Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Template:Keywords: Coupling control"

From Bioblast
(Replaced content with "{{Template:Coupling-control tables}} <br /> left|40px <br /> right|45px |Click to expand or collaps <div class="toccolours mw-co...")
Tag: Replaced
 
Line 8: Line 8:
<div class="mw-collapsible-content">
<div class="mw-collapsible-content">
__TOC__
__TOC__
=== Mitochondrial and cellular respiratory rates in coupling-control states ===
{{Template:Keywords: Coupling control states and rates}}
[[Image:OXPHOS-coupled energy cycles.jpg|right|300px||link=Gnaiger 2020 BEC MitoPathways|OXPHOS-coupled energy cycles. Source: The Blue Book]]
::::» [[Baseline state]]
{| class="wikitable"
|-
! Respiratory rate !! Defining relations !! Icon
|-
| [[OXPHOS capacity]] || ''P'' = ''P´''-''Rox'' || [[File:P.jpg |link=OXPHOS capacity]] || mt-preparations
|-
| [[ROUTINE respiration]] || ''R'' = ''R´''-''Rox'' || [[File:R.jpg |link=ROUTINE respiration]] || living cells
|-
| [[ET capacity]] || ''E'' = ''E´''-''Rox'' || [[File:E.jpg |link=ET capacity]] || » [[Level flow]]
|-
|  ||  ||  || » [[Noncoupled respiration]] - [[Uncoupler]]
|-
| [[LEAK respiration]] || ''L'' = ''L´''-''Rox'' || [[File:L.jpg |link=LEAK respiration]] || » [[Static head]]
|-
|  ||  ||  || » [[LEAK state with ATP]]
|-
|  ||  ||  || » [[LEAK state with oligomycin]]
|-
|  ||  ||  || » [[LEAK state without adenylates]]
|-
| [[Residual oxygen consumption]] ''Rox'' || ''L'' = ''L´''-''Rox'' || [[File:ROX.jpg |link=Residual oxygen consumption]]
|}
 
:::* Chance and Williams nomenclature: respiratory states
::::» [[State 1]] —» [[State 2]] —» [[State 3]] —» [[State 4]] —» [[State 5]]
 
=== Flux control ratios related to coupling in mt-preparations and living cells ===
::::» [[Flux control ratio]]
::::» [[Coupling-control ratio]]
::::» [[Coupling-control protocol]]
 
{| class="wikitable"
|-
! ''FCR'' !! Definition !! Icon
|-
| [[L/P coupling-control ratio |''L/P'' coupling-control ratio]] || ''L/P'' || [[Image:L over P.jpg|50 px|link=L/P coupling-control ratio |''L/P'' coupling-control ratio]] || » [[Respiratory acceptor control ratio]], RCR = ''P/L''
|-
| [[L/R coupling-control ratio |''L/R'' coupling-control ratio]] || ''L/R'' || [[Image:L over R.jpg|50 px|link=L/R coupling-control ratio |''L/R'' coupling-control ratio]]
|-
| [[L/E coupling-control ratio |''L/E'' coupling-control ratio]] || ''L/E'' || [[Image:L over E.jpg|50 px|link=L/E coupling-control ratio |''L/E'' coupling-control ratio]] || » [[Uncoupling-control ratio]], UCR = ''E/L'' (ambiguous)
|-
| [[P/E control ratio |''P/E'' control ratio]] || ''P/E'' || [[Image:P over E.jpg|50 px|link=P/E control ratio |''P/E'' control ratio]]
|-
| [[R/E control ratio |''R/E'' control ratio]] || ''R/E'' || [[Image:R over E.jpg|50 px|link=R/E control ratio |''R/E'' control ratio]] || » [[Uncoupling-control ratio]], UCR = ''E/L''
|-
| [[net P/E control ratio |net ''P/E'' control ratio]] || (''P-L'')/''E'' || [[Image:NetP over E.jpg|60 px|link=net P/E control ratio |net ''P/E'' control ratio]]
|-
| [[net R/E control ratio |net ''R/E'' control ratio]] || (''R-L'')/''E'' || [[Image:NetR over E.jpg|60 px|link=net R/E control ratio |net ''R/E'' control ratio]]
|}
 
