|description='''Stirrer-Bar sV\white [[PVDF]]\11.5x6.2 mm''', operated in the [[O2k-Chamber sV]] at constant stirring speed (standard is 750 rpm, or 12.5 Hz), to provide optimum mixing of the sample in the aqueous medium and ensure a stable signal of the polarographic oxygen sensor ([[OroboPOS]]) placed in a position of maximum current of the medium.
__TOC__
{{MitoPedia without banner
|abbr=
|description=[[File:33210-01.jpg|right|180px]]'''Stirrer-Bar sV\white [[PVDF]]\11.5x6.2 mm''', operated in the 0.5-mL [[O2k-Chamber sV]] at constant stirring speed (standard is 750 rpm, or 12.5 Hz), to provide optimum mixing of the sample in the aqueous medium and ensure a stable signal of the polarographic oxygen sensor ([[OroboPOS]]) placed in a position of maximum current of the medium.


Two units of this item are standard components of the [[O2k-Chamber sV]].
|info=[https://www.oroboros.at/index.php/product/stirrer-bar-svwhite-pvdf11-5x6-2-mm/ '''Product details and purchase information''']


|product id=33210-01
|product type=O2k, O2k-sV-Module
|info
|product image=[[File:33210-01.jpg|right|180px]]
}}
}}
== Technical support ==
:::* A "jumping" stirring bar problem is frequently caused by small particles sticking to the glass chamber, not the stirring bar itself.
::::» [[MiPNet19.03 O2k-cleaning and ISS]].
== Keywords ==
{{Template:Keywords: Chamber volume}}




<!--
CHECK THE TEXT BELOW


* For dispatch of the [[O2k-Chamber sV]], the Stirrer-Bars sV are shipped in the [[Storage box sV]].


A "jumping" stirring bar problem is frequently caused by small particles sticking to the glass chamber, not the stirring bar itself. >> [[MiPNet19.03 O2k-cleaning and ISS]]. -->
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry
}}

Latest revision as of 10:15, 11 November 2020


                  


O2k-Open Support

Stirrer-Bar sV\white PVDF\11.5x6.2 mm



Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Description

33210-01.jpg

Stirrer-Bar sV\white PVDF\11.5x6.2 mm, operated in the 0.5-mL O2k-Chamber sV at constant stirring speed (standard is 750 rpm, or 12.5 Hz), to provide optimum mixing of the sample in the aqueous medium and ensure a stable signal of the polarographic oxygen sensor (OroboPOS) placed in a position of maximum current of the medium.


Reference: Product details and purchase information

Technical support

  • A "jumping" stirring bar problem is frequently caused by small particles sticking to the glass chamber, not the stirring bar itself.
» MiPNet19.03 O2k-cleaning and ISS.