Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Template talk:Next oroboros ecosystem agenda"

From Bioblast
 
Line 14: Line 14:
| width="110" align="center" | [[Image:O2k-Support.jpg|70px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Red-loss of data.png|25px|Warning: loss of data]]
| width="110" align="center" | [[Image:O2k-Support.jpg|70px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Red-loss of data.png|25px|Warning: loss of data]]
|'''Did you know that the proper use of TIP2k-Filter Papers may avoid an unstable O2 slope neg. signal during Instrumental background correction?''' <br>
|'''Did you know that the proper use of TIP2k-Filter Papers may avoid an unstable O2 slope neg. signal during Instrumental background correction?''' <br>
- »[https://wiki.oroboros.at/index.php/Oxygen_flux_-_instrumental_background#Unstable_O2_slope_neg._signal_in_O2_instrumental_BG Instrumental background]« and »[[TIP2k Filter Papers]]«
- »[[Oxygen_flux_-_instrumental_background#Unstable_O2_slope_neg._signal_in_O2_instrumental_BG|Instrumental background]]« and »[[TIP2k Filter Papers]]«
|}
|}
:::: ''See the scheme'':
:::: ''See the scheme'':
Line 20: Line 20:
[[Image:TEMPLATE ALERT.png|none|900px|Agenda/Alerts body text format]]
[[Image:TEMPLATE ALERT.png|none|900px|Agenda/Alerts body text format]]


== Bioblast alert 2020 ==
Prep for circular done here: [[Talk:Bioblast alert 2020]]


== MitoPedia alert ==
== MitoPedia alert ==
 
::: Example:
 
=== Next ===
*'''Sept-03 Th'''
:{|
:{|
| width="110" align="center" | [[File:MitoPedia.jpg|left|80px|MitoPedia|link=MitoPedia]]
| width="110" align="center" | [[File:MitoPedia.jpg|left|80px|MitoPedia|link=MitoPedia]]
|''' How to interpret [[hydrogen peroxide]] fluxes in [[permeabilized muscle fibers]] (pfi) in relation to the high oxygen regime used? '''<br>
|''' Measuring fatty acid oxidation (FAO)-linked respiration requires a low concentration of malate '''<br>
In pfi, [[reactive oxygen species]] (ROS) production may be artificially increased by high oxygen pressures, but high oxygen concentrations are needed to avoid oxygen limitation. Consequently, pfi may not be an optimum model for studies of ROS production.<br>
In the absence of malate, accumulation of Acetyl-CoA inhibits FAO. <br>
- »'''[[Permeabilized_muscle_fibers#Oxygen_dependence_of_ROS_production_-_are_permeabilized_fibers_a_valid_model.3F|Oxygen dependence of ROS production in pfi]]
- »'''[[Fatty acid oxidation pathway control state]]'''«, »'''[https://www.bioblast.at/index.php/Gnaiger_2020_BEC_MitoPathways Mitochondrial Pathways: Chapter 5]'''« <br>
- communicated by »[[Cecatto Cristiane]]« and »[[Cardoso Luiza]]«
|}
|}
:::*Commment by Timi: is this a MitoPedia or an Open Support alert?




:{|
=== Next ===
| width="110" align="center" | [[File:MitoPedia.jpg|left|80px|MitoPedia|link=MitoPedia]]
|''' What are observed high [[hydrogen peroxide]] (H<sub>2</sub>O<sub>2</sub>) fluxes telling you about high oxygen regimes used for experiments with [[permeabilized muscle fibers]] (pfi)?  '''<br>
In experiments with pfi, the [[Permeabilized_muscle_fibers#High_oxygen_in_permeabilized_fibers_versus_oxygen_limitation_under_hypoxia|high oxygen pressures]] used may artificially increase H<sub>2</sub>O<sub>2</sub> production. However, the high oxygen concentrations are needed to avoid oxygen limitation. Consequently, pfi may not be an optimum model for studies of H<sub>2</sub>O<sub>2</sub> production.<br>
- »'''[[Permeabilized_muscle_fibers#Oxygen_dependence_of_ROS_production_-_are_permeabilized_fibers_a_valid_model.3F|Oxygen dependence of ROS production in pfi]]'''«
|}
:::* Luiza: I would keep as MitoPedia - we don't have the "open support" badge at this page.
 
Version (03)
:{|
| width="110" align="center" | [[File:MitoPedia.jpg|left|80px|MitoPedia|link=MitoPedia]]
|''' What are observed high [[hydrogen peroxide]] (H<sub>2</sub>O<sub>2</sub>) fluxes telling you about high oxygen regimes used for experiments with [[permeabilized muscle fibers]] (pfi)?  '''<br>
In experiments with pfi, the [[Permeabilized_muscle_fibers#High_oxygen_in_permeabilized_fibers_versus_oxygen_limitation_under_hypoxia|high oxygen pressures]] used may artificially increase H<sub>2</sub>O<sub>2</sub> production. However, the high oxygen concentrations are needed to avoid oxygen limitation. Consequently, pfi may not be an optimum model for studies of H<sub>2</sub>O<sub>2</sub> production.<br>
- »'''[[Permeabilized_muscle_fibers#Oxygen_dependence_of_ROS_production_-_are_permeabilized_fibers_a_valid_model.3F|Oxygen dependence of ROS production in pfi]]'''«
|}


