Semantic search

From Bioblast
TermDescription
Microbalance 120 g
Microbalance 120 g.jpg

Microbalance max 120 g; 0.01 mg display; particularly for wet weight determination of permeabilized fibres.

Microbalance-Transport Case
Microbalance-Transport Case.jpg

Microbalance transport case, not suitable for shipping

Microsyringe\10 mm3 51/0.13 mm
Hamilton Syringes for Manual Titration.jpg

Hamilton Microsyringe\10 mm3 51/0.13 mm for manual titrations, 10 mm3 volume; fixed injection needle with rounded tip: 51 mm length, 0.13 mm inner diameter.

Microsyringe\100 mm3 51/0.41 mm
Microsyringe 100 mm3 51 0.41 mm - Kopie.JPG

Hamilton Microsyringe\100 mm3 51/0.41 mm for manual titrations, 100 mm3 volume; fixed needle with rounded tip: 51 mm length, 0.41 mm inner diameter. It is recommended for injections of suspensions of isolated mitochondria.

Microsyringe\200 mm3\TIP2k
Microsyringe200 mm3TIP2k.JPG

Microsyringe\200 mm3\TIP2k: Microinjection syringe for Titration-Injection microPump, 200 mm3 (µl), fixed injection needle with rounded tip, with spacers.

Microsyringe\25 mm3 51/0.15 mm
Microsyringe 25 mm3 51 0.15 mm.JPG

Hamilton Microsyringe\25 mm3 51/0.15 mm for manual titrations, 25 mm3 volume; fixed needle with rounded tip: 51 mm length, 0.15 mm inner diameter.

Microsyringe\50 mm3 51/0.15 mm
Microsyringe 100 mm3 51 0.41 mm - Kopie.JPG

Hamilton Microsyringe\50 mm3 51/0.15 mm for manual titrations, 50 mm3 volume; fixed needle with rounded tip: 51 mm length, 0.15 mm inner diameter.

Microsyringe\500 mm3\TIP2k
Microsyringe 500 mm3 TIP2k.JPG

Microsyringe\500 mm3\TIP2k: Microinjection syringe for Titration-Injection microPump, 500 mm3 (µl), fixed injection needle with rounded tip, with spacers.

Microwell respirometry
MitoCom O2k-Fluorometer
MitoCom Workshops
MitoCom lectures
MitoCom2014
MitoEAGLE WG2 Innsbruck AT
MitoEAGLE WG4 Innsbruck AT
MitoFit
MitoFit Conference 2019 Innsbruck AT
MitoFit DOI Data CenterThe MitoFit DOI Data Center is responsible for the provision of digital identifiers, for the storage and ensuring the persistence of the scientific objects, the provision of access, review process and maintenance of the Metadata, and quality control.
MitoFit Deutsch
MitoFit K-Regio project report
MitoFit Open Seminar 2017-07-14
MitoFit Open Seminar 2017-10-23
MitoFit Open Seminars
MitoFit Prep
MitoFit Preprints
MitoFit Preprints.png

MitoFit Preprints is an Open Access preprint server for mitochondrial physiology and bioenergetics.

MitoFit SC 2016 Participants and abstracts
MitoFit Science Camp 2016 Kuehtai AT
MitoFit Workshop ATP 2017 Innsbruck AT
MitoFit Workshop Blood Cells 2016-01-08
MitoFit Workshop en.co.tec medical device 2016-02-04
MitoFit news
MitoFit-Bloodcells
MitoFit-KMP
MitoFit-Medical device
MitoFit-Physiotherapy module
MitoFit-QCS
MitoFit-Reference sample
MitoFit-Sport module
MitoFit-Training module
MitoGlobalPlayer invitation HRR
MitoKIN
MitoKit-CII
MITOKIT-CII.jpg

Cell permeable prodrugs, composed of MitoKit-CII/Succinate-nv and MitoKit-CII/Malonate-nv, stimulates (Snv) or inhibits (Mnanv) mitochondrial respiration in CI-deficient human blood cells, fibroblasts and heart fibres, acting on Complex II of the electron transfer system.

MitoPedia: DatLab
MitoPedia: Gentle Science
MitoPedia: O2k
MitoPedia: O2k hardware
MitoPedia: O2k-FluoRespirometry
MitoPedia: O2k-Open Support
MitoPedia: O2k-Respirometry
MitoPedia: Oroboros QM
MitoPedia: Preprints
MitoPedia: SUIT
Mitochondira in Health and Disease 2017 NY US
Mitochondr Physiol Network
Mitochondrial Medicine 2018 Hinxton UK
Mitochondrial Medicine 2019 Zurich CH
Mitochondrial Physiology ‐ from Organelle to Organism 2019 Copenhagen DK
Mitochondrial membrane potential

The mitochondrial membrane potential difference, mtMP or ΔΨp+ = ΔelFep+, is the electric part of the protonmotive force, Δp = ΔmFeH+.

