|description=A system is in a '''steady state''' if the levels of a specific variable (''e.g.'' O<sub>2</sub> flux, H<sub>2</sub>O<sub>2</sub> flux, mitochondrial membrane potential) in the system do not change over time. [[High-resolution respirometry| High-resolution respirometry]] allows for the measurement of different parameters (e.g. O<sub>2</sub> flux, H<sub>2</sub>O<sub>2</sub> flux, mitochondrial membrane potential) at a pseudo-steady state, when changes of concentrations in the closed system do not exert any control on fluxes. Combination with the [[TIP2k-Module| Titration-Injection microPump (TIP2k)]] allows operation with programmable titration regimes and at quasi steady states, yielding an expanded flexibility in experimental design by combining the technical advantages of closed and open systems approaches.
|description=A system is in a '''steady state''' if the levels of a specific variable (''e.g.'' O<sub>2</sub> flux, H<sub>2</sub>O<sub>2</sub> flux, mitochondrial membrane potential) in the [[system]] do not change over time. [[High-resolution respirometry| High-resolution respirometry]] allows for the measurement of several parameters (''e.g.'' O<sub>2</sub> flux, H<sub>2</sub>O<sub>2</sub> flux, mitochondrial membrane potential) at pseudo-steady states, when changes of [[concentration]]s in the [[closed system]] do not exert any control on fluxes. Combination with the [[TIP2k-Module| Titration-Injection microPump (TIP2k)]] allows operation with programmable titration regimes at steady-state oxygen concentration (oxystat mode) or steady-state pH (pH-stat more), yielding an expanded flexibility in experimental design by combining the technical advantages of closed and [[open system]]s approaches.
|info=[[Gnaiger 2000 Proc Natl Acad Sci U S A]], [[Gnaiger 2001 Respir Physiol]], [[Harrison 2015 J Appl Physiol]]  
|info=[[Gnaiger 2000 Proc Natl Acad Sci U S A]], [[Gnaiger 2001 Respir Physiol]], [[Harrison 2015 J Appl Physiol]]  
}}
}}
__TOC__
__TOC__
  Communicated by [[Doerrier C]] (2020-04-20) last update 2020-05-28
  Communicated by [[Doerrier C]] 2020-04-20, last update by [[Gnaiger E]] 2020-06-02
 
== Hyphenation: Steady state or steady-state? ==
:::: Hyphenate if steady-state concentrations are concerned, but do not hyphenate when measurements are made at steady state. - ''See'' https://english.stackexchange.com/questions/29333/hyphenating-steady-state
 


== DatLab oxygen flux: performance and data analysis ==
== DatLab oxygen flux: performance and data analysis ==
::{{Template:Steady state}}


:::: Oxygen fluxes should stabilize — reaching a constant value of the rate — before proceeding with the next titration in the SUIT protocol. The following DatLab traces illustrate examples of stable and unstable respiratory rates:
=== OXPHOS state ===
<gallery mode=default perrow=2 widths="600px" heights="400px">
File:ADP_no_steady_state_O2flux_01.png | '''Figure 1'''. Oxygen flux per volume (right axis, red trace) is not stable in the [[OXPHOS capacity| OXPHOS state]] (2D). Consequently, OXPHOS capacity is underestimated. The addition of cytochrome ''c'' (2c), if stability has not yet been reached in the OXPHOS state, leads to an overestimation of the [[Cytochrome c control factor|cytochrome ''c'' effect]], since the increase in the oxygen flux is not due to the cytochrome ''c'' addition, but instead because flux increases further over time (see Figure 2 for more detail).
File:ADP_no_steady_state_O2flux_02.png | '''Figure 2'''. Illustration of (''1'') the underestimation of OXPHOS capacity (2D), and (2) the overestimation of the [[Cytochrome c control factor|cytochrome ''c'' effect]]. The increase of oxygen flux is indicated by the straight line (from 2D to 2c) is not due to the cytochrome ''c'' addition. More time would have been requred to reach a stable flux before step 2c.


== Hyphenation: Steady state or steady-state? ==
File:ADP_steady_state_O2flux_01.png | '''Figure 3'''. Oxygen flux is stable in 2D, therefore a proper result on [[OXPHOS capacity]] is obtained. In this case, the addition of cytochrome ''c''  (2c) does not lead to an overestimation of the [[cytochrome c control factor]].
:::: Hyphenate if steady-state concentrations are concerned, but do not hyphenate when measurements are made at steady state. - ''See'' https://english.stackexchange.com/questions/29333/hyphenating-steady-state
 
File:ADP_steady_state_O2flux_02.png | '''Figure 4'''. Oxygen flux may need time to stabilize (see 2D). Stabilization time is a property of the mitochondrial sample and varies in different pathophysiological states. Stability of flux can be evaluated with the O2k and DatLab at high-resolution by real-time display of oxygen flux (red line). Oxygen concentration (blue line) may appear to show a sufficiently stable slope, while the actual (negative) slope shown by the red line yields the required sensitivity for evaluation of flux in a respiratory 'steady state'. It is important to wait until a steady state is reached to avoid underestimation of respiratory fluxes. Oxygen concentrations may decline below a lower limit in the closed system, in which case a reoxygenation must be performed by intermittently opening the chamber. An instrumental stabilization time must be taken into account after closing the chamber, to avoid an artefact of overestimation of respiratory flux. Therefore, after a reoxygenation it is equally important to wait until an instrumental steady state is reached for measurement of flux.
|-
</gallery>
 
 
=== After addition of inhibitors ===
 
<gallery mode=default perrow=2 widths="600px" heights="400px">
File:Rot_steady_state_O2flux_02.png | '''Figure 5'''. [[Rotenone]] (Complex I inhibitor) addition in the presence of [[NS-pathway control state|NS-linked substrates]] (PGMS) and uncoupler in [[ET-capacity|ET-state]] (NS<sub>''E''</sub>) allows for measurement of [[Succinate-pathway|S-pathway]] capacity in the ET state (S<sub>''E''</sub>, 6Rot). In many cases, inhibition of flux by rotenone is very fast as shown by a quick transition to a stable flux in the inhibited respiratory state.
 
File:Rot_steady_state_O2flux_01.png | '''Figure 6'''. Inhibition by rotenone (or other inhibitors, ''e.g.'' [[Antimycin A]]) may require a long time until a new steady respiratory state is reached. This is observed particulary in permeabilized muscle fibers, but may apply to other [[MitoPedia: Sample preparations|mitochondrial preparations]]). It is important to wait until a stable flux is reached to avoid overestimation of respiratory fluxes.
|-
</gallery>




Line 25: Line 49:
|order=ascending
|order=ascending
}}
}}
 
{{Keywords: System}}


{{MitoPedia concepts
{{MitoPedia concepts

Revision as of 07:49, 2 June 2020


high-resolution terminology - matching measurements at high-resolution


Steady state

Description

A system is in a steady state if the levels of a specific variable (e.g. O2 flux, H2O2 flux, mitochondrial membrane potential) in the system do not change over time. High-resolution respirometry allows for the measurement of several parameters (e.g. O2 flux, H2O2 flux, mitochondrial membrane potential) at pseudo-steady states, when changes of concentrations in the closed system do not exert any control on fluxes. Combination with the Titration-Injection microPump (TIP2k) allows operation with programmable titration regimes at steady-state oxygen concentration (oxystat mode) or steady-state pH (pH-stat more), yielding an expanded flexibility in experimental design by combining the technical advantages of closed and open systems approaches.


Reference: Gnaiger 2000 Proc Natl Acad Sci U S A, Gnaiger 2001 Respir Physiol, Harrison 2015 J Appl Physiol

Communicated by Doerrier C 2020-04-20, last update by Gnaiger E 2020-06-02

Hyphenation: Steady state or steady-state?

Hyphenate if steady-state concentrations are concerned, but do not hyphenate when measurements are made at steady state. - See https://english.stackexchange.com/questions/29333/hyphenating-steady-state


DatLab oxygen flux: performance and data analysis

Oxygen fluxes should stabilize — reaching a constant value of the rate — before proceeding with the next titration in the SUIT protocol. The following DatLab traces illustrate examples of stable and unstable respiratory rates:

OXPHOS state


After addition of inhibitors


References

Bioblast linkReferenceYear
Chance B, Williams GR (1955) Respiratory enzymes in oxidative phosphorylation: III. The steady state. J Biol Chem 217:409-27.1955
Donnelly C, Komlódi T, Cecatto C, Cardoso LHD, Compagnion AC, Matera A, Tavernari D, Zanou N, Kayser B, Gnaiger E, Place N (2023) Functional hypoxia reduces mitochondrial calcium uptake. MitoFit Preprints 2023.2. https://doi.org/10.26124/mitofit:2023-00022024-11-17 published in Redox Biol.2023
Gnaiger E (1993) Nonequilibrium thermodynamics of energy transformations. Pure Appl Chem 65:1983-2002. http://dx.doi.org/10.1351/pac1993650919831993
Gnaiger E (2001) Bioenergetics at low oxygen: dependence of respiration and phosphorylation on oxygen and adenosine diphosphate supply. https://doi.org/10.1016/S0034-5687(01)00307-32001
Gnaiger E et al ― MitoEAGLE Task Group (2020) Mitochondrial physiology. Bioenerg Commun 2020.1. https://doi.org/10.26124/bec:2020-0001.v12020
Gnaiger E, Méndez G, Hand SC (2000) High phosphorylation efficiency and depression of uncoupled respiration in mitochondria under hypoxia. Proc Natl Acad Sci U S A 97:11080-5. https://doi.org/10.1073/pnas.97.20.110802000
Harrison DK, Fasching M, Fontana-Ayoub M, Gnaiger E (2015) Cytochrome redox states and respiratory control in mouse and beef heart mitochondria at steady-state levels of hypoxia. J Appl Physiol 119:1210-8. https://doi.org/10.1152/japplphysiol.00146.20152015


Questions.jpg


Click to expand or collaps
Bioblast links: System - >>>>>>> - Click on [Expand] or [Collapse] - >>>>>>>



MitoPedia concepts: "MitoFit Quality Control System" is not in the list (MiP concept, Respiratory state, Respiratory control ratio, SUIT concept, SUIT protocol, SUIT A, SUIT B, SUIT C, SUIT state, Recommended, ...) of allowed values for the "MitoPedia concept" property. MitoFit Quality Control System"MitoFit Quality Control System" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property. 


MitoPedia methods: Respirometry, Fluorometry, Spectrophotometry 


MitoPedia O2k and high-resolution respirometry: DatLab