=== Under construction ===


*'''Sep-10 Th'''
on hold until the page is updated
:{|
:{|
| width="110" align="center" | [[File:MitoPedia.jpg|left|80px|MitoPedia|link=MitoPedia]]
| width="100" align="center" |[[File:FAT4BRAIN logo.png|right|80px|link=https://wiki.oroboros.at/index.php/FAT4BRAIN|FAT4BRAIN]]
|''' What is the limitation of State 3 respiration compared to [[OXPHOS capacity]]? '''<br>
|'''A FAO-mito-CNS platform to help fatty acid-related respiration measurements was developed in the FAT4BRAIN project''' <br>
OXPHOS capacity allows you to measure maximal respiratory capacity in the OXPHOS state in the presence of saturating concentration of ADP, P<sub>i</sub>, fuel substrates and O<sub>2</sub>. However, State 3 can lead to underestimation of OXPHOS capacity and overestimation of [[excess E-P capacity]] creating experimental artefacts. <br>
- » [[FAT4BRAIN_FAO-mito-CNS_platform|FAT4BRAIN FAO-mito-CNS platform]] «
- »'''[[BEC_2020.1_doi10.26124bec2020-0001.v1|BEC: Mitochondrial physiology]]'''« - Table 3. <br>
- communicated by »[[Cecatto Cristiane]]« and » [[Komlodi Timea]] «
|}
|}


*'''Sep-17 Th'''
== O2k-Brief alert ==
:::* Example:
:{|
:{|
| width="110" align="center" | [[File:MitoPedia.jpg|left|80px|MitoPedia|link=MitoPedia]]
| width="100" align="center" | [[File:O2k-brief.png|45px|link=http://wiki.oroboros.at/index.php/O2k-brief|O2k-brief repository]]
|''' Did you know that the [[free ROUTINE activity]] allows you to indirectly measure ATP production in living cells?'''<br>
|'''Antitumoral properties of triterpenic acid functionalized gold nanoparticles arise from decreasing mitochondrial respiration''' <br>
The [[free ROUTINE activity]] is ROUTINE respiration corrected for LEAK respiration which is available for phosphorylation of ADP to ATP in living cells.<br>
* Mioc M, Mioc A, Racoviceanu R, Ghiulai R, Prodea A, Milan A, Barbu Tudoran L, Oprean C, Ivan V, Șoica C (2023) The antimelanoma biological assessment of triterpenic acid functionalized gold nanoparticles. [[Mioc 2023 Molecules|»Bioblast link«]]
- »'''[[SUIT-003 O2 ce D009]]
|}
Suggestion 2 (Luiza):
:{|
| width="110" align="center" | [[File:MitoPedia.jpg|left|80px|MitoPedia|link=MitoPedia]]
|''' Did you know that the [[free ROUTINE activity]] allows assessing the respiratory activity available for phosphorylation of ADP to ATP in [[living cells]]?'''<br>
[[SUIT]] protocols from the [[SUIT-003]] family will guide you through the titrations needed to analyse [[free ROUTINE activity]].<br>
- »'''[[SUIT-003 O2 ce D009]]'''« and '''»[[SUIT-003 O2 ce-pce D020]]'''«
|}
|}
=== Next ===


'''* Sept-24 Th'''
== O2k-Publications alert ==
:Version 1 (Timi)
:{|
| width="110" align="center" | [[File:MitoPedia.jpg|left|80px|MitoPedia|link=MitoPedia]]
|''' Did you know that you can measure reverse electron flow from Complex II towards Complex I in mitochondrial preparations using high-resolution respirometry?'''<br>
RET stands for [https://wiki.oroboros.at/index.php/Reverse_electron_flow_from_CII_to_CI reverse electron flow] when the electrons are transferred back from [[Complex II]] via the [[Q-junction]] towards [[Complex I]] at high [[mt-membrane potential]], which results in high [[hydrogen peroxide]] production in some [[mitochondrial preparations]].  <br>
- »'''[[SUIT-026]]
|}
:Version 2 (Timi)
:{|
| width="110" align="center" | [[File:MitoPedia.jpg|left|80px|MitoPedia|link=MitoPedia]]
|''' Did you know that you can measure reverse electron flow from Complex II towards Complex I in mitochondrial preparations using [[Amplex UltraRed]] assay?'''<br>
RET stands for [https://wiki.oroboros.at/index.php/Reverse_electron_flow_from_CII_to_CI reverse electron flow] when the electrons are transferred back from [[Complex II]] via the [[Q-junction]] towards [[Complex I]] at high [[mt-membrane potential]], which results in high [[hydrogen peroxide]] production in some [[mitochondrial preparations]].  <br>
- »'''[[SUIT-026]]
|}