ΔelFep+ = ΔmFeH+ - ΔdFeH+
ΔΨp+ = Δp - ΔµH+·(zH+·F)-1

ΔΨp+ is the potential difference across the mitochondrial inner membrane (mtIM), expressed in the electric unit of volt [V]. Electric force of the mitochondrial membrane potential is the electric energy change per ‘motive’ charge or per charge moved across the transmembrane potential difference, with the number of ‘motive’ charges expressed in the unit coulomb [C].

Molina Anthony JA
Monte Rosa
Moore Anthony L
More O2k-Feedback
Moreno-Sanchez 2022 MitoFit
Morosinotto Tomas
Motic Microscope
Motic Microscope.jpg

Motic Microscope SMZ-171 TLED: for preparation of permeabilized fibres; compact and light stereo microscope, Greenough optical system, switching power supply for use worldwide (100-240V); including auxiliary ESD objective 2.0X(38.6mm).

Mouse control: Mark

The mark mode is active by default, can be selected in the menu or by [Ctrl+M]. If Mouse control: Mark is enabled, specific sections of the experiment can be marked in each plot. Usually, marks are set on the plot for oxygen concentration for calibration, whereas marks on the plot for oxygen flux are set for exporting the median or average of flux to a table.

»More details: Marks - DatLab.

Mouse control: ZoomSelect Mouse Control: Zoom in the Graph-menu or press [Ctrl+Z].
Movement and Cognition 2018 MA US
Movement and Cognition 2019 Tel-Aviv IL
Movement and Cognition 2020 Paris FR
MtFOIE GRAS
MultiSensor-Connector
30420-24 MultiSensorConnector.JPG

MultiSensor-Connector: for separate reference electrode and ISE; only for O2k-Series B and Series C with MultiSensor electronic upgrading before 2011.

MultiSensor-Preamplifier 1/100
30430--24 NO-Attachment.JPG

MultiSensor-Preamplifier 1/100: Required only for O2k-Series A-C, for application of NO (or other amperometric) sensors (single chamber mode of application).

Mutschler 2022 MitoFit
NADH calibration - DatLabNADH calibration
NADH-Module
NADH-Module - 12700-01.jpg

The NADH-Module, is a component of the NextGen-O2k for simultaneous measurement of oxygen consumption and NAD(P)H autofluorescence. NAD(P)H autofluorescence is used to evaluate the redox state of the NAD(P)H-pool. The NADH-Module incorporates an UV light and NADH-Sensors which include a photodiode and specific filters.

NADH-Sensor
NADH sesnor 003.png

The NADH-Sensor has been developed as a part of the NADH-Module for simultaneous monitoring of oxygen consumption and NADH redox state. The NADH-Sensor is composed of a photodiode and equipped with three supergel R370 Italian blue filters (Rosco, US).

NHLBI Mitochondrial Biology Symposium 2019 Bethesda US
NL Amsterdam Nollet E
NL Amsterdam Serlie MJ
NL Amsterdam Wuest RC
NL Eindhoven Nicolay K
NL Groningen Reijngoud RJ
NL Leiden Lindeman JHN
NL Maastricht Bierau J
NL Maastricht Schrauwen P
NL Nijmegen Brandt U
NL Nijmegen Koopman WJH
NL Nijmegen Radboud University Nijmegen Medical Centre
NL Nijmegen Rodenburg R
NL Rotterdam Schoonderwoerd KGC
NL Rotterdam Sluiter W
NL Wageningen Keijer J
NO As Egelandsdal B
NO Bergen Berge RK
NO Bergen Tronstad KJ
NO Bergen Univ Bergen
NO Matredal Olsen RE
NO Oslo Eide L
NO Tromsoe Ingebretsen OC
NO Tromsoe Larsen TS
NO Tromsoe Wood SH
NO Trondheim Grill V
NO Trondheim Hoydal MA
NZ Auckland GBC BioMed
NZ Auckland Hickey AJ
NZ Auckland Pham T
NZ Auckland Ward ML
Nature Conference 2019 Xiamen CN
Neurocon 2019 Haryana IN
NextGen-O2k
NextGen-O2k Dissemination
NextGen-O2k Documentation
NextGen-O2k Exploitation
NextGen-O2k H2020 SME Phase 1
NextGen-O2k Project management
NextGen-O2k SME2 coaching Orily Pratt part 1
NextGen-O2k SME2 coaching Orily Pratt part 2
NextGen-O2k SME2 coaching Samia Kappe part 1
NextGen-O2k Scientific developments
NextGen-O2k Technical developments
Neylon 2017 F1000Research
O-ring sV\Viton\9.5x1 mm
34310-02.jpg

O-ring sV\Viton\9.5x1 mm, for PEEK Stopper sV, 2 are mounted on each PEEK Stopper sV, box of 8 as spares.

O-ring\Viton\12.5x1 mm
O-ringViton12.5x1 mm.jpg

O-ring\Viton\12.5x1 mm, for PVDF or PEEK O2k-Stoppers (2-mL O2k-Chamber), box of 8 as spares.

