Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "MiPNet14.06 Instrumental O2 background"

From Bioblast
 
(150 intermediate revisions by 26 users not shown)
Line 1: Line 1:
{{Template:OROBOROS support page name}}
{{Publication
{{Publication
|title=Fasching M, Gnaiger E. Instrumental background correction and accuracy of oxygen flux. '''''Mitochondr. Physiol. Network'' 14.6'''.
|title=[[Image:O2k-Manual.jpg|right|70px|link=O2k-Manual|O2k-Manual]] O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux.
|authors=Fasching M, Gnaiger E
|info=[[File:PDF.jpg|100px|link=http://wiki.oroboros.at/images/6/65/MiPNet14.06_InstrumentalO2Background.pdf |Bioblast pdf]] » [http://www.bioblast.at/index.php/File:MiPNet14.06_InstrumentalO2Background.pdf Versions]
|year=*
|authors=Oroboros
|journal=Mitochondr. Physiol. Network
|year=2023-10-19
|mipnetlab=AT Innsbruck OROBOROS
|journal=Mitochondr Physiol Network
|abstract=For calibration of the polarographic oxygen sensor (POS) and for measurement of instrumental background oxygen consumption, only incubation medium but no biological sample is added into the Oxygraph-2k chamber, at experimental conditions. In a closed chamber under these conditions, ideally oxygen concentration remains constant. In practice, however, instrumental background effects are caused by back-diffusion into the oxygraph chamber at low oxygen pressure, oxygen diffusion out of the oxygraph chamber at elevated oxygen levels, and oxygen consumption by the polarographic oxygen sensor (POS). Instrumental background interferes with accurate measurement of respiratory oxygen flux, if background effects remain undefined. Determination of instrumental background constitutes an important standard operating procedure (SOP) in high-resolution respirometry (HRR) Instrumental background oxygen flux is (i) minimized in the OROBOROS Oxygraph-2k by instrumental design and selection of appropriate materials. In addition, (ii) instrumenal background is routinely tested, and (iii) background correction of oxygen flux is applied automatically by DatLab.
|abstract=Timón-Gómez A, Grings M, Baglivo E, Schmitt S, Gnaiger E (2023) O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux. Mitochondr Physiol Network 14.6(09):1-16.
|keywords=Instrumental background
{{MiPNet pdf page linking to MitoPedia}}
|info=[http://www.oroboros.at/index.php?id=backgroundcorrection www.oroboros.at/Standard Operating Procedures]
:» Product: [[O2k-FluoRespirometer]], [[Oroboros O2k-Catalogue |O2k-Catalogue]]
}}
|mipnetlab=AT_Innsbruck_Oroboros
{{Labeling
|discipline=Mitochondrial Physiology
|instruments=Oxygraph-2k, Theory
|articletype=Protocol; Manual, MiPNet-online Publication
}}
}}


==Info==
== Keywords ==
{{Template:Keywords: Chamber volume}}
 
 
 


MiPNet10.07 is integrated in MiPNet14.06.
'''Acknowledgements'''
[[File:Template NextGen-O2k.jpg|left|400px|link=NextGen-O2k]]
<br/>
<br/>
<br/>
<br/>


[[Category:OroboroPedia]]
{{Labeling
|area=Respiration, Instruments;methods
|instruments=Oxygraph-2k, O2k-Manual
|additional=DatLab, O2k-SOP, DL7, System, MitoFit2022QC
}}

Latest revision as of 17:19, 19 October 2023


                  


O2k-Open Support

MiPNet14.06 Instrumental O2 background


Publications in the MiPMap
O2k-Manual
O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux.

» Bioblast pdf » Versions

Oroboros (2023-10-19) Mitochondr Physiol Network

Abstract: Timón-Gómez A, Grings M, Baglivo E, Schmitt S, Gnaiger E (2023) O2k Quality Control 2: Instrumental oxygen background correction and accuracy of oxygen flux. Mitochondr Physiol Network 14.6(09):1-16.

O2k-technical support and open innovation
Open the pdf document above.
» Current O2k-series: NextGen-O2k Series XB and O2k Series J
» Current software versions DatLab 8.0: MitoPedia: DatLab
» Product: O2k-FluoRespirometer, O2k-Catalogue


O2k-Network Lab: AT_Innsbruck_Oroboros


Keywords


Questions.jpg


Click to expand or collaps




Acknowledgements

Template NextGen-O2k.jpg






Labels: MiParea: Respiration, Instruments;methods 





HRR: Oxygraph-2k, O2k-Manual 

DatLab, O2k-SOP, DL7, System, MitoFit2022QC