:Suggestion 2 (Luiza) - from version 2:
:::* Example:  
:{|
:{|
| width="110" align="center" | [[File:MitoPedia.jpg|left|80px|MitoPedia|link=MitoPedia]]
| width="100" align="center" |[[Image:O2k-Publications.jpg|70px|link=http://wiki.oroboros.at/index.php/O2k-Publications:_Topics |O2k-Publications in the MiPMap]]
|''' Did you know that you can measure [[ROS]] production related to reverse electron flow from Complex II towards Complex I in mitochondrial preparations using [[Amplex UltraRed]] assay?'''<br>
|'''"Mitochondria–nucleus communication and its integration within the maintenance of cellular homeostasis constitute key determinants of cellular fate and organism health in the context of cellular stress, homeostasis perturbation, and disease"''' <br>
The [[Reverse_electron_flow_from_CII_to_CI|reverse electron flow]], also called reverse electron transfer (RET), happens when the electrons are transferred from [[Complex II]] towards [[Complex I]] via the [[Q-junction]] at high [[mt-membrane potential]]. This phenomenon results in high [[hydrogen peroxide]] production in some [[mitochondrial preparations]]. The SUIT-026 protocol was designed to investigte this effect. <br>
* Temelie M, Talpur R, Dominguez-Prieto M, Dantas Silva A, Cenusa C, Craciun L, Savu DI, Moisoi N (2023) Impaired integrated stress response and mitochondrial integrity modulate genotoxic stress impact and lower the threshold for immune signalling. [[Temelie 2023 Int J Mol Sci|»Bioblast link«]]
- »'''[[SUIT-026]]'''«
:from the O2k-Network »[[UK Leicester Moisoi N]]«
|}
|}
: Comment (Timi): Should it be a SUIT protocol alert instead of the MitoPedia alert?
== O2k-Brief alert ==
=== Next ===


* '''Sep-04 Fr''' (pending publication of Luiza's video communication)
:{|
| width="100" align="center" | [[File:O2k-brief.png|45px|link=http://wiki.oroboros.at/index.php/O2k-brief|O2k-brief repository]]
|'''Measuring ATP-ADP exchange via [[adenine nucleotide translocase]] (ANT) using the fluorophore [[Magnesium Green]] (MgG)''' <br>
: from the O2k-Network »[[HU Budapest Chinopoulos C]]« <br>
* Chinopoulos C, Kiss G, Kawamata H, Starkov AA (2014) Measurement of ADP-ATP exchange in relation to mitochondrial transmembrane potential and oxygen consumption. Methods Enzymol 542:333-48.  [[Chinopoulos 2014 Methods Enzymol|»Bioblast link«]]
|}
== O2k-Publications alert ==
===='''Author names of O2k-Publications/ Brief for the Agenda vs Bioblast''' ====  
===='''Author names of O2k-Publications/ Brief for the Agenda vs Bioblast''' ====  
::1.Oroboros Ecosystem Agenda: SOP: Surname with long version and First name with short version. Please, see: [https://wiki.oroboros.at/index.php/File:TEMPLATE_ALERT.png Template alerts].
:::Example: [https://wiki.oroboros.at/index.php/O2k-Publications_alert Oroboros Ecosystem Agenda example]
:::This means that '''we have to edit manually the author names''' within the O2k-Publications/ Brief alerts (i.e., Antunes Diana (from Bioblast) to Antunes D (to Agenda entries)) if they are long or copy from the gray box.
::2.Bioblast: SOP: [https://www.bioblast.at/index.php/Form:Publication] – examples are available using both Surname and First name with long version (e.g., Antunes Diana). If in Bioblast the authors are with short surname in the links please update it to complete surname, guidelines are below.


__NOTOC__ [[File:Expand.png|right|25px|Click to expand or collaps]]
__NOTOC__ [[File:Expand.png|right|25px|Click to expand or collaps]]
Line 159: Line 101:
</div>
</div>


=== Next ===
May 22nd


=== Next ===
* '''Sep-15 Tu''' - World Lymphoma Awareness Day
:{|
:{|
| width="100" align="center" |[[Image:O2k-Publications.jpg|70px|link=http://wiki.oroboros.at/index.php/O2k-Publications:_Topics |O2k-Publications in the MiPMap]]
| width="100" align="center" |[[Image:O2k-Publications.jpg|70px|link=http://wiki.oroboros.at/index.php/O2k-Publications:_Topics |O2k-Publications in the MiPMap]]
|'''Classical Hodgkin lymphoma cells are highly dependent on oxidative phosphorylation'''<br>
|'''"We have identified a circadian clock phase-dependent change in Complex I coupling efficiency, demonstrating for the first time a mitochondria–clock interaction in the hooded seal."''' <br>
:from the O2k-Network »[[DE Frankfurt Droese S]]«, »[[DE Frankfurt Wittig I]]« and »[[NL Nijmegen Brandt U]]«
* Ciccone C, Kante F, Folkow LP, Hazlerigg DG, West AC, Wood SH (2024) Circadian coupling of mitochondria in a deep-diving mammal. [[Ciccone 2024 J Exp Biol|»Bioblast link«]]
*Birkenmeier K, Droese S, Wittig I, Winkelmann R, Käfer V, Doering C, Hartmann S, Wenz T, Reichert AS, Brandt U, Hansmann ML (2015) Hodgkin and Reed-Sternberg cells of classical Hodgkin lymphoma are highly dependent on oxidative phosphorylation. Int J Cancer 138:2231-46. [[Birkenmeier 2015 Int J Cancer|»Bioblast link«]]
:from the O2k-Network »[[NO Tromsoe Wood SH]]«
|}
|}


==  MiPNet ==
:::* Example:
:{|
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
|''' "No bubbles should be trapped in the electrolyte reservoir after membrane application and mounting"'''<br>


