Difference between revisions of "Stirrer-Bar\white PVDF\15x6 mm"

From Bioblast
m (Reverted edits by Beno Marija (talk) to last revision by Schmarl Johannes)
Line 1: Line 1:
{{Product
{{Technical support}}
|description='''Stirrer-Bar\white [[PVDF]]\15x6 mm''', operated in the [[O2k-Chamber]] at constant stirring speed (standard is 750 rpm, or 12.5 Hz), to provide optimum mixing of the sample in the aqueous medium and ensure a stable signal of the polarographic oxygen sensor ([[OroboPOS]]) placed in a position of maximum current of the medium.
__TOC__
{{MitoPedia without banner
|abbr=
|description=[[Image:Stirrer bar PVDF.jpg|right|180px]]'''Stirrer-Bar\white [[PVDF]]\15x6 mm''', operated in the [[O2k-Chamber]] at constant stirring speed (standard is 750 rpm, or 12.5 Hz), to provide optimum mixing of the sample in the aqueous medium and ensure a stable signal of the polarographic oxygen sensor ([[OroboPOS]]) placed in a position of maximum current of the medium.




Line 6: Line 9:


[[O2k-FluoRespirometer]]: 2 in [[O2k-Assembly Kit]].
[[O2k-FluoRespirometer]]: 2 in [[O2k-Assembly Kit]].
|product id=23210-01
* For dispatch of the [[O2k-FluoRespirometer]], the Stirrer-Bars are shipped in the [[O2k-Service Box]].
|product type=O2k, O2k-Assembly Kit
|info=[[MiPNet06.01 O2k-Overview]]
|info=[[MiPNet06.01 O2k-Overview]]
|product image=[[Image:Stirrer bar PVDF.jpg|right|180px]]
}}
}}
* For dispatch of the [[O2k-FluoRespirometer]], the Stirrer-Bars are shipped in the [[O2k-Service Box]].


A "jumping" stirring bar problem is frequently caused by small particles sticking to the glass chamber, not the stirring bar itself. >> [[MiPNet19.03 O2k-cleaning and ISS]].
Β 
== Additional resources ==
Β» A "jumping" stirring bar problem is frequently caused by small particles sticking to the glass chamber, not the stirring bar itself. >> [[MiPNet19.03 O2k-cleaning and ISS]].
Β 
Β 
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry
}}

Revision as of 16:36, 13 October 2020


                  


O2k-Open Support

Stirrer-Bar\white PVDF\15x6 mm



Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Description

Stirrer bar PVDF.jpg

Stirrer-Bar\white PVDF\15x6 mm, operated in the O2k-Chamber at constant stirring speed (standard is 750 rpm, or 12.5 Hz), to provide optimum mixing of the sample in the aqueous medium and ensure a stable signal of the polarographic oxygen sensor (OroboPOS) placed in a position of maximum current of the medium.


Two units of this item are standard components of the O2k-Assembly Kit (O2k-FluoRespirometer).

O2k-FluoRespirometer: 2 in O2k-Assembly Kit.


Reference: MiPNet06.01 O2k-Overview


Additional resources

Β» A "jumping" stirring bar problem is frequently caused by small particles sticking to the glass chamber, not the stirring bar itself. >> MiPNet19.03 O2k-cleaning and ISS.