Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "SUIT-001 O2 ce-pce D004"

From Bioblast
Line 1: Line 1:
{{MitoPedia
{{MitoPedia
|application=O2
|application=O2
|description=[[File:1PM;2D;2c;3U;4G;5S;7Rot;8Gp-.png|400px|SUIT-RP1 for PBMC and PLT]]
|description=[[File:ce1;1PM;2D;2c;3U;4G;5S;7Rot;8Gp-.png|400px|SUIT-RP1 for PBMCs and PLTs]]
|abbr=NSGp(PGM)
|abbr=NSGp(PGM)
|SUIT number=D004_ce1;1Dig;1PM;2D;2c;3U;4G;5S;7Rot;8Gp;9Ama;10AsTm;11Azd  
|SUIT number=D004_ce1;1Dig;1PM;2D;2c;3U;4G;5S;7Rot;8Gp;9Ama;10AsTm;11Azd  
|info='''A: RP1 specific for PBMC and PTL cells''' - [[SUIT-001]]
|info='''A''' Reference protocol RP1 specific for PBMC and PTL cells''' - [[SUIT-001]]
}}
}}
::: [[MitoPedia: SUIT]] - '''[[SUIT reference protocol]] RP1 for PBMCs and PLTs'''
::: [[MitoPedia: SUIT]] - '''[[SUIT reference protocol]] RP1 for PBMCs and PLTs'''
::: '''[[Categories of SUIT protocols|SUIT-category]]:''' NSGp(PGM)
::: '''[[Categories of SUIT protocols|SUIT-category]]:''' NSGp(PGM)
::: '''[[SUIT protocol pattern]]:''' orthogonal 1PM;2D;2c;3U;4G;5S;7Rot;8Gp
::: '''[[SUIT protocol pattern]]:''' orthogonal 1PM;2D;2c;3U;4G;5S;7Rot;8Gp


::::* Reference protocol 1 specifically for PBMCs and PLTs.  
::::* Reference protocol 1 specifically for PBMCs and PLTs.  
Line 15: Line 14:


__TOC__
__TOC__
== Harmonized SUIT protocols ==
'''SUIT RP1 (SUIT-001) for PBMCs and PLTs''' [[File:1PM;2D;2c;3U;4G;5S;6Rot;7Gp;8Ama;9AsTm;10Azd.png|400px|SUIT-RP1 for PBMC and PLT]]
'''SUIT RP2''' (SUIT-002) [[File:1D;2M.1;3Oct;3c;4M2;5P;6G;7S;8Gp;9U;10Rot;11Ama;12AsTm;13Azd.png|500px|SUIT-RP2]]
:::: '''SUIT RP1''':1PM;2D;2c;3U;4G;5S;6Rot;'''7Gp''';8Ama;'''9AsTm''';10Azd
:::: [[1D;2M;3Oct;4M;5P;6G;7S;8Gp;9U;10Rot-|SUIT RP2]]:1D;2M.1;3Oct;3c;4M2;5P;6G;7S;8Gp;9U;'''10Rot''';11Ama;'''12AsTm''';13Azd


== References ==
== References ==
{{#ask:[[Category:Publications]] [[Additional label::SUIT-001 O2 pce D044]]
{{#ask:[[Category:Publications]] [[Additional label::SUIT-001 O2 pce D004]]
| ?Was published in year=Year
| ?Was published in year=Year
| ?Has title=Reference
| ?Has title=Reference
Line 36: Line 27:
| order=descending
| order=descending
}}
}}
{{Template:SUIT-001}}
== Strengths and limitations ==
:::* SUIT-001 in combination with [[SUIT-002]] provides a common reference for comparison of respiratory control in a large variety of species, tissues and cell types. Both SUIT protocols provide a mitochondrial mapping which allows:
:::: 1. to obtain reference values.
:::: 2. to evaluate mitochondrial physiological diversity, generating a mt-database on comparative mitochondrial physiology.
:::: 3. to screen specific defects.
:::* SUIT-001 and [[SUIT-002]] are used in the [[Proficiency_test| MitoFit Proficiency test]] for inter-individual and inter-laboratory reproducibility quality control.
:::* A succinate concentration of >10 mM may be required for saturating S<sub>''E''</sub> capacity.
:::+ Linear coupling control (''L''-''P''-''E'') with N substrates (PM).
:::+ Pathway control in ET state (N, NS, FNS, S and SGp pathways).
:::+ Harmonization with [[SUIT-002]] allows to perform both SUIT protocols in parallel. The cross-linked respiratory states can be statically used as repeat measurements.
:::+ In blood cells, SUIT-001 and SUIT-002 harmonize in: [[ROUTINE]] (ce1), SGp<sub>''E''</sub> (8Gp in SUIT-001 and 10Rot in SUIT-002) and Complex IV.
:::+ Harmonization with many SUIT protocols (up to step 5S).
:::+ This protocol can be extended with the Complex IV module.
:::- The substrate combination for maximum ET capacity (FNSGP) is not obtained in SUIT-001 in favour of measuring S<sub>''E''</sub>.
:::- Oct is not added in ET state.
== Compare SUIT protocols ==
::::* [[SSUIT-2_O2_pce_D07a]] (RP2): Harmonized SUIT protocol for PBMC and PLT cells.
::::* [[SUIT-004]]: Short version of RP1; without G, F and Gp.
::::* [[SUIT-006]]: Very short initial coupling control module.


{{MitoPedia concepts
{{MitoPedia concepts
Line 43: Line 62:
|mitopedia method=Respirometry
|mitopedia method=Respirometry
}}
}}
{{Labeling
|additional=SUIT-001}}
[[Category:Publications]]

Revision as of 13:42, 21 January 2019


high-resolution terminology - matching measurements at high-resolution


SUIT-001 O2 ce-pce D004

Description

SUIT-RP1 for PBMCs and PLTs

Abbreviation: NSGp(PGM)

Reference: A Reference protocol RP1 specific for PBMC and PTL cells - SUIT-001

SUIT number: D004_ce1;1Dig;1PM;2D;2c;3U;4G;5S;7Rot;8Gp;9Ama;10AsTm;11Azd

O2k-Application: O2

MitoPedia: SUIT - SUIT reference protocol RP1 for PBMCs and PLTs
SUIT-category: NSGp(PGM)
SUIT protocol pattern: orthogonal 1PM;2D;2c;3U;4G;5S;7Rot;8Gp
  • Reference protocol 1 specifically for PBMCs and PLTs.
  • The main difference between the RP1 for PBMCs and PLTs and RP1 for other mtprep SUIT RP1 is the absence of Oct in the case of blood cells.

References

MitoPedia: SUIT

Steps and respiratory states

SUIT-001

Step State Pathway Q-junction Comment - Events (E) and Marks (M)
1PM PML(n) N CI 1PM
2D PMP N CI 1PM;2D
2c PMcP N CI 1PM;2D;2c
3U PME N CI 1PM;2D;3U
4G PGME N CI 1PM;2D;3U;4G
5S PGMSE NS CI&II 1PM;2D;3U;4G;5S
  • Respiratory stimulation by simultaneous action of type N substrates & succinate, with convergent electron flow in the NS-pathway for reconstitution of TCA cycle function.
  • Noncoupled electron transfer state, ET state, with ET capacity E.
6Oct OctPGMSE FNS FAO&CI&II 1PM;2D;3U;4G;5S;6Oct
  • Respiratory stimulation by simultaneous action of the F-pathway, N-pathway, and S-pathway, with convergent electron flow in the FNS-pathway for reconstitution of TCA cycle function and additive or inhibitory effect of F.
  • Noncoupled electron transfer state, ET state, with ET capacity E.
7Rot SE S CII 1PM;2D;3U;4G;5S;6Oct;7Rot
8Gp SGpE SGp CII&GpDH 1PM;2D;3U;4G;5S;6Oct;7Rot;8Gp
  • Respiratory stimulation by action of succinate and glycerophosphate, Gp, with convergent electron flow in the SGp-pathway (CII&GpDH-linked pathway to the Q-junction).
  • Noncoupled electron transfer state, ET state, with ET capacity E.
9Ama ROX 1PM;2D;3U;4G;5S;6Oct;7Rot;8Gp;9Ama
  • Rox is the residual oxygen consumption in the ROX state, due to oxidative side reactions, estimated after addition of antimycin A (inhibitor of CIII). Rox is subtracted from oxygen flux as a baseline for all respiratory states, to obtain mitochondrial respiration (mt).
Step Respiratory state Pathway control ET-Complex Comment
## AsTm AsTmE CIV CIV
## Azd CHB


Questions.jpg


Click to expand or collaps

Strengths and limitations

  • SUIT-001 in combination with SUIT-002 provides a common reference for comparison of respiratory control in a large variety of species, tissues and cell types. Both SUIT protocols provide a mitochondrial mapping which allows:
1. to obtain reference values.
2. to evaluate mitochondrial physiological diversity, generating a mt-database on comparative mitochondrial physiology.
3. to screen specific defects.
  • SUIT-001 and SUIT-002 are used in the MitoFit Proficiency test for inter-individual and inter-laboratory reproducibility quality control.
  • A succinate concentration of >10 mM may be required for saturating SE capacity.
+ Linear coupling control (L-P-E) with N substrates (PM).
+ Pathway control in ET state (N, NS, FNS, S and SGp pathways).
+ Harmonization with SUIT-002 allows to perform both SUIT protocols in parallel. The cross-linked respiratory states can be statically used as repeat measurements.
+ In blood cells, SUIT-001 and SUIT-002 harmonize in: ROUTINE (ce1), SGpE (8Gp in SUIT-001 and 10Rot in SUIT-002) and Complex IV.
+ Harmonization with many SUIT protocols (up to step 5S).
+ This protocol can be extended with the Complex IV module.
- The substrate combination for maximum ET capacity (FNSGP) is not obtained in SUIT-001 in favour of measuring SE.
- Oct is not added in ET state.

Compare SUIT protocols

  • SUIT-004: Short version of RP1; without G, F and Gp.
  • SUIT-006: Very short initial coupling control module.


MitoPedia concepts: SUIT protocol, SUIT A, Find 


MitoPedia methods: Respirometry 


Labels:






SUIT-001