* '''Sep-21 Mo''' - World Alzheimer's Day
- »'''[[MiPNet28.10 SmartPOS-service]]'''«<br>
:{|
- communicated by »[[Timon-Gomez Alba]]« and »[[]]«
| width="100" align="center" |[[Image:O2k-Publications.jpg|70px|link=http://wiki.oroboros.at/index.php/O2k-Publications:_Topics |O2k-Publications in the MiPMap]]
|'''Sentence'''<br>
:from the O2k-Network »[[link]]«
*Reference [[add link here|»Bioblast link«]]
|}
|}


=== Next ===
May 2nd


* '''Sep-29 Tu''' - World Heart Day
:{|
:{|
| width="100" align="center" |[[Image:O2k-Publications.jpg|70px|link=http://wiki.oroboros.at/index.php/O2k-Publications:_Topics |O2k-Publications in the MiPMap]]
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
|'''Sentence'''<br>
|''' "In respirometric studies on blood cells, the purity of cell preparation should always be emphasized and documented." '''<br>
:from the O2k-Network »[[link]]«
- »'''[[MiPNet21.17 BloodCellsIsolation]]'''«<br>
*Reference [[add link here|»Bioblast link«]]
- communicated by »[[Timon-Gomez Alba]]« and »[[Baglivo Eleonora]]«
|}
|}


==  O2k-Open Support alert ==
==  O2k-Open Support alert ==
 
:::*Examples:
::::* While in Home Office: [[User:Gnaigere|Gnaigere]] ([[User talk:Gnaigere|talk]]) 14:03, 19 March 2020 (CET) https://wiki.oroboros.at/index.php/Talk:O2k-Open_Support_alert  -  Many labs will move to home office mode. In line with our special DL7.4 home office offer (see Agenda today), therefore, I suggest to post in our Agenda '''analysis-linked''' O2k-Open Support cases during this time, and collect real-time operation cases for future releases.
=== Next ===
* '''Sept-07 Mo'''
:{|
:{|
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Yellow-take care.png|25px|Info: take care]]
| '''Why it is necessary to perform multiple [[hydrogen peroxide]] calibrations when using the [[Amplex UltraRed]] assay?'''<br>
|'''Does your polarographic oxygen sensor (POS) need a deep clean?'''<br>
Multiple calibration is needed because the [[sensitivity]] of the Amplex UltraRed assay towards H<sub>2</sub>O<sub>2</sub> changes during the experiment. This change may be the function of: 1) experimental time, 2) changes in the optical properties, 3) radical scavenging capacity owing to the sample, and 4) concentration of the accumulating resorufin (UltroxRed in the case of Amplex UltraRed). Therefore, it is recommended to perform H<sub>2</sub>O<sub>2</sub> calibration before sample addition, after sample addition and multiple times during the experiment. <br>
A POS with a very dark anode might need several rounds of ammonia cleaning, possibly including prolonged exposure overnight to restore performance specifications.  
- » [https://wiki.oroboros.at/index.php/Komlodi_2018_Methods_Mol_Biol Komlodi 2018 Methods Mol Biol]« and » [https://www.bioblast.at/index.php/MitoPedia:_SUIT#SUIT_A_FluoRespirometry:_recommended_protocols  SUIT A FluoRespirometry: recommended protocols]
<br>
- »'''[[MiPNet19.18B POS-service|POS service]]'''«<br>
- communicated by »[[Cecatto Cristiane]]« and »[[Leo Elettra]]«
|}
|}
Suggestion 2 (Luiza):
:{|
:{|
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Red-loss of data.png|25px|Warning: loss of data]]  
| '''Why it is necessary to perform multiple [[hydrogen peroxide]] calibrations when using the [[Amplex UltraRed]] (AmR) assay?'''<br>
|'''Did you know that a humid environment and/or liquid spillage may lead to a high raw POS signal [V]?'''<br>
Multiple calibration is needed because the [[sensitivity]] of the Amplex UltraRed assay towards H<sub>2</sub>O<sub>2</sub> changes during the experiment. This change may be the function of: 1) experimental time, 2) changes in the optical properties, 3) radical scavenging capacity owing to the sample, and 4) concentration of the accumulating resorufin (UltroxRed in the case of Amplex UltraRed). Therefore, it is recommended to perform H<sub>2</sub>O<sub>2</sub> calibration before sample addition, after sample addition and multiple times during the experiment. <br>
See how to clean and dry the electrical connections of the OroboPOS-Connector.<br>
- »[[Amplex_UltraRed#Calibration_with_H2O2|Amplex UltraRed Calibration with H<sub>2</sub>O<sub>2</sub>]]« and »[[Komlodi 2018 Methods Mol Biol]]« <br>
- »'''[[OroboPOS-Connector#Cleaning_the_electrical_connections|Cleaning the electrical connections]]'''«<br>
 