O-ring\Viton\12x1 mm

O-ring\Viton\12x1 mm, for PVDF or PEEK O2k-Stoppers, box of 4 as spares.

Two spare boxes of this product are standard components of the O2k-Assembly Kit (O2k-FluoRespirometer) as well as the O2k-TPP+ ISE-Module and the O2k-NO Amp-Module.

O-ring\Viton\16x2 mmO-ring\Viton\16x2 mm, mounted on the O2k-Chamber Holder sV.
O-ring\Viton\18x2 mm
Viton O-ring 18x2.jpg

O-ring\Viton\18x2 mm, mounted on the O2k-Chamber Holder.

O-ring\Viton\6x1 mm
POS O-ring for sensor head or POS mounting tool.jpg

O-ring\Viton\6x1 mm for POS-Mounting Tool.

O-ring\Viton\8x1 mm
POS O-ring for sensor head or POS mounting tool.jpg

O-ring\Viton\8x1 mm: for OroboPOS sensor head. Replaces the

O-ring\Viton\9x1 mm

O2 background correction - DatLab
O2-Zero Powder
O2-Zero Powder.jpg

O2-Zero Powder, dithionite (Na2S2O4), for zero-oxygen calibration of the OroboPOS.

O2k Applications
O2k On-site Training
O2k chamber volume calibrationThe O2k-chamber volume calibration has to be done before getting started with the Oroboros O2k to guarantee a standard chamber volume of 2.0 mL.
O2k channel labelsDefault channel labels can now be changed, and new labels set by the user. E.g., rename the Amperometric channel, Amp, to 'H2O2' for H2O2 measurements by fluorometry; rename the potentiometric channel, pX, to TPP+ for mitochondrial membrane measurements with the O2k-pH ISE-Module. For changing the label, go to menu [Oroboros O2k]\O2k channel labels and set the new channel label as desired.
O2k configuration

Configure or modify the settings for the O2k sensors

In O2k configuration, channels (amperometric and potentiometric) can be switched on/off by selecting the according tick box. The Power-O2k number (P1, P2, ..) and numbers for O2 sensors, Amp sensors, pX electrodes and pX reference electrodes are entered or edited here. With the O2k-FluoRespirometer (O2k-Series H and higher), the serial numbers of the Smart Fluo-Sensors are shown automatically under [Amperometric, Amp]. The O2k configuration window pops up when DatLab starts and "Connect to O2k" is pressed for the first time. It is also accessible from the menu "Oroboros O2k" and from within the O2k control and Mark statistics windows.

O2k controlAfter selection of an O2k setup in the O2k control [F7] window, followed by a left-click Send to O2k, only the following control functions are routinely required during experimental operations.
O2k control panel - DatLabThe O2k control panel allows for quick access of O2k instrument settings. It covers the right side of the graphical user interface of DatLab 8. If a DatLab protocol is active, the protocol panel ist shown instead, a tab at the right side allows to switch between O2k control panel and protocol panel.
O2k repairO2k repair of defective hardware may require replacement of spare parts. Some electronic or mechanical defects may be solved only by repair of the O2k in the electronics workshop of Oroboros Instruments, e.g., a defective Peltier unit (temperature control).
O2k series
The serial number of each O2k is shown on a sticker at the rear of the O2k.

The O2k series is specified as the capital letter in the O2k serial number of the Oroboros O2k. A serial number G-#### or H-#### denotes an Oxygraph from the G or H series, while A-#### denotes an O2k from the A series. With DatLab running real-time connected to the O2k, the serial number of the currently connected O2k is displayed: (1) in the right corner of the status line, besides the DatLab version number (bottom), and (2) in windows O2k control [F7] and O2k configuration.

O2k signal lineThe O2k signal line is underneath the O2k status line. It shows, depending on the O2k series, on the left side the O2k number, the time of the experiment, the oxygen raw signal of each chamber, the block temperature, the barometric pressure, the Peltier power, the recorded amperometric and potentiometric raw signal, the enviromental (room) temperature and the signal from internal sensors recording the humidity and temperature of the electronics. On the right side of the O2k signal line the current user, the DatLab version and the O2k serial number are displayed.
O2k status lineO2k status line is found above the O2k signal line. It contains information about the chamber label, O2 calibration, amperometric calibration, potentiometric calibration, the block temperature, the illumination in chambers, the TIP2k status and the Automatic pan.
O2k-Accessory BoxThe O2k-Accessory Box contains components of the POS-Service Kit and the O2k-Assembly Kit and is shipped with the O2k.
O2k-Amperometric OroboPOS Twin-ChannelO2k-Amperometric OroboPOS Twin-Channel: Two-channel variable polarization voltage; current/voltage converter for the polarographic oxygen sensor (POS); amplifyer with digital gain settings (1x, 2x, 4x, 8x); A/D converter; output in the range -10 V to 10 V. Integral component of the O2k-Main Unit.
O2k-Analysis
O2k-Assembly KitThe O2k-Assembly Kit is a component of the Oroboros O2k, consisting of 2 PVDF Stirrer-Bars, 2 PEEK O2k-Stoppers, OroboPOS-Connectors for O2k-series A-I and NextGen-O2k series XA (attached to the O2k-Main Unit) and cables (power supply, USB-connection). Several components of the O2k-Assembly Kit are included in the O2k-Accessory Box either for shipment or for storage.
O2k-Barometric Pressure TransducerO2k-Barometric Pressure Transducer, A/D converter and digital output to DatLab for continuous recording of barometric pressure [kPa or mmHg], integrated into the air calibration of the POS (MiPNet06.03 POS-calibration-SOP). Integral component of the O2k-Main Unit. The warranty on the accuracy of the signal obtained from the O2k-Barometric Pressure Transducer expires within three years.
O2k-Catalogue: Complete Oroboros Product List
O2k-Catalogue: Microbalance Mettler-Toledo
Microbalance Set.jpg

