Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "SUIT-003 O2 ce D037"

From Bioblast
Line 10: Line 10:
::: '''[[SUIT protocol pattern]]:''' complex cell [[coupling control protocol]] ce1;ce2Glc;ce3U
::: '''[[SUIT protocol pattern]]:''' complex cell [[coupling control protocol]] ce1;ce2Glc;ce3U


SUIT-003 O2 ce D037 has been designed to study the [[coupling control state]] and respiration regulation by glucose (Crabtree effect) on intact cells. The different capacities are tested in the sequence [[OXPHOS]] and [[ET]]. SUIT-003 O2 ce D037 follows a modular approach and can be easily used in combination with the assessment of complex IV capacity and respirometric cell viability test.
SUIT-003 O2 ce D037 has been designed to study the [[coupling control state]] and respiration regulation by glucose (Crabtree effect) of intact cells on [[ROUTINE]] control state. The different capacities are tested in the sequence [[OXPHOS]] and [[ET]]. SUIT-003 O2 ce D037 follows a modular approach and can be easily used in combination with the assessment of complex IV capacity and respirometric cell viability test.




Line 28: Line 28:
::::* [[SUIT-003 O2 ce-pce D013]]
::::* [[SUIT-003 O2 ce-pce D013]]
::::* [[SUIT-003 O2 ce-pce D018]]
::::* [[SUIT-003 O2 ce-pce D018]]
::::* [[SUIT-003 O2 ce D038]]


== References ==
== References ==

Revision as of 18:05, 26 March 2019


high-resolution terminology - matching measurements at high-resolution


SUIT-003 O2 ce D037

Description

Ce1;ce2Glc;ce3U-.png

Abbreviation: ceGlc

Reference: A Coupling control protocol and Crabtree effect test -SUIT-003

SUIT number: D037_ce1;ce2Glc;ce3U

O2k-Application: O2

MitoPedia: SUIT
SUIT-category: ceGlc
SUIT protocol pattern: complex cell coupling control protocol ce1;ce2Glc;ce3U

SUIT-003 O2 ce D037 has been designed to study the coupling control state and respiration regulation by glucose (Crabtree effect) of intact cells on ROUTINE control state. The different capacities are tested in the sequence OXPHOS and ET. SUIT-003 O2 ce D037 follows a modular approach and can be easily used in combination with the assessment of complex IV capacity and respirometric cell viability test.


MitoPedia: SUIT

Steps and respiratory states

Ce1;ce1Glc;ce2(Omy);ce3U;ce4Ama.png

Step State Pathway Q-junction Comment - Events (E) and Marks (M)
ce1 ROUTINE ce1
  • ROUTINE respiration in the physiological coupling state R. Externally added permeable substrates could contribute to this respiratory state.
ce1Glc ROUTINE ce1;ce1Glc
  • ROUTINE respiration in the physiological coupling state R. Externally added permeable substrates could contribute to this respiratory state.
  • Glucose is added to test Crabtree effect.
(ce2Omy) L(Omy) ce1;ce1Glc;(ce2Omy)
  • Non-phosphorylating resting state (LEAK state); LEAK-respiration, L(Omy), after blocking the ATP synthase with oligomycin.
  • If the aim is to analyse only Crabtree effect, it is recommended to skip this step. However, if there is also interest in studying coupling control, Omy can be added at this point to reach LEAK.
ce3U E ce1;ce1Glc;(ce2Omy);ce3U
ce4Ama ROX ce1;ce1Glc;(ce2Omy);ce3U;ce4Ama
  • Rox is the residual oxygen consumption in the ROX state, due to oxidative side reactions, estimated either after inhibition of CIII (e.g. antimycin A, myxothiazol), CIV (e.g. Cyanide) or in the absence of endogenous fuel-substrates. Rox is subtracted from oxygen flux as a baseline for all respiratory states, to obtain mitochondrial respiration.


Questions.jpg


Click to expand or collaps

Strengths and limitations

  • The SUIT-003 O2 ce D037 is a cell coupling control protocol. The total cell count (Nce) is the sum of viable cells (Nvce) and dead cells (Ndce).
  • This protocol can be extended with the cell viability test module (See CCV SUIT-003 O2 ce-pce D020).
  • CIV activity can also be measured after the cell viability test module.
+ Reasonable duration of the experiment.
- Cell culture media with glucose (e.g. DMEM: 25 µM Glucose) could hinder the cell viability test.
- Careful washing is required after the experiment to avoid carry-over of inhibitors and uncoupler.

Compare SUIT protocols

References

MitoPedia concepts: SUIT protocol, SUIT A, Find 


MitoPedia methods: Respirometry