- communicated by »[[Cecatto Cristiane]]« and »[[Baglivo Eleonora]]«
The DLPs for AmR [[SUIT]] protocols already come with multiple steps of H<sub>2</sub>O<sub>2</sub> titrations for calibration implemented. <br>
- » [[MitoPedia:_SUIT#SUIT_A_FluoRespirometry:_recommended_protocols|SUIT A FluoRespirometry: recommended protocols]]«
|}
|}
Suggestion 3 (Timi):
:{|
:{|
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
| '''Why it is necessary to perform multiple [[hydrogen peroxide]] calibrations when using the [[Amplex UltraRed]] (AmR) assay?'''<br>
|''' Unusual stirrer bar rotation? '''<br>
Multiple calibration is needed because the [[sensitivity]] of the Amplex UltraRed assay to H<sub>2</sub>O<sub>2</sub> changes during the experiment. This change may be the function of: 1) experimental time, 2) changes in the optical properties, 3) radical scavenging capacity of the sample, and 4) concentration of the accumulating resorufin (UltroxRed in the case of Amplex UltraRed). Therefore, it is recommended to perform H<sub>2</sub>O<sub>2</sub> calibration before sample addition, after sample addition and multiple times during the experiment. <br>
A “jumping” stirrer or a slow rotation of the stirrer bar may indicate a problem either with the stirrer itself or with the cleaning of the glass chamber.  
- »[[Amplex_UltraRed#Calibration_with_H2O2|Amplex UltraRed Calibration with H<sub>2</sub>O<sub>2</sub>]]« and »[[Komlodi 2018 Methods Mol Biol]]« <br>
<br>
 
- »'''[https://wiki.oroboros.at/index.php/Stirrer-Bar%5Cwhite_PVDF%5C15x6_mm#Technical_support Stirrer bar - technical support]'''«<br>
The DLPs for AmR [[SUIT]] protocols already come with multiple steps of H<sub>2</sub>O<sub>2</sub> calibrations implemented. <br>
- communicated by »[[Baglivo Eleonora]]« and »[[Grings Mateus]]«
- » [[MitoPedia:_SUIT#SUIT_A_FluoRespirometry:_recommended_protocols|SUIT A FluoRespirometry: recommended protocols]]«
|}
|}


=== Next ===


* '''Sept-14 Mo'''
== O2k-Feedback alert ==
:::* Example (if the person has a profile, link the name to the profile with [[Cecatto C| Cristiane Cecatto]]:
:{|
:{|
| width="110" align="center" | [[File:MitoPedia.jpg|left|80px|MitoPedia|link=MitoPedia]]
| width="110" align="center" | [[Image:O2k-Feedback.jpg|60px|link=https://wiki.oroboros.at/index.php/O2k-Feedback |O2k-Feedback]]
|''' Why [[Amplex UltraRed]] cannot be used to monitor H<sub>2</sub>O<sub>2</sub> flux with liver homogenate?'''<br>
|''' ''“Thank you very much for your thorough help. I appreciate the time you took to provide me with all the answers and supportive literature to realize the potential of the O2k-respirometer in bioenergetics research”'''''<br>
Liver homogenate cannot be used with the AmR technique to measure H<sub>2</sub>O<sub>2</sub> flux, because of the optical properties of the cytosol.<br>
Badr Ibrahim, PhD from Betterhumans Inc., US
- »'''[[ADD LINK HERE|Amplex UltraRed Calibration with H<sub>2</sub>O<sub>2</sub>]]'''« and »'''[[Makrecka-Kuka_2015_Biomolecules|Makrecka-Kuka 2015 Biomolecules]]'''«
<br>
- »'''[[O2k-Feedback]]'''«<br>
|}
|}
Suggestion 1 (Timi):
:{|
:{|
| width="110" align="center" | [[File:MitoPedia.jpg|left|80px|MitoPedia|link=MitoPedia]]
| width="110" align="center" | [[Image:O2k-Feedback.jpg|60px|link=https://wiki.oroboros.at/index.php/O2k-Feedback |O2k-Feedback]]
|''' Why the [[Amplex UltraRed]] assay cannot be used to monitor H<sub>2</sub>O<sub>2</sub> flux with liver homogenate?'''<br>
|''' ''“Thank you very much for your thorough help. I appreciate the time you took to provide me with all the answers and supportive literature to realize the potential of the O2k-respirometer in bioenergetics research”'''''<br>
[https://wiki.oroboros.at/index.php/Tissue_homogenate  Liver homogenate] cannot be used with the AmR technique to measure H<sub>2</sub>O<sub>2</sub> flux, because of the optical properties of the cytosol.<br>
Badr Ibrahim, PhD from the O2k-Network »[[UK Leicester Moisoi N]<br>
- » '''[https://wiki.oroboros.at/index.php/MiPNet18.05_Amplex-Mouse-heart MiPNet18.05 ]'''« and »'''[[Makrecka-Kuka_2015_Biomolecules|Makrecka-Kuka 2015 Biomolecules]]'''«
- »'''[[O2k-Feedback]]'''«<br>
|}
|}


Suggestion 2 (Lisa) - O2k-Open support alert
=== Next ===
 
== MitoFit Preprints ==
:::* Example:
:{|
:{|
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Red-loss of data.png|25px|Info: improve]]
| width="100" align="center"|[[Image:BEC-logo.png|100px|link=https://www.bioenergetics-communications.org/index.php/bec |Bioenergetics Communications]]
| '''Why the [[Amplex UltraRed]] assay cannot be used to monitor H<sub>2</sub>O<sub>2</sub> flux with liver homogenate?'''<br>
|'''From preprint to BEC manuscript with published Open Peer Reviews:'''<br>
Liver [[Tissue_homogenate|homogenate]] cannot be used with the AmR technique to measure H<sub>2</sub>O<sub>2</sub> flux, because of the optical properties of the cytosol. <br>
*Komlódi T, Sobotka O, Gnaiger E (2021) Facts and artefacts on the oxygen dependence of hydrogen peroxide production using Amplex UltraRed. Bioenerg Commun 2021.4. [[doi:10.26124/BEC:2021-0004]]
- » [[MiPNet18.05_Amplex-Mouse-heart|MiPNet18.05]]« and »[[Makrecka-Kuka_2015_Biomolecules|Makrecka-Kuka 2015 Biomolecules]]«
:from the O2k-Network »[[AT Innsbruck Oroboros]]«  
|}
|}