Microbalance Mettler-Toledo

O2k-Catalogue: O2k-Modules4#### O2k-Catalogue: O2k-Modules. O2k-Modules can be obtained with the O2k or added later, and can be simply installed by the user.
O2k-Catalogue: O2k-Stoppers
O2k-Chamber Holder
Chamber holder PVDF Stopper.jpg

O2k-Chamber Holder (blue POM) for PVDF or PEEK stoppers (2-mL O2k-chamber), with O-ring\Viton\18x2 mm and V-ring\30-35-4.5 mm. Two units of this item are standard components mounted on the O2k-Main Unit.

O2k-Chamber Holder sV
32100-01.jpg

O2k-Chamber Holder sV (black POM) for PVDF or PEEK stoppers (0.5-mL O2k-chamber), with O-ring\Viton\16x2 mm and V-ring\30-35-4.5 mm.

O2k-Chamber sV
33100-01.jpg

O2k-Chamber sV: 12 mm inner diameter, Duran® glass polished, with standard operation volume V of 0.5 mL.

O2k-Chemicals and media
O2k-Coaching Days Innsbruck
O2k-Demo experiments
O2k-Dissection Set
O2k-Dissection-Set.jpg

O2k-Dissection Set: for tissue preparation, set of 4 pairs of stainless steel, antimagnetic forceps and a pair of scissors.

O2k-Electromagnetic Stirrer Twin-ControlO2k-Electromagnetic Stirrer Twin-Control for smooth rotation of the stirrer bars in the two O2k-chambers; with slow-start function to prevent decoupling of the stirrer bar; regulated stirrer speed in the range of 100 to 800 rpm (decoupling may occur at higher stirrer speeds), independent for the two O2k-Chambers; automatic events sent to DatLab when the stirrer is switched on/off or when the rotation seed is changed by the experimenter. Integral component of the O2k-Main Unit.
O2k-Events
O2k-Feedback
O2k-Fluo LED2-Module
Fluorescence-Control Unit lettered.jpg

The O2k-Fluo LED2-Module is a component of the O2k-Fluorometer (O2k-Series D to G). It is an amperometric add-on module to the O2k-Core (O2k-Series D to G), adding a new dimension to high-resolution respirometry. Optical sensors are inserted through the front window of the O2k-glass chambers, for measurement of hydrogen peroxide production (Amplex® UltraRed), ATP production (Magnesium Green™), mt-membrane potential (Safranin, TMRM, Rhodamine 123), Ca2+ (Calcium Green™), and numerous other applications open for O2k-user innovation.

O2k-Fluo Smart-Module

The O2k-Fluo Smart-Module is an amperometric add-on module to the O2k-Respirometer, adding a new dimension to high-resolution respirometry. Optical sensors are inserted through the front window of the O2k-glass chambers, for measurement of hydrogen peroxide production (Amplex® UltraRed), ATP production (Magnesium Green™), mt-membrane potential (Safranin, TMRM), Ca2+ (Calcium Green™), and numerous other applications open for O2k-user innovation.

» MiPNet28.09 O2k-Fluo Smart-Module manual
O2k-FluoRespirometer
O2k-FluoRespirometer

The Oroboros O2k-FluoRespirometer - the experimental system complete for high-resolution respirometry (HRR), including fluorometry, the TIP2k and the O2k-sV-Module allowing simultaneous monitoring of oxygen consumption together with either ROS production (AmR), mt-membrane potential (TMRM, Safranin and Rhodamine 123), Ca2+ (CaG) or ATP production (MgG).

The O2k-FluoRespirometer supports all add-on O2k-Modules: O2k-TPP+ ISE-Module, O2k-pH ISE-Module, O2k-NO Amp-Module, enabling measurement of mt-membrane potential with ion sensitive electrodes (ISE for TPP+ or TPMP+) or pH.

