Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "O2k-Catalogue: O2k-Modules"

From Bioblast
 
(59 intermediate revisions by 9 users not shown)
Line 1: Line 1:
{{OroboroPedia}}
{{Product
 
|description='''4'''#### '''''O2k-Catalogue: O2k-Modules'''''. O2k-Modules can be obtained with the O2k or added later, and can be simply installed by the user.
== '''List of O2k-MultiSensor products''' ==
|product id=4'''####'''
|product type=O2k, MultiSensor,
|product image='''4'''####
}}


Please visit the [http://www.oroboros.at/index.php?id=mipnetanalyzer MultiSensor page] for an overview of MultiSensor options for the O2k.
[[File:O2k-Core to FluoRespirometer.jpg|right|400px |O2k-Core to FluoRespirometer]]
== O2k-Modules ==


'''Back to: [[List of all products]]'''
'''O2k-Modules''' are add-on modules supported by the O2k. When one (or more) analytical parameters are monitored simultaneously with oxygen concentration and oxygen flux in the O2k, this is an '''O2k-MultiSensor''' application.  The O2k fully supports the O2k-Modules.
* [[MiPNet17.05 O2k-Fluo LED2-Module]]
* [[O2k-TPP%2B_ISE-Module]]
* [[O2k-pH ISE-Module]]
* [[O2k-NO Amp-Module]]
* [[Hydrogen peroxide]]
* [[Cytochrome Spectra and Oxygen]]
[[High-resolution respirometry]] is extended by O2k-MultiSensor modules allowing the simultaneous measurement of oxygen consumption and one additional parameter. Fluorometric methods are available for a wide range of analytical parameters of major interest in mitochochondrial physiology: [[O2k-Publications:_O2k-Fluorometry_-_Fluorophores|H<sub>2</sub>O<sub>2</sub> production, mitochondrial membrane potential, intracellular pH, Ca<sup>2+</sup>, Mg<sup>2+</sup>, and NADH levels]].


Submit your order: [[Has mailaddress::{{{mailaddress|instruments@oroboros.at}}}]]
Advantages of the simultaneous measurement of additional parameters in a single respirometric chamber:
# Quality control of preparations by respirometric performance.
# Objective exclusion criteria for protocol related problems, e.g. overtitration of uncouplers, side effects of TPP<sup>+</sup> or fluorophores.
# Elimination of artifacts of normalization for a mitochondrial marker when combining two methods in a single chamber.
# Additional information is acquired for a limited amount of sample.
# Oxygen dependence of parameters can be studied.




{{#ask: mainlabel=Title|[[Category:Products]] | [[Product type::MultiSensor]]  
== '''O2k-Catalogue: O2k-Modules''' ==
{{#ask:[[Category:Products]][[Product type::O2k-Module]]  
| ?description
| ?description
| ?product id
| ?product id
| ?product image
| ?product image
|sort=product id
|order=ascending
}}
== O2k-MultiSensor Manual ==
{{#ask:[[Category:Publications]] [[Instrument and method::O2k-Manual]] [[Additional label::O2k-MultiSensor]]
| mainlabel=Chapter
|?Has title=Section
|?Was published in year=Last update
|format=broadtable
|limit=500
|sort=
|order=ascending
|offset=0
}}
}}
: »[[O2k-Publications: O2k-Fluorometry]]
== References ==
:::* Makrecka-Kuka M, Krumschnabel G, Gnaiger E (2015) High-resolution respirometry for simultaneous measurement of oxygen and hydrogen peroxide fluxes in permeabilized cells, tissue homogenate and isolated mitochondria. Biomolecules 5:1319-38. - [[Makrecka-Kuka 2015 Biomolecules |»Bioblast link«]]
:::* Krumschnabel G, Fontana-Ayoub M, Sumbalova Z, Heidler J, Gauper K, Fasching M, Gnaiger E (2015) Simultaneous high-resolution measurement of mitochondrial respiration and hydrogen peroxide production. Methods Mol Biol 1264:245-61. - [[Krumschnabel 2015 Methods Mol Biol |»Bioblast link«]]

Latest revision as of 17:10, 15 November 2019

                



O2k-Catalogue: O2k-Modules

O2k-Catalogue

Description 4#### O2k-Catalogue: O2k-Modules. O2k-Modules can be obtained with the O2k or added later, and can be simply installed by the user.
Product ID 4####
Type O2k, MultiSensor
Link
Image 4####


O2k-Core to FluoRespirometer

O2k-Modules

O2k-Modules are add-on modules supported by the O2k. When one (or more) analytical parameters are monitored simultaneously with oxygen concentration and oxygen flux in the O2k, this is an O2k-MultiSensor application. The O2k fully supports the O2k-Modules.

High-resolution respirometry is extended by O2k-MultiSensor modules allowing the simultaneous measurement of oxygen consumption and one additional parameter. Fluorometric methods are available for a wide range of analytical parameters of major interest in mitochochondrial physiology: H2O2 production, mitochondrial membrane potential, intracellular pH, Ca2+, Mg2+, and NADH levels.

Advantages of the simultaneous measurement of additional parameters in a single respirometric chamber:

  1. Quality control of preparations by respirometric performance.
  2. Objective exclusion criteria for protocol related problems, e.g. overtitration of uncouplers, side effects of TPP+ or fluorophores.
  3. Elimination of artifacts of normalization for a mitochondrial marker when combining two methods in a single chamber.
  4. Additional information is acquired for a limited amount of sample.
  5. Oxygen dependence of parameters can be studied.


O2k-Catalogue: O2k-Modules

O2k-MultiSensor Manual

ChapterSectionLast update
MiPNet15.03 O2k-MultiSensor-ISE
O2k-Manual
O2k-MultiSensor system with ion selective electrodes (ISE).
2021-08-02
MiPNet15.05 NO-manual
O2k-Manual
O2k-MultiSensor system with amperometric sensors: NO, H2S, H2O2.
2016-04-21
MiPNet17.05 O2k-Fluo LED2-Module
O2k-Manual
O2k-Fluo LED2-Module.
2021-06-22
MiPNet23.15 O2k-pH ISE-Module
O2k-Manual
Measurement of proton flux with the O2k-pH ISE-Module.
2018-09-08
MiPNet24.12 NextGen-O2k: Q-Module
O2k-Manual
NextGen-O2k: Q-Module manual
2021-10-29
MiPNet26.11 NextGen-O2k: PB-Module
O2k-Manual
NextGen-O2k: PB-Module manual
2021-10-29
MiPNet26.12 NextGen-O2k: NADH-Module
O2k-Manual
NextGen-O2k: NADH-Module manual
2022-05-17
MiPNet28.09 O2k-Fluo Smart-Module manual
O2k-Manual
O2k-Fluo Smart-Module manual
2023-09-25
»O2k-Publications: O2k-Fluorometry

References

  • Makrecka-Kuka M, Krumschnabel G, Gnaiger E (2015) High-resolution respirometry for simultaneous measurement of oxygen and hydrogen peroxide fluxes in permeabilized cells, tissue homogenate and isolated mitochondria. Biomolecules 5:1319-38. - »Bioblast link«
  • Krumschnabel G, Fontana-Ayoub M, Sumbalova Z, Heidler J, Gauper K, Fasching M, Gnaiger E (2015) Simultaneous high-resolution measurement of mitochondrial respiration and hydrogen peroxide production. Methods Mol Biol 1264:245-61. - »Bioblast link«