=== Removed for correction ===
=== Next ===
 
== Under discussion ==
 
This one needs an update of the Bioblast page and clarification of MiPNet06.03


:{|
:{|
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Red-loss of data.png|25px|Warning: loss of data]]
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
|'''Do you perform the ''leaky chamber test'' after chamber assembly? '''<br>
|''' Did you enter the correct oxygen solubility factor in DatLab?'''<br>
An unnoticed leak from the chamber may affect your data, therefore we recommend performing the ''Leaky chamber test'' - especially after chamber reassembly. <br>
The oxygen solubility factor of the incubation medium, F<sub>M</sub>, expresses the effect of the salt concentration on oxygen solubility relative to pure water. The correct oxygen solubility factor of your experimental medium or buffer needs to be entered in DatLab for proper calculation of the oxygen concentration.
- »[[Talk:O2k-Chamber_MitoPedia#Leaky_Chamber|Leaky chamber test]]« and » https://intern.oroboros.at/index.php/Overnight_test_after_O2k-chamber_assembly«
<br>
- »'''[[Oxygen solubility factor|Oxygen solubility factor]]'''«<br>
- communicated by »[[Schmitt Sabine]]« and »[[ ]]«
 
|}
|}


* '''Aug-17 Mo''' 
This one needs a BioBlast link:
 
:{|
:{|
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Red-loss of data.png|25px|Warning: loss of data]]
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
|'''Have you observed an 'O<sub>2</sub> slope neg.' > 4 pmol∙s<sup>−1</sup>∙mL<sup>−1</sup> in the closed 2 mL chamber at air saturation without a biological sample? '''<br>
|''' When filling in the volume of uncoupler in the DatLab mark or the excel template, should one enter the total volume added or the volume to get to the highest flux?'''<br>
This may be due to [[biological contamination]] of the medium or the O2k-Chamber. <br>
The volume added until the mark, equal to the highest flux, should be entered. Anything titrated after this mark should be summed to the other volumes before the next mark because this will be considered to calculate the sample dilution.
For further details on how to clean the O2k-Chamber properly, see: <br>
<br>
- » [[O2k-Chamber_MitoPedia#Cleaning_the_O2k-Chamber|Cleaning of the O2k-Chamber]]«<br>
- »'''[[LINK|LINK]]''' and '''[[MiPNet24.06_Oxygen_flux_analysis_-_DatLab_7.4|O<sub>2</sub> flux analysis with DatLab 7.4]]'''«<br>
- communicated by »[[Cardoso Luiza]]« and »[[ ]]«
|}
|}


== O2k-Open Support alert circulars ==
== In preparation ==
== For discussion ==
''Here we discuss suggestions for the Oroboros Ecosystem Agenda 2020 ('''if''' the specific alert section is yet to be attributed)''


== Removed for correction ==
* '''Nov-30 Mo'''
:{|
:{|
| width="100" align="center" | [[Image:SUIT icon.jpg|80px|link=https://wiki.oroboros.at/index.php/MitoPedia:_SUIT |MitoPedia: SUIT]]  
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Blue-info.png|25px|Info: improve]]
| Controlled stability of the [https://www.oroboros.at/index.php/product/mitokit-cii MitoKit-CII] based on HPLC and LCMS analysis: No degradation of [[MitoKit-CII_MitoPedia| MitoKit-CII]] compounds [[MitoKit-CII/Succinate-nv| MitoKit-CII/Succinate-nv (NV118)]] and [[MitoKit-CII/Malonate-nv| MitoKit-CII/Malonate-nv (NV161)]] for following storage conditions:
|'''Noisy oxygen signal? Check the OroboPOS and OroboPOS-Connector to clean electrical connections.'''<br>
* Proven -80 °C solid stability for more than 3 years (3 years 7 months)
Contaminating grease, salt crystals and moisture can be removed with a dry paper cloth or a paper cloth moistened with water and then absolute ethanol. <br>
* Proven -20 °C solid stability for 1 year
- »[[OroboPOS-Connector#Cleaning_the_electrical_connections |Cleaning the electrical connections]]« <br>
* Proven DMSO stability at room temperature for 1 week
- communicated by »[[Schmitt Sabine]]« and »[[Komlodi Timea]]«
* Proven DMSO stability at -20 °C for 6 months (ongoing)
|}
|}
WGT recommended not to use water for cleaning. Erich introduced water for cleaning to remove salt crystals.