O2k-Fluorometer Series G
O2k-Fluorometer Series G

O2k-Fluorometer Series G - Former Series (up to 2017-July) - the experimental system complete for high-resolution respirometry (HRR) combined with fluorometry. The O2k-Fluorometer includes the O2k-Core, O2k-Fluo LED2-Module and TIP2k, and supports all other add-on O2k-Modules of the Oroboros O2k.

The O2k is a sole source apparatus with no other instruments meeting its test experiments on O2k-Specifications.

O2k-Fuse Power Plug\M2.5 A\5x20 mm
Fuses mains.jpg

O2k-Fuse Power Plug\M2.5 A\5x20 mm: This item is a standard component of the O2k-Assembly Kit (O2k-FluoRespirometer), mounted on the socket for the O2k-Main Power Cable, at the rear panel of the O2k-Main Unit.

O2k-Innovation
O2k-Main Basic

The O2k-Main Basic is an integral element of the O2k-Main Unit. The Oroboros O2k Main Basic has the following components:

  • Stainless-Steel Housing
  • Switching power supply
  • Microprocessor for integrated control, A/D converters and data handling
  • Copper-Block with windows to 2 O2k-Chambers
  • 2 Amperometric OroboPOS Plugs
  • TIP2k socket, providing the basis for add-on of the TIP2k
  • 2 Potentiometric Plugs for ion sensitive electrodes (ISE: TPP+, Ca2+; pH), providing the basis for add-on of the O2k-MultiSensor Modules
  • 2 Amperometric Plugs, providing the basis for add-on of the O2k-Fluo LED2-Module or NO (H2S) sensors.
  • USB-Port for connection with DatLab (PC or laptop not included)
O2k-Main Power CableO2k-Main Power Cable, for connecting the main unit to the power supply.
O2k-Main Power Cable\120 V\US-CA
O2k-Main Power Cable 120 V US-CA.JPG

O2k-Main Power Cable\120 V\US-CA, USA and Canada (120 V).

O2k-Main Power Cable\230 V\AU-NZ
O2k-Main Power Cable 230 V AU-NZ.JPG

O2k-Main Power Cable\AU-NZ, Australia and New Zealand (230 V).

O2k-Main Power Cable\230 V\Europe
O2k-Main Power Cable 230 V Europe.JPG

O2k-Main Power Cable\230 V\Europe.

O2k-Main UnitThe O2k-Main Unit is a component of the O2k-Core. The O2k-Main Unit consists of functionally defined, integral elements, the (O2k-Main Basic, O2k-Peltier Temperature Control, two O2k-Electromagnetic Stirrer Twin-Control units, two O2k-Amperometric OroboPOS Twin-Channels, O2k-Barometric Pressure Transducer), which cannot be obtained separately.
O2k-Manual
O2k-MultiSensorWhen one (or more) analytical parameters are monitored simultaneously with oxygen concentration and oxygen flux, this is an O2k-MultiSensor application of the Oroboros O2k-technology. The NextGen-O2k supports all O2k-MultiSensor Modules, while the O2k does not provide for the Q- and NADH-Redox-Modules. For some O2k-MultiSensor applications it is necessary to introduce one or more additional sensors into the chamber through a MultiSensor stopper. Optical applications require the standard black stoppers.
O2k-NO Amp-Module
O2k-NO Amp-Module.jpg

O2k-NO Amp-Module: NO-sensor compatability pack an amperometric add-on for O2k-MultiSensor application The NO sensor is not included.