=== Net, excess, and reserve capacities of respiration ===
{| class="wikitable"
|-
! Respiratory net rate !! Definition !! Icon
|-
| [[P-L net OXPHOS capacity |''P-L'' net OXPHOS capacity ]] || ''P-L'' || [[Image:P-L.jpg|50 px|link=P-L net OXPHOS capacity |''P-L'' net OXPHOS  capacity]]
|-
| [[R-L net ROUTINE capacity |''R-L'' net ROUTINE capacity]] || ''R-L'' || [[Image:R-L.jpg|50 px|link=R-L net ROUTINE capacity |''R-L'' net ROUTINE capacity]]
|-
| [[E-L net ET capacity |''E-L'' net ET capacity]] || ''E-L'' || [[Image:E-L.jpg|50 px|link=E-L net ET capacity |''E-L'' net ET capacity]]
|-
| [[E-P excess capacity |''E-P'' excess capacity]] || ''E-P'' || [[Image:E-P.jpg|60 px|link=E-P excess capacity |''E-P'' excess capacity]]
|-
| [[E-R reserve capacity |''E-R'' reserve capacity]] || ''E-R'' || [[Image:E-R.jpg|60 px|E-R reserve capacity |''E-R'' reserve capacity]]
|}
 
=== Flux control efficiencies related to coupling-control ratios ===
::::» [[Flux control efficiency]] ''j<sub>Z-Y</sub>''
::::» [[Background state]]
::::» [[Reference state]]
::::» [[Metabolic control variable]]
 
{| class="wikitable"
|-
! Coupling-control efficiency !!  !! Definition !!  !! Icon !! Canonical term
|-
| [[P-L control efficiency |''P-L'' control efficiency]] || ''j<sub>P-L</sub>'' || = (''P-L'')/''P'' || = 1-''L/P'' || [[Image:j(P-L).jpg|50 px|link=P-L control efficiency |''P-L'' control efficiency]] || ''P-L'' OXPHOS-flux control efficiency
|-
| [[R-L control efficiency |''R-L'' control efficiency]] || ''j<sub>R-L</sub>'' || = (''R-L'')/''R'' || = 1-''L/R'' || [[Image:j(R-L).jpg|50 px|link=R-L control efficiency |''R-L'' control efficiency]] || ''R-L'' ROUTINE-flux control efficiency
|-
| [[E-L coupling efficiency |''E-L'' coupling efficiency]] || ''j<sub>E-L</sub>'' || = (''E-L'')/''E'' || = 1-''L/E'' || [[Image:j(E-L).jpg|50 px|link=E-L coupling efficiency |''E-L'' coupling efficiency]] || ''E-L'' ET-coupling efficiency » [[Biochemical coupling efficiency]]
|-
| [[E-P control efficiency |''E-P'' control efficiency]] || ''j<sub>E-P</sub>'' || = (''E-P'')/''E'' || = ''1-''P/E'' || [[Image:j(E-P).jpg|50 px|link=E-P control efficiency |''E-P'' control efficiency]] || ''E-P'' ET-excess flux control efficiency
|-
| [[E-R control efficiency |''E-R'' control efficiency]] || ''j<sub>E-R</sub>'' || = (''E-R'')/''E'' || = 1-''R/E'' || [[Image:J(E-R).jpg|50 px|link=E-R control efficiency |''E-R'' control efficiency]] || ''E-R'' ET-reserve flux control efficiency
|}
 
