Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Template:Current week ecosystem agenda"

From Bioblast
Line 1: Line 1:
{{Template:Science for Ukraine}}
{{Template:Science for Ukraine}}
2024 Week 14
* '''Apr-01 Mo'''  April - Parkinson's Disease Awareness Month
:{|
| width="100" align="center" |[[Image:O2k-Publications.jpg|70px|link=http://wiki.oroboros.at/index.php/O2k-Publications:_Topics |O2k-Publications in the MiPMap]]
|'''"Although the chain of events leading to this respiration deficit is currently not understood, the findings constitute a robust assay for the progressive pathology induced by PINK1 deficiency."''' <br>
* Gispert S, Ricciardi F, Kurz A, Azizov M, Hoepken HH, Becker D, Voos W, Leuner K, Müller WE, Kudin AP, Kunz WS, Zimmermann A, Roeper J, Wenzel D, Jendrach M, García-Arencíbia M, Fernández-Ruiz J, Huber L, Rohrer H, Barrera M, Reichert AS, Rüb U, Chen A, Nussbaum RL, Auburger G (2009) Parkinson phenotype in aged PINK1-deficient mice is accompanied by progressive mitochondrial dysfunction in absence of neurodegeneration. [[Gispert 2009 PLoS One|»Bioblast link«]]
:from the O2k-Network »[[US CA San Francisco Nussbaum RL]]« and »[[DE Frankfurt Eckert GP]]«
|} 
----
* '''Apr-02 Tu'''
----
* '''Apr-03 We'''
----
* '''Apr-04 Th'''
:{|
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
|''' Why is it important to check the H<sub>2</sub>O<sub>2</sub> sensitivity when conducting an Amplex UltraRed (AmR) assay?
The sensitivity is influenced by experimental time, medium composition, added chemicals and sample, requiring multiple H<sub>2</sub>O<sub>2</sub> calibrations throughout the measurement. After the initial AmR calibration, ensure that the sensitivity is within the recommended range.'''<br>
- »'''[[MiPNet24.10 H2O2 flux analysis]]'''«, »'''[https://wiki.oroboros.at/index.php/Amplex_UltraRed#Calibration_with_H2O2 Amplex UltraRed]'''«  <br>
- communicated by »[[Grings Mateus]]« and »[[Schmitt Sabine]]«
|}
----
* '''Apr-05 Fr'''
----
'''<big>Next Week</big>'''
  2024 Week 15
  2024 Week 15


Line 57: Line 27:
----
----
* '''Apr-12 Fr'''
* '''Apr-12 Fr'''
----
'''<big>Next Week</big>'''
2024 Week 16
* '''Apr-15 Mo'''
:{|
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
|'''Do you observe either a zero or low raw O<sub>2</sub> signal when starting a measurement?'''<br>
Perform a test to evaluate whether this is related to an improperly positioned chamber or a faulty connection between the OroboPOS and the OroboPOS-Connector. <br>
- »'''[https://wiki.oroboros.at/index.php/Oxygen_signal#Raw_signal Oxygen signal]'''«<br>
- communicated by »[[Grings Mateus]]« and »[[Schmitt Sabine]]«
|}
----
* '''Apr-16 Tu'''
----
* '''Apr-17 We'''
----
* '''Apr-18 Th'''
:{|
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
|''' How to store the POS overnight and up to several months? '''<br>
Fill the chamber and the receptacle of the loosely inserted stopper with 70 % EtOH, add the Cover-slip and switch off the O2K. <br>
- »'''[[MiPNet19.03 O2k-cleaning and ISS]]'''«<br>
- communicated by »[[Leo Elettra]]« and »[[Grings Mateus]]«
|}
----
* '''Apr-19 Fr'''
----

Revision as of 08:47, 8 April 2024

Gentle Science
Oroboros declares solidarity against the Russian aggression-war in Ukraine and against all aggression-wars worldwide. -  »More details
A future for Ukraine is the future of its science
2024 Week 15
  • Apr-08 Mo
16:30 Erich Gnaiger presenting a MOSBRI Consensus Meeting satellite seminar at O2k-Network Lab IT Rome Giuffre A - Unlocking cell metabolism: Exploring the power of high-resolution respirometry with the NextGen-O2k

  • Apr-09 Tu
10:00 Erich Gnaiger presenting at MOSBRI Consensus Meeting 2024 Rome IT - Quality-controlled high-resolution respirometry: bacterial and clinical applications

  • Apr-10 We
MitoPedia
Is fatty acid oxidation (FAO) considered as CI- or CII-driven respiration?

Neither. There is simultaneous electron transfer from FAO into the Q-junction through the electron transferring flavoprotein dehydrogenase complex (CETFDH) and Complex I.
- »Fatty acid oxidation«, »Gnaiger 2020 BEC MitoPathways«, »Gnaiger 2024 J Biol Chem« 
- communicated by »Timon-Gomez Alba« and »Willis Jaime R« 


  • Apr-11 Th

World Parkinson's Disease Day

O2k-Publications in the MiPMap "The markers of mitochondrial biogenesis were consistently affected in PD [Parkinson’s disease] patients group."
  • Kamienieva I, Charzyńska A, Duszyński J, Malińska D, Szczepanowska J (2023) In search for mitochondrial biomarkers of Parkinson's disease: Findings in parkin-mutant human fibroblasts. »Bioblast link«
from the O2k-Network »PL Warsaw Szewczyk A«

  • Apr-12 Fr

Next Week

2024 Week 16
  • Apr-15 Mo
O2k-Open SupportInfo: improve Do you observe either a zero or low raw O2 signal when starting a measurement?

Perform a test to evaluate whether this is related to an improperly positioned chamber or a faulty connection between the OroboPOS and the OroboPOS-Connector.
- »Oxygen signal«
- communicated by »Grings Mateus« and »Schmitt Sabine«


  • Apr-16 Tu

  • Apr-17 We

  • Apr-18 Th
O2k-Open SupportInfo: improve How to store the POS overnight and up to several months?

Fill the chamber and the receptacle of the loosely inserted stopper with 70 % EtOH, add the Cover-slip and switch off the O2K.
- »MiPNet19.03 O2k-cleaning and ISS«
- communicated by »Leo Elettra« and »Grings Mateus«


  • Apr-19 Fr