O2k-Network
O2k-Network Award
O2k-Network Labs Argentina
O2k-Network Labs Australia
O2k-Network Labs Austria
O2k-Network Labs Belgium
O2k-Network Labs Brazil
O2k-Network Labs Canada
O2k-Network Labs Chile
O2k-Network Labs China
O2k-Network Labs Colombia
O2k-Network Labs Croatia
O2k-Network Labs Cuba
O2k-Network Labs Czech Republic
O2k-Network Labs Denmark
O2k-Network Labs Egypt
O2k-Network Labs Estonia
O2k-Network Labs Finland
O2k-Network Labs France
O2k-Network Labs Germany
O2k-Network Labs Hongkong Region
O2k-Network Labs Hungary
O2k-Network Labs India
O2k-Network Labs Ireland
O2k-Network Labs Israel
O2k-Network Labs Italy
O2k-Network Labs Japan
O2k-Network Labs Latvia
O2k-Network Labs Lithuania
O2k-Network Labs Malaysia
O2k-Network Labs Mexico
O2k-Network Labs Netherlands
O2k-Network Labs New Zealand
O2k-Network Labs Norway
O2k-Network Labs Poland
O2k-Network Labs Portugal
O2k-Network Labs Qatar
O2k-Network Labs Republic of Korea
O2k-Network Labs Republic of Serbia
O2k-Network Labs Romania
O2k-Network Labs Russia
O2k-Network Labs Singapore
O2k-Network Labs Slovak Republic
O2k-Network Labs South Africa
O2k-Network Labs Spain
O2k-Network Labs Sweden
O2k-Network Labs Switzerland
O2k-Network Labs Taiwan
O2k-Network Labs Thailand
O2k-Network Labs Turkey
O2k-Network Labs USA
O2k-Network Labs United Kingdom
O2k-Network Labs Uruguay
O2k-Network Manager India
O2k-Network Manager South Africa
O2k-Network all countries
O2k-Network discussion forum
O2k-Open Support
O2k-Open Support agreementO2k-Open Support aims at providing expert help quickly. Please, help us sharing our support communication openly with the scientific community.
O2k-Open Support alert
O2k-Peltier Temperature ControlO2k-Peltier Temperature Control: Built-in electronic thermostat controlling temperature for two O2k-chambers in the range of 4 to 47 °C; ±0.002 °C (at room temperature). Continuous recording of the O2k-Copper Block temperature with DatLab. Temperature change from 20 to 30 °C within 15 min; cooling from 30 to 20 °C within 20 min. Integral component of the O2k-Main Unit. The electronic temperature control of the O2k replaced the conventional water jacket.
O2k-PowerPoint slides
O2k-Procedures
O2k-Procedures: MitoPathways
O2k-Procedures: Mitochondrial and marker-enzymes
O2k-Products
O2k-Publications
O2k-Publications 1993
O2k-Publications 1994
O2k-Publications 1995
O2k-Publications 1996
O2k-Publications 1997
O2k-Publications 1998
O2k-Publications 1999
O2k-Publications 2000
O2k-Publications 2001
O2k-Publications 2002
O2k-Publications 2003
O2k-Publications 2004
O2k-Publications 2005
O2k-Publications 2006
O2k-Publications 2007
O2k-Publications 2008
O2k-Publications 2009
O2k-Publications 2010
O2k-Publications 2011
O2k-Publications 2012
O2k-Publications 2013
O2k-Publications 2014
O2k-Publications 2015
O2k-Publications 2016
O2k-Publications 2017
O2k-Publications 2018
O2k-Publications 2019
O2k-Publications 2020
O2k-Publications alert
O2k-Publications: ADP
O2k-Publications: ATP production
O2k-Publications: Adenine nucleotide translocase
O2k-Publications: Aerobic glycolysis
O2k-Publications: Aging; senescence
O2k-Publications: Alzheimer's disease
O2k-Publications: Amino acid
O2k-Publications: Amphibians
O2k-Publications: Amplex UltraRed
O2k-Publications: Annelids
O2k-Publications: Archaea
O2k-Publications: Artemia
O2k-Publications: Autism
O2k-Publications: Birds
O2k-Publications: Blood cells
O2k-Publications: Bovines
O2k-Publications: CHO
O2k-Publications: CIV
O2k-Publications: COPD
O2k-Publications: Ca
O2k-Publications: Ca2+ O2k-ISE Module
O2k-Publications: CaG O2k-FluoRespirometer
O2k-Publications: Caenorhabditis elegans
O2k-Publications: Calcium
O2k-Publications: Calcium Green
O2k-Publications: Cancer
O2k-Publications: Cardiovascular diseases
O2k-Publications: Cat
O2k-Publications: Cell death
O2k-Publications: Chicken
O2k-Publications: Chlamydomonas
O2k-Publications: Chloroplasts
O2k-Publications: Comparative MiP;environmental MiP
O2k-Publications: Complex I
O2k-Publications: Complex II;succinate dehydrogenase
O2k-Publications: Complex III
O2k-Publications: Complex IV;cytochrome c oxidase
O2k-Publications: Complex V;ATP synthase
O2k-Publications: Coupling efficiency;uncoupling
O2k-Publications: Crustaceans
O2k-Publications: Cryopreservation
O2k-Publications: Cyt c