=== General ===
::::» [[Basal respiration]]
::::» [[Cell ergometry]]
::::» [[Dyscoupled respiration]]
::::» [[Dyscoupling]]
::::» [[Electron leak]]
::::» [[Electron-transfer-pathway state]]
::::» [[Hyphenation]]
::::» [[Oxidative phosphorylation]]
::::» [[Oxygen flow]]
::::» [[Oxygen flux]]
::::» [[Permeabilized cells]]
::::» [[Phosphorylation system]]
::::» [[Proton leak]]
::::» [[Proton slip]]
::::» [[Respiratory state]]
::::» [[Uncoupling]]
</div>
</div>
<br />
 
[[Category:Keywords]]
[[Category:Keywords]]

Latest revision as of 11:55, 28 May 2022


Questions.jpg


Click to expand or collaps
Bioblast links: Coupling control - >>>>>>> - Click on [Expand] or [Collapse] - >>>>>>>

1. Mitochondrial and cellular respiratory rates in coupling-control states

OXPHOS-coupled energy cycles. Source: The Blue Book
» Baseline state
Respiratory rate Defining relations Icon
OXPHOS capacity P = -Rox P.jpg mt-preparations
ROUTINE respiration R = -Rox R.jpg living cells
ET capacity E = -Rox E.jpg » Level flow
» Noncoupled respiration - Uncoupler
LEAK respiration L = -Rox L.jpg » Static head
» LEAK state with ATP
» LEAK state with oligomycin
» LEAK state without adenylates
Residual oxygen consumption Rox L = -Rox ROX.jpg
  • Chance and Williams nomenclature: respiratory states
» State 1 —» State 2 —» State 3 —» State 4 —» State 5

2. Flux control ratios related to coupling in mt-preparations and living cells

» Flux control ratio
» Coupling-control ratio
» Coupling-control protocol
FCR Definition Icon
L/P coupling-control ratio L/P L/P coupling-control ratio » Respiratory acceptor control ratio, RCR = P/L
L/R coupling-control ratio L/R L/R coupling-control ratio
L/E coupling-control ratio L/E L/E coupling-control ratio » Uncoupling-control ratio, UCR = E/L (ambiguous)
P/E control ratio P/E P/E control ratio
R/E control ratio R/E R/E control ratio » Uncoupling-control ratio, UCR = E/L
net P/E control ratio (P-L)/E net P/E control ratio
net R/E control ratio (R-L)/E net R/E control ratio

3. Net, excess, and reserve capacities of respiration

Respiratory net rate Definition Icon
P-L net OXPHOS capacity P-L P-L net OXPHOS capacity
R-L net ROUTINE capacity R-L R-L net ROUTINE capacity
E-L net ET capacity E-L E-L net ET capacity
E-P excess capacity E-P E-P excess capacity
E-R reserve capacity E-R E-R reserve capacity

4. Flux control efficiencies related to coupling-control ratios

» Flux control efficiency jZ-Y
» Background state
» Reference state
» Metabolic control variable
Coupling-control efficiency Definition Icon Canonical term
P-L control efficiency jP-L = (P-L)/P = 1-L/P P-L control efficiency P-L OXPHOS-flux control efficiency
R-L control efficiency jR-L = (R-L)/R = 1-L/R R-L control efficiency R-L ROUTINE-flux control efficiency
E-L coupling efficiency jE-L = (E-L)/E = 1-L/E E-L coupling efficiency E-L ET-coupling efficiency » Biochemical coupling efficiency
E-P control efficiency jE-P = (E-P)/E = 1-P/E E-P control efficiency E-P ET-excess flux control efficiency
E-R control efficiency jE-R = (E-R)/E = 1-R/E E-R control efficiency E-R ET-reserve flux control efficiency

5. General

» Basal respiration
» Cell ergometry
» Dyscoupled respiration
» Dyscoupling
» Electron leak
» Electron-transfer-pathway state
» Hyphenation
» Oxidative phosphorylation
» Oxygen flow
» Oxygen flux
» Permeabilized cells
» Phosphorylation system
» Proton leak
» Proton slip
» Respiratory state
» Uncoupling