== 2021 ==


::::* 2021-01-06 https://www.jstor.org/stable/1706346?seq=1
:{|
 
| width="110" align="center" | [[Image:O2k-Support.jpg|60px|link=http://wiki.oroboros.at/index.php/O2k-Open_Support |O2k-Open Support]][[File:Red-loss of data.png|25px|Warning: loss of data]]
== Postponed events ==
|'''Do you perform the ''leaky chamber test'' after chamber assembly? '''<br>
 
An unnoticed leak from the chamber may affect your data, therefore we recommend performing the ''Leaky chamber test'' - especially after chamber reassembly. <br>
:::: [[File:FAT4BRAIN logo.png|70px|FAT4BRAIN|link=FAT4BRAIN School Riga LV]] »<big>'''[[FAT4BRAIN School Riga LV | FAT4BRAIN School Riga LV IOC147]]'''</big>«
- »[[Talk:O2k-Chamber_MitoPedia#Leaky_Chamber|Leaky chamber test]]« and » https://intern.oroboros.at/index.php/Overnight_test_after_O2k-chamber_assembly«
 
|}
:::: »<big>'''[[APS2020 Chicago US]]'''</big>«
 
:::: [[Image:O2k-Network.png|70px|O2k-Workshops|link=O2k-Events#Next_O2k-Workshops]] [[MiPNet25.09 IOC San Diego CA US |<big>'''San Diego CA US'''</big>]]
 
::::* Abstracts deadline [https://www.cebitec.uni-bielefeld.de/events/conferences/575-algal-biotech-202  10th Int. CeBiTec Research Conference Advances in Industrial Biotechnology: Prospects and challenges for the development of algal biotechnology]
::::* Notification to oral and poster presenters - »[[MitoEAGLE Summit Obergurgl 2020]]« (2020 Nov 04-07) and »[[MiPschool Obergurgl 2020]]« (2020 Nov 09-11)
::::[[File:Bioenergetics Vienna 2020.jpg|200px |link=Bioenergetics_Vienna_2020#Programme]] '''<big>[[Bioenergetics Vienna 2020]]</big>'''
:::: [[Image:O2k-Workshops.png|70px|O2k-Workshops|link=O2k-Events#Next_O2k-Workshops]] [[MiPNet25.02 IOC Schroecken AT |<big>'''IOC Schroecken AT'''</big>]]
 
::::* '''Registration and late Abstract Deadline''' - »[[MitoEAGLE Summit Obergurgl 2020]]« and »[[MiPschool Obergurgl 2020]]«

Latest revision as of 13:49, 29 April 2024

Antunes Diana (talk) 08:58, 5 May 2020 (CEST) Format for new Agenda/Alerts entries:
 {|
 | logos
 | title in bold <br>
 - link
 |}
 

e.g.,

O2k-Open SupportWarning: loss of data Did you know that the proper use of TIP2k-Filter Papers may avoid an unstable O2 slope neg. signal during Instrumental background correction?

- »Instrumental background« and »TIP2k Filter Papers«

See the scheme:


Agenda/Alerts body text format


MitoPedia alert

Example:
MitoPedia
Measuring fatty acid oxidation (FAO)-linked respiration requires a low concentration of malate

In the absence of malate, accumulation of Acetyl-CoA inhibits FAO.
- »Fatty acid oxidation pathway control state«, »Mitochondrial Pathways: Chapter 5« 
- communicated by »Cecatto Cristiane« and »Cardoso Luiza« 


Next

Under construction

on hold until the page is updated
FAT4BRAIN
A FAO-mito-CNS platform to help fatty acid-related respiration measurements was developed in the FAT4BRAIN project

- » FAT4BRAIN FAO-mito-CNS platform «

O2k-Brief alert

  • Example:
O2k-brief repository Antitumoral properties of triterpenic acid functionalized gold nanoparticles arise from decreasing mitochondrial respiration
  • Mioc M, Mioc A, Racoviceanu R, Ghiulai R, Prodea A, Milan A, Barbu Tudoran L, Oprean C, Ivan V, Șoica C (2023) The antimelanoma biological assessment of triterpenic acid functionalized gold nanoparticles. »Bioblast link«

Next

O2k-Publications alert

  • Example:
O2k-Publications in the MiPMap "Mitochondria–nucleus communication and its integration within the maintenance of cellular homeostasis constitute key determinants of cellular fate and organism health in the context of cellular stress, homeostasis perturbation, and disease"
  • Temelie M, Talpur R, Dominguez-Prieto M, Dantas Silva A, Cenusa C, Craciun L, Savu DI, Moisoi N (2023) Impaired integrated stress response and mitochondrial integrity modulate genotoxic stress impact and lower the threshold for immune signalling. »Bioblast link«
from the O2k-Network »UK Leicester Moisoi N«

Author names of O2k-Publications/ Brief for the Agenda vs Bioblast

Click to expand or collaps

Guidelines to update a reference

When creating an O2k-Publication/Brief alert, it is the responsibility of the author to check if the reference is accordingly to the correct guidelines:

Reference example.png

Correct format for a person called “First Name Surname”:
In the gray box should be “Surname FN” - From where references to be used as O2k-Publication/Brief alerts are copied from.

Gray box reference.png

In the links should be “ Surname First N”

Authors names links reference.png

How to edit:
A) Check if all authors with profiles in Bioblast (blue links) have their profiles with full name. If they have, proceed to next step (B). If not, you need to move it following the steps “How to move a profile” below.
B) Click in “Edit with form”.
C) The gray box is edited in “Reference” and the links are changed in “Author(s)”. Change it accordingly and click in “save page” at the end of the page.

Editing reference.png

How to move a profile (instructions sent by Marija):

So let’s take for example my page: Beno M [1]

As you can see there is a redirect from Beno Marija to Beno M. What has to be done is to switch the content of those pages. Here are the steps:
1. Go to e.g. “Beno M” on edit
2. Click on “Move”
3. Change the new title to the full name of the person. In my case it will be Beno M to Beno Marija

BenoMreference.jpg

4. Now it should look like that:

BenoMarijaReference.png

5. Click on “Move” and leave all the ticked boxes
6.Done
After that you can continue in step B.
If you have any doubt you can contact Cristiane, Marija or Mario.

