Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "MiPNet19.18D O2k-Series G and DatLab 6: Calibration"

From Bioblast
 
(107 intermediate revisions by 16 users not shown)
Line 1: Line 1:
{{OROBOROS header page name}}
{{Publication
{{Publication
|title=Gnaiger E. Oxygen and pX Calibration DatLab4.3. Mitochondr. Physiol. Network 12.08.
|title=[[Image:O2k-Protocols.jpg|right|80px|link=O2k-Protocols|O2k-Protocols]] O2k-calibration by DatLab 6.
|info=[http://www.oroboros.at/index.php?id=o2k-o2calibration  MiPNet12.08]
|info=[[File:PDF.jpg|100px|link=http://wiki.oroboros.at/images/a/ab/MiPNet19.18D_O2k-Calibration.pdf |Bioblast pdf]] »[http://www.bioblast.at/index.php/File:MiPNet19.18D_O2k-Calibration.pdf Versions]
|authors=Gnaiger E
|authors=Oroboros
|year=*
|year=2016-08-24
|journal=Mitochondr. Physiol. Network
|journal=Mitochondr Physiol Network
|abstract=Accurate calibration of the oxygen sensor depends on (1)
|abstract=Gnaiger E (2016) Oxygen calibration by DatLab 6. Mitochondr Physiol Network 19.18(D04):01-12. »
calibration solutions prepared at known oxygen partial pressures, as
[[Image:MitoPedia.jpg|left|60px|link=http://www.bioblast.at/index.php/MitoPedia: DatLab|MitoPedia: DatLab]] [[O2 calibration - DatLab]]
achieved in the Oxygraph-2k (O2k) at defined temperature, continuously
{{MiPNet pdf page linking to MitoPedia}}
recorded total gas pressure (barometric pressure), and thermodynamic
|keywords=
equilibrium between the gas and aqueous phase; (2) high stability of the
|mipnetlab=AT_Innsbruck_Oroboros
signal of the polarographic oxygen sensor (POS), tested for sufficiently
long periods of time; (3) linearity of signal output with oxygen pressure,
achieved with the POS in the range between oxygen saturation and zero
oxygen pressure; and (4) application of accurate oxygen solubilities for
aqueous solutions for the conversion of partial oxygen pressure into
oxygen concentration [[MiPNet06.03]]. The standard oxygen calibration
procedure is described for O2k high-resolution respirometry with the
automatic calibration routine of DatLab 4.
|keywords=HRR-DatLab
|mipnetlab=AT_Innsbruck_OROBOROS
|articletype=Protocol; Manual, MiPNet-online Publication
}}
}}
{{Template:Keywords: Oxygen signal}}
{{Labeling
{{Labeling
|instruments=Oxygraph-2k, O2k-Manual, MiPNet-Publication
|area=Instruments;methods
|articletype=Protocol; Manual, MiPNet-online Publication
|instruments=Oxygraph-2k
|additional=O2k-Core, DatLab, DL6
}}
}}
==Info==
MiPNet08.07, MiPNet09.08 and MiPNet02.01 (DatLab 2) is integrated into MiPNet12.08.

Latest revision as of 08:47, 29 January 2020

                



MiPNet19.18D O2k-Series G and DatLab 6: Calibration

Publications in the MiPMap
O2k-Protocols
O2k-calibration by DatLab 6.

» Bioblast pdf »Versions

Oroboros (2016-08-24) Mitochondr Physiol Network

Abstract: Gnaiger E (2016) Oxygen calibration by DatLab 6. Mitochondr Physiol Network 19.18(D04):01-12. »

MitoPedia: DatLab

O2 calibration - DatLab


O2k-technical support and open innovation
Open the pdf document above.
» Current O2k-series: NextGen-O2k Series XB and O2k Series J
» Current software versions DatLab 8.0: MitoPedia: DatLab


O2k-Network Lab: AT_Innsbruck_Oroboros



Questions.jpg


Click to expand or collaps



Labels: MiParea: Instruments;methods 





HRR: Oxygraph-2k 

O2k-Core, DatLab, DL6