Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "O2k-Fluo LED2-Module"

From Bioblast
Line 4: Line 4:
The O2k-Fluorescence LED2-Module consists of optical sensors for both [[O2k-Chamber]]s (LEDs for green and blue excitation), optical filters, [[Fluorescence-Control Unit]] for regulation of light intensity, data input into the [[O2k-Main Unit]], and the updated '''DatLab''' software.
The O2k-Fluorescence LED2-Module consists of optical sensors for both [[O2k-Chamber]]s (LEDs for green and blue excitation), optical filters, [[Fluorescence-Control Unit]] for regulation of light intensity, data input into the [[O2k-Main Unit]], and the updated '''DatLab''' software.
|product id=12100-01
|product id=12100-01
|product type=O2k, O2k-Module, MultiSensor, Catalogue
|product type=O2k, O2k-Module, MultiSensor, Catalogue, O2k-Manual
|info=[http://www.oroboros.at/?O2k-Fluorescence O2k-Fluorescence@OROBOROS], [[Oxygraph-2k]]
|info=[http://www.oroboros.at/?O2k-Fluorescence O2k-Fluorescence@OROBOROS], [[Oxygraph-2k]]
|product image=[[File:O2k-Fluorescence LED2-Module Prototype 2844.JPG|180px|right|link=]]
|product image=[[File:O2k-Fluorescence LED2-Module Prototype 2844.JPG|180px|right|link=]]
Line 17: Line 17:
|order=ascending
|order=ascending
}}
}}
== News ==
=== Delivery ===
The first series of the O2k-Fluorescence LED2-Module will be completed by April 2012, and can be delivered in '''April/May 2012'''.
=== O2k-Fluorometry Workshop: March 2012 ===
*'''[http://www.oroboros.at/index.php?IOC66 O2k-Fluorometry Workshop from 15 to 16 March 2012]''', Innsbruck, Austria.
== O2k-Manual: O2k-Fluorescence LED2-Module ==
As an innovation in our 'open innovation' approach, the '''Manual for the O2k-Fluorescence LED2-Module''' evolves as a guided tour through the '''O2k-Catalogue: O2k-Fluorescence LED2-Module'''.
=== Setup of the O2k-Fluorescence LED2-Module ===
# [[Fluorescence-Control_Unit#Setup_of_the_O2k-Fluorescence_LED2-Module|Setup of the O2k-Fluorescence LED2-Module]]
# [[Filter-Cap#Mounting_a_Filter-Cap|Mounting a Filter-Cap]]
# [[Fluorescence-Sensor_Green#Connect_Fluorescence-Sensor_to_O2k|Connect Fluorescence-Sensor to O2k]]


== References ==
== References ==
Line 24: Line 40:
*[[Fasching 2011 Abstract Berlin|Fasching M, Harrison DK, Tretter L, Gnaiger E (2011) Combination of high-resolution respirometry and fluorometry for continuous monitoring of hydrogen peroxide production by mitochondria with resolution in the nanomolar range. Abstract Berlin]]. Β 
*[[Fasching 2011 Abstract Berlin|Fasching M, Harrison DK, Tretter L, Gnaiger E (2011) Combination of high-resolution respirometry and fluorometry for continuous monitoring of hydrogen peroxide production by mitochondria with resolution in the nanomolar range. Abstract Berlin]]. Β 
*[[Sumbalova 2011 Abstract Kagoshima|Sumbalova Z, Harrison DK, Gradl P, Fasching M, Gnaiger E (2011) Mitochondrial membrane potential, coupling control, H<sub>2</sub>O<sub>2</sub> production, and the upper limit of mitochondrial performance. Abstract Kagoshima]].
*[[Sumbalova 2011 Abstract Kagoshima|Sumbalova Z, Harrison DK, Gradl P, Fasching M, Gnaiger E (2011) Mitochondrial membrane potential, coupling control, H<sub>2</sub>O<sub>2</sub> production, and the upper limit of mitochondrial performance. Abstract Kagoshima]].
== News ==
The first series of the O2k-Fluorescence LED2-Module will be completed by April 2012, and can be delivered in '''April/May 2012'''.
== O2k-Fluorometry Workshop ==
*'''[http://www.oroboros.at/index.php?IOC66 O2k-Fluorometry Workshop from 15 to 16 March 2012]''', Innsbruck, Austria.


See also Β 
See also Β 

Revision as of 19:48, 11 March 2012

Template:OroboroPedia

                



O2k-Fluo LED2-Module

O2k-Catalogue

Description The O2k-Fluorescence LED2-Module is an amperometric add-on module to the O2k-Core, adding a new dimension to HRR. Optical sensors are inserted through the front window of the O2k-glass chambers, for measurement of hydrogen peroxide production (Amplex red), ATP production (Mg green), mt-membrane potential (Safranin), Ca2+ (Ca green), and numerous other applications open for O2k-user innovation.

The O2k-Fluorescence LED2-Module consists of optical sensors for both O2k-Chambers (LEDs for green and blue excitation), optical filters, Fluorescence-Control Unit for regulation of light intensity, data input into the O2k-Main Unit, and the updated DatLab software.

Product ID 12100-01
Type O2k, O2k-Module, MultiSensor, Catalogue, O2k-Manual"O2k-Manual" is not in the list (O2k, O2k-Module, O2k-Core, O2k-Fluorometer, O2k-Main Unit, O2k-Assembly Kit, OroboPOS, OroboPOS-Service Kit, ISS, TIP2k, ...) of allowed values for the "Product type" property.
Link O2k-Fluorescence@OROBOROS, Oxygraph-2k
Image

The O2k-Fluorescence LED2-Module consists of

The query description has an empty condition.

News

Delivery

The first series of the O2k-Fluorescence LED2-Module will be completed by April 2012, and can be delivered in April/May 2012.

O2k-Fluorometry Workshop: March 2012


O2k-Manual: O2k-Fluorescence LED2-Module

As an innovation in our 'open innovation' approach, the Manual for the O2k-Fluorescence LED2-Module evolves as a guided tour through the O2k-Catalogue: O2k-Fluorescence LED2-Module.

Setup of the O2k-Fluorescence LED2-Module

  1. Setup of the O2k-Fluorescence LED2-Module
  2. Mounting a Filter-Cap
  3. Connect Fluorescence-Sensor to O2k


References

See also


MitoPedia methods: Fluorometry