Next

May 22nd

O2k-Publications in the MiPMap "We have identified a circadian clock phase-dependent change in Complex I coupling efficiency, demonstrating for the first time a mitochondria–clock interaction in the hooded seal."
  • Ciccone C, Kante F, Folkow LP, Hazlerigg DG, West AC, Wood SH (2024) Circadian coupling of mitochondria in a deep-diving mammal. »Bioblast link«
from the O2k-Network »NO Tromsoe Wood SH«

MiPNet

  • Example:
O2k-Open SupportInfo: improve "No bubbles should be trapped in the electrolyte reservoir after membrane application and mounting"

- »MiPNet28.10 SmartPOS-service«
- communicated by »Timon-Gomez Alba« and »[[]]«

Next

May 2nd

O2k-Open SupportInfo: improve "In respirometric studies on blood cells, the purity of cell preparation should always be emphasized and documented."

- »MiPNet21.17 BloodCellsIsolation«
- communicated by »Timon-Gomez Alba« and »Baglivo Eleonora«

O2k-Open Support alert

  • Examples:
O2k-Open SupportInfo: take care Does your polarographic oxygen sensor (POS) need a deep clean?

A POS with a very dark anode might need several rounds of ammonia cleaning, possibly including prolonged exposure overnight to restore performance specifications.
- »POS service«
- communicated by »Cecatto Cristiane« and »Leo Elettra«

O2k-Open SupportWarning: loss of data Did you know that a humid environment and/or liquid spillage may lead to a high raw POS signal [V]?

See how to clean and dry the electrical connections of the OroboPOS-Connector.
- »Cleaning the electrical connections«
- communicated by »Cecatto Cristiane« and »Baglivo Eleonora«

O2k-Open SupportInfo: improve Unusual stirrer bar rotation?

A “jumping” stirrer or a slow rotation of the stirrer bar may indicate a problem either with the stirrer itself or with the cleaning of the glass chamber.
- »Stirrer bar - technical support«
- communicated by »Baglivo Eleonora« and »Grings Mateus«

Next

O2k-Feedback alert

  • Example (if the person has a profile, link the name to the profile with Cristiane Cecatto:
O2k-Feedback “Thank you very much for your thorough help. I appreciate the time you took to provide me with all the answers and supportive literature to realize the potential of the O2k-respirometer in bioenergetics research”

Badr Ibrahim, PhD from Betterhumans Inc., US
- »O2k-Feedback«

O2k-Feedback “Thank you very much for your thorough help. I appreciate the time you took to provide me with all the answers and supportive literature to realize the potential of the O2k-respirometer in bioenergetics research”

Badr Ibrahim, PhD from the O2k-Network »UK Leicester Moisoi N«
- »O2k-Feedback«

Next

MitoFit Preprints

  • Example:
Bioenergetics Communications From preprint to BEC manuscript with published Open Peer Reviews:
  • Komlódi T, Sobotka O, Gnaiger E (2021) Facts and artefacts on the oxygen dependence of hydrogen peroxide production using Amplex UltraRed. Bioenerg Commun 2021.4. doi:10.26124/BEC:2021-0004
from the O2k-Network »AT Innsbruck Oroboros«

Next

Under discussion

This one needs an update of the Bioblast page and clarification of MiPNet06.03

O2k-Open SupportInfo: improve Did you enter the correct oxygen solubility factor in DatLab?

The oxygen solubility factor of the incubation medium, FM, expresses the effect of the salt concentration on oxygen solubility relative to pure water. The correct oxygen solubility factor of your experimental medium or buffer needs to be entered in DatLab for proper calculation of the oxygen concentration.
- »Oxygen solubility factor«
- communicated by »Schmitt Sabine« and »[[ ]]«

This one needs a BioBlast link:

O2k-Open SupportInfo: improve When filling in the volume of uncoupler in the DatLab mark or the excel template, should one enter the total volume added or the volume to get to the highest flux?

The volume added until the mark, equal to the highest flux, should be entered. Anything titrated after this mark should be summed to the other volumes before the next mark because this will be considered to calculate the sample dilution.
- »LINK and O2 flux analysis with DatLab 7.4«
- communicated by »Cardoso Luiza« and »[[ ]]«


Removed for correction

  • Nov-30 Mo
O2k-Open SupportInfo: improve Noisy oxygen signal? Check the OroboPOS and OroboPOS-Connector to clean electrical connections.

Contaminating grease, salt crystals and moisture can be removed with a dry paper cloth or a paper cloth moistened with water and then absolute ethanol.
- »Cleaning the electrical connections« 
- communicated by »Schmitt Sabine« and »Komlodi Timea«

WGT recommended not to use water for cleaning. Erich introduced water for cleaning to remove salt crystals.


O2k-Open SupportWarning: loss of data Do you perform the leaky chamber test after chamber assembly?

An unnoticed leak from the chamber may affect your data, therefore we recommend performing the Leaky chamber test - especially after chamber reassembly.
- »Leaky chamber test« and » https://intern.oroboros.at/index.php/Overnight_test_after_O2k-chamber_assembly«