O2k-Publications: DQ
O2k-Publications: Diabetes
O2k-Publications: Dog
O2k-Publications: Drosophila
O2k-Publications: ET
O2k-Publications: Endothelial; Epithelial; Mesothelial Cell
O2k-Publications: Enzyme
O2k-Publications: Eubacteria
O2k-Publications: Exercise physiology;nutrition;life style
O2k-Publications: F
O2k-Publications: Fat
O2k-Publications: Fatty acid
O2k-Publications: Fibroblast
O2k-Publications: Fishes
O2k-Publications: Flux control
O2k-Publications: Fungi
O2k-Publications: Genetic knockout; overexpression
O2k-Publications: Genital
O2k-Publications: Gp
O2k-Publications: Guinea pig
O2k-Publications: HEK
O2k-Publications: HUVEC
O2k-Publications: HeLa
O2k-Publications: Heart
O2k-Publications: Hexapods
O2k-Publications: Homogenate
O2k-Publications: Horse
O2k-Publications: Human
O2k-Publications: Human - Heart
O2k-Publications: Human - Skeletal muscle
O2k-Publications: Hypoxia
O2k-Publications: Infectious
O2k-Publications: Inherited
O2k-Publications: Inhibitor
O2k-Publications: Inner mt-membrane transporter
O2k-Publications: Instruments;methods
O2k-Publications: Intact Organ
O2k-Publications: Intact Organism
O2k-Publications: Ion;substrate transport
O2k-Publications: Ischemia-reperfusion
O2k-Publications: Islet Cell; Pancreas; Thymus
O2k-Publications: Isolated Mitochondria
O2k-Publications: Kidney
O2k-Publications: LEAK
O2k-Publications: Leukemia
O2k-Publications: Liver
O2k-Publications: Living cells
O2k-Publications: Lung; gill
O2k-Publications: Lymphocyte
O2k-Publications: Macrophage-derived cell lines
O2k-Publications: Magnesium Green
O2k-Publications: Marker enzyme
O2k-Publications: Mitochondrial disease
O2k-Publications: Mitochondrial diseases and defects
O2k-Publications: Mitochondrial medicine
O2k-Publications: Molluscs
O2k-Publications: Mouse
O2k-Publications: Myopathy
O2k-Publications: N
O2k-Publications: NS
O2k-Publications: Nematodes
O2k-Publications: Nervous system
O2k-Publications: Nervous system-Fatty acid-F-pathway control state
O2k-Publications: Neuroblastoma
O2k-Publications: Neurodegenerative
O2k-Publications: O2k-Fluorometer
O2k-Publications: O2k-Fluorometry
O2k-Publications: O2k-Fluorometry - Fluorophores
O2k-Publications: O2k-NO Amp-Module
O2k-Publications: O2k-Protocol
O2k-Publications: O2k-TPP+ ISE-Module
O2k-Publications: O2k-pH ISE-Module
O2k-Publications: OXPHOS
O2k-Publications: Obesity
O2k-Publications: Other
O2k-Publications: Other cell lines
O2k-Publications: Other combinations
O2k-Publications: Other invertebrates
O2k-Publications: Oxidase; Biochemical Oxidation
O2k-Publications: Oxidases; Biochemical Oxidations
O2k-Publications: Oxygen kinetics
O2k-Publications: Oxygraph-2k
O2k-Publications: PBI-Shredder
O2k-Publications: PBMC
O2k-Publications: PBMCs
O2k-Publications: Parkinson's disease
O2k-Publications: Patients
O2k-Publications: Permeability transition
O2k-Publications: Permeabilized cells
O2k-Publications: Permeabilized tissue
O2k-Publications: Pharmacology;toxicology
O2k-Publications: Photosynthesis
O2k-Publications: Pig
O2k-Publications: Plants
O2k-Publications: Platelets
O2k-Publications: Protists
O2k-Publications: Q-junction effect
O2k-Publications: RONS; Oxidative stress
O2k-Publications: ROUTINE
O2k-Publications: ROX
O2k-Publications: Rabbit
O2k-Publications: Rat
O2k-Publications: Redox state
O2k-Publications: Reptiles
O2k-Publications: S
O2k-Publications: SMP
O2k-Publications: Saccharomyces cerevisiae
O2k-Publications: Separate DatLab Applications
O2k-Publications: Sepsis
O2k-Publications: Skeletal muscle
O2k-Publications: Skeletal muscle - Permeabilized tissue
O2k-Publications: Skeletal muscle - human vs mouse
O2k-Publications: Spectrophotometer
O2k-Publications: Stem cells
O2k-Publications: Substrate
O2k-Publications: Supercomplex
O2k-Publications: TCA cycle and matrix dehydrogenases
O2k-Publications: TIP2k
O2k-Publications: Temperature
O2k-Publications: Temperature: hypothermia; hyperthermia
O2k-Publications: Threshold;excess capacity
O2k-Publications: Tissue normoxia
O2k-Publications: Topics
O2k-Publications: Twin-Flow Respirometry
O2k-Publications: Uncoupler
O2k-Publications: Uncoupling protein
O2k-Publications: Zebrafish
O2k-Publications: mt-Biogenesis;mt-density
O2k-Publications: mt-Membrane potential
O2k-Publications:FAO
O2k-Purchase
O2k-Specifications
O2k-Info.png

