== O2k-Guide: O2k-Fluorescence LED2-Module ==
== O2k-Manual: O2k-Fluorescence LED2-Module ==
As an innovation in our 'open innovation' approach, the '''''Manual'' for the O2k-Fluorescence LED2-Module''' evolves as a guided tour through the '''O2k-Catalogue: O2k-Fluorescence LED2-Module'''.
As an innovation in our 'open innovation' approach, the '''''Manual'' for the O2k-Fluorescence LED2-Module''' evolves as a guided tour through the '''O2k-Catalogue: O2k-Fluorescence LED2-Module'''.



Revision as of 13:23, 5 May 2012

Template:OroboroPedia

                



O2k-Fluo LED2-Module

O2k-Catalogue

Description The O2k-Fluorescence LED2-Module is an amperometric add-on module to the O2k-Core, adding a new dimension to HRR. Optical sensors are inserted through the front window of the O2k-glass chambers, for measurement of hydrogen peroxide production (Amplex red), ATP production (Magnesium green), mt-membrane potential (Safranin), Ca2+ (Calcium green), and numerous other applications open for O2k-user innovation.

The O2k-Fluorescence LED2-Module consists of optical sensors for both O2k-Chambers (LEDs for green and blue excitation), optical filters, Fluorescence-Control Unit for regulation of light intensity, data input into the O2k-Main Unit, and the updated DatLab software.

Product ID 12100-01
Type O2k, O2k-Module, MultiSensor, Catalogue
Link O2k-Fluorescence@OROBOROS, Oxygraph-2k
Image
O2k-Fluorometer Series G.jpg

The O2k-Fluorescence LED2-Module consists of

The query description has an empty condition.

News

Delivery

The first series of the O2k-Fluorescence LED2-Module will be completed by April 2012, and can be delivered in April/May 2012.

O2k-Fluorometry Workshop: March 2012


O2k-Manual: O2k-Fluorescence LED2-Module

As an innovation in our 'open innovation' approach, the Manual for the O2k-Fluorescence LED2-Module evolves as a guided tour through the O2k-Catalogue: O2k-Fluorescence LED2-Module.

Setup of the O2k-Fluorescence LED2-Module

  1. Setup of the O2k-Fluorescence LED2-Module
  2. Mounting a Filter-Cap
  3. Connect Fluorescence-Sensor to O2k

Electronic settings

  1. Power on
  2. Control of LED-intensity
  3. Amplification

Application specific settings

Application Sensor Filter set Light intensity (LED current) Light intensity (switch position)
Amplex® UltraRed Fluorescence-Sensor Green AmR 2 mA 4
Safranin Fluorescence-Sensor Blue Saf 1 mA 3
Magnesium green Fluorescence-Sensor Blue MgG / CaG 1 mA 3
Calcium green Fluorescence-Sensor Blue MgG / CaG

Calibration

DatLab-Analysis

References

See also


Template:Technical service

MitoPedia methods: Fluorometry