O2k versus multiwell respirometer: O2k stands for Oroboros O2k and high-resolution respirometry, meeting powerful quality criteria securing high output and pioneering state-of-the-art comprehensive OXPHOS analysis of substrate control and coupling control of mitochondrial function. 'High throughput' stands for disposable multiwell systems - expensive, with limited scope and extremely high running costs. In respirometry, high throughput is not equivalent to high output. If you’re using a biased instrument, it doesn’t matter how many measurements you take – you’re aiming at the wrong target (Silver 2012 Penguin Press).

O2k-TPP+ ISE-Module
TPP new.jpg

O2k-TPP+ ISE-Module: Potentiometric ion-selective electrodes for measurement of mitochondrial membrane potential

O2k-Titration Set
O2k-Titration Set.JPG

The O2k-Titration Set consists of Hamilton microsyringes (6 x 10 mm3 and 3 spare plungers, 6 x 25 mm3, 1 x 50 mm3, 1 x 100 mm3, 1 x 500 mm3; fixed needles with rounded tips), provided in the Syringe Storage Box with Syringe Labels, a set of two Syringe Racks with Syringe Collars, and a set of two Tube Racks.

O2k-USB Flash Drive
Oroboros-USB-flash-drive.JPG

The O2k-USB Flash Drive is a component of the Oroboros O2k containing: DatLab, O2k-Manual, O2k-Protocols, O2k-Publications, and info on O2k-Workshops.

O2k-Videosupport
O2k-Virtual SupportO2k-Virtual support includes 8 individual hours. Via a live video link, Oroboros experts guide you step-by-step on topics of your choice, such as O2k instrumental setup and service of the polarographic oxygen sensors (POS) for instrumental quality control, an essential component of HRR. This offers the opportunity to analyze and discuss your experimental DatLab files obtained with your O2k with the bioenergetics experts of Oroboros. It offers flexibility to participants and gives the option to choose virtual sessions that best fit individual needs.
O2k-Virtual Support self-study material
O2k-Webinars
O2k-Window Frame
O2k-Window Frame.JPG

O2k-Window Frame: blue POM, with thread for fixation on the O2k-Main Unit, to be removed only for rare cleaning purposes and for front fixation of the Fluorescence-Control Unit, using the O2k-Window Tool.

O2k-Window Tool
O2k-Window Tool.jpg

O2k-Window Tool for removing the blue O2k-Window Frame from the O2k-Main Unit, for rare cleaning purposes and for front fixation of the Fluorescence-Control Unit.

O2k-Workshops
O2k-Workshops in O2k-Network Labs
O2k-brief
O2k-chamber
O2k-Chamber.jpg

O2k-Chamber: Duran® glass polished, with standard operation volumes (V) of 2.0 mL or 0.5 mL (small chamber volume in the O2k-sV-Module, 12 mm inner diameter). The optical properties of Duran® allow application of fluorometric sensors (Duran® optical properties).

O2k-mitochondrial preparations
O2k-pH ISE-Module
PH new.jpg

O2k-pH ISE-Module: two pH electrodes and reference electrodes and accessories

O2k-sV-Module
11200-01.jpg

The O2k-sV-Module is the O2k small-volume module, comprised of two Duran® glass chambers of 12 mm inner diameter specifically developed to perform high-resolution respirometry with reduced amounts of biological sample, and all the components necessary for a smaller operation volume V of 0.5 mL. The current DatLab version is included in the delivery of this revolutionary module.

OROBOROS 1988
OROBOROS 1990
OROBOROS 1991
OROBOROS 1993
OROBOROS 1995
OROBOROS 1999
OROBOROS 2002
OROBOROS 2003
OROBOROS 2005
OROBOROS 2008
OROBOROS 2013
OROBOROS 2014
Oakden-Rayner 2018 Int J Epidemiol
Oncotyrol
Open - DatLabOpen a previously recorded DatLab file.
Open chamberThe term "open O2k-chamber" refers to a situation in which the liquid phase is allowed to equilibrate with a gas phase, but the stopper is partially inserted using the Stopper-Spacer.
Open innovation management
Ophthalmology Conference 2018 Rome IT
OroDM01 Innsbruck AT
OroboPOS
OroboPOS.JPG

The OroboPOS is a polarographic oxygen sensor (POS), with an amperometric mode of operation. The OroboPOS meets the highest quality criteria in terms of linearity, stability and sensitivity of the signal. The Clark type polarographic oxygen sensor (POS) remains the gold standard for measuring dissolved oxygen in biomedical, environmental and industrial applications over a wide dynamic oxygen range.

It consists of a gold cathode, a silver/silverchloride anode and a KCl electrolyte reservoir separated from the sample by a 25 µm membrane (FEP). The main body of the OroboPOS is made of PEEK. With application of a polarization voltage (0.8 V), a current is obtained as an amperometric signal, which is converted to a voltage.

OroboPOS-Connector
POS connector and cable connection.jpg

OroboPOS-Connector (blue POM), with male connection to OroboPOS head (POS) and with cable and male plug fitting into O2k-Main Unit.

OroboPOS-Connector ServiceThe OroboPOS-Connector Service entails routine maintenance and any necessary repairs of the OroboPOS-Connector in the Oroboros electronics workshop (WGT).
OroboPedia topics
Oroboros
Oroboros - our visions
Oroboros 1983
Oroboros 1989
Oroboros 1992
Oroboros 1994
Oroboros 1997
Oroboros 2000
Oroboros 2001
Oroboros 2004
Oroboros 2006
Oroboros 2007
Oroboros 2009
Oroboros 2